Volumn 36, Issue 7, 2012, Pages 497-506

Simultaneous determination of 25 common pharmaceuticals in whole blood using ultra-performance liquid chromatography-tandem mass spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

ACETIC ACID; ACETONITRILE; AMITRIPTYLINE; ANALGESIC AGENT; ANTIDEPRESSANT AGENT; ANTIHISTAMINIC AGENT; ANTIHYPERTENSIVE AGENT; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; BUTYL ACETATE; CHLORPROTHIXENE; CITALOPRAM; DIBENZEPIN; FLUOXETINE; FORMIC ACID; LAMOTRIGINE; LEVOMEPROMAZINE; LIDOCAINE; METHYLPHENIDATE; METOCLOPRAMIDE; METOPROLOL; MIANSERIN; MIRTAZAPINE; NEUROLEPTIC AGENT; NORFLUOXETINE; NORTRIPTYLINE; ORPHENADRINE; OXYCODONE; PAROXETINE; UNCLASSIFIED DRUG; UNINDEXED DRUG; ZUCLOPENTHIXOL;

EID: 84871097606     PISSN: 01464760     EISSN: 19452403     Source Type: Journal    
DOI: 10.1093/jat/bks054     Document Type: Article
Times cited : (34)

References (25)
  • 1
    • 21344458396 scopus 로고    scopus 로고
    • Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometry
    • Gunnar, T., Ariniemi, K., Lillsunde, P. (2005) Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometry. Journal of Mass Spectrometry, 40, 739-753.
    • (2005) Journal of Mass Spectrometry , vol.40 , pp. 739-753
    • Gunnar, T.1    Ariniemi, K.2    Lillsunde, P.3
  • 2
    • 34547380878 scopus 로고    scopus 로고
    • Bioanalytical procedures for determination of drugs of abuse in blood
    • Kraemer, T., Paul, L. (2007) Bioanalytical procedures for determination of drugs of abuse in blood. Analytical and Bioanalytical Chemistry, 388, 1415-1435.
    • (2007) Analytical and Bioanalytical Chemistry , vol.388 , pp. 1415-1435
    • Kraemer, T.1    Paul, L.2
  • 3
    • 0036131275 scopus 로고    scopus 로고
    • Drugs of abuse monitoring in blood for control of driving under the influence of drugs
    • Moeller, M.R., Kraemer, T. (2002) Drugs of abuse monitoring in blood for control of driving under the influence of drugs. Therapeutic Drug Monitoring, 24, 210-221.
    • (2002) Therapeutic Drug Monitoring , vol.24 , pp. 210-221
    • Moeller, M.R.1    Kraemer, T.2
  • 4
    • 77951257715 scopus 로고    scopus 로고
    • Determination of 19 drugs of abuse and metabolites in whole blood by high-performance liquid chromatography-tandem mass spectrometry
    • Bjørk, M.K., Nielsen, M.K.K, Markussen, L.Ø., Klinke, H.B., Linnet, K. (2010) Determination of 19 drugs of abuse and metabolites in whole blood by high-performance liquid chromatography-tandem mass spectrometry. Analytical and Bioanalytical Chemistry, 396, 2392-2401.
    • (2010) Analytical and Bioanalytical Chemistry , vol.396 , pp. 2392-2401
    • Bjørk, M.K.1    Nielsen, M.K.K.2    Markussen, L.Ø.3    Klinke, H.B.4    Linnet, K.5
  • 5
    • 62549116527 scopus 로고    scopus 로고
    • Simultaneous screening and quantification of 25 opioid drugs in post-mortem blood and urine by liquid chromatography-tandem mass spectrometry
    • Gergov, M., Nokua, P., Vuori, E., Ojanper, I. (2009) Simultaneous screening and quantification of 25 opioid drugs in post-mortem blood and urine by liquid chromatography-tandem mass spectrometry, Forensic Science International, 186, 36-43.
    • (2009) Forensic Science International , vol.186 , pp. 36-43
    • Gergov, M.1    Nokua, P.2    Vuori, E.3    Ojanper, I.4
  • 6
    • 4444230470 scopus 로고    scopus 로고
    • Screening, library-assisted identification and validated quantification of 23 benzodiazepines, flumazenil, zaleplone, zolpidem and zopiclone in plasma by liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization
    • Kratzsch, C., Tenberken, O., Peters, F.T., Weber, A.A., Kraemer, T., Maurer, H.H. (2004) Screening, library-assisted identification and validated quantification of 23 benzodiazepines, flumazenil, zaleplone, zolpidem and zopiclone in plasma by liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization. Journal of Mass Spectrometry, 39, 856-872.
    • (2004) Journal of Mass Spectrometry , vol.39 , pp. 856-872
    • Kratzsch, C.1    Tenberken, O.2    Peters, F.T.3    Weber, A.A.4    Kraemer, T.5    Maurer, H.H.6
  • 7
    • 8444241854 scopus 로고    scopus 로고
    • Screening for library-assisted identification and fully validated quantification of 22 beta-blockers in blood plasma by liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization
    • Maurer, H.H., Tenberken, O., Kratzsch, C., Weber, A.A., Peters, F.T. (2004) Screening for library-assisted identification and fully validated quantification of 22 beta-blockers in blood plasma by liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization. Journal of Chromatography A, 1058, 169-181.
    • (2004) Journal of Chromatography A , vol.1058 , pp. 169-181
    • Maurer, H.H.1    Tenberken, O.2    Kratzsch, C.3    Weber, A.A.4    Peters, F.T.5
  • 8
    • 23944521531 scopus 로고    scopus 로고
    • Opiate concentrations in hair from subjects in a controlled heroin-maintenance program and from opiate-associated fatalities
    • Musshoff, F., Lachenmeier, K., Wollersen, H., Lichtermann, D., Madea, B. Opiate concentrations in hair from subjects in a controlled heroin-maintenance program and from opiate-associated fatalities. Journal of Analytical Toxicology, 29, 345-352 (2005).
    • (2005) Journal of Analytical Toxicology , vol.29 , pp. 345-352
    • Musshoff, F.1    Lachenmeier, K.2    Wollersen, H.3    Lichtermann, D.4    Madea, B.5
  • 9
    • 0038300714 scopus 로고    scopus 로고
    • Therapeutic and toxic blood concentrations of more than 800 drugs and other xenobiotics
    • Schulz, M., Schmoldt, A. (2003) Therapeutic and toxic blood concentrations of more than 800 drugs and other xenobiotics. Pharmazie, 58, 447-474.
    • (2003) Pharmazie , vol.58 , pp. 447-474
    • Schulz, M.1    Schmoldt, A.2
  • 10
    • 84871066998 scopus 로고    scopus 로고
    • Therapeutic and Toxic Drug Concentrations List, (May)
    • Therapeutic and Toxic Drug Concentrations List, www.tiaft.org/tmembers/ttv/ttv_all.html (May 2005).
    • (2005)
  • 12
    • 0346158187 scopus 로고    scopus 로고
    • A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts
    • Mallet, C.R., Lu, Z., Mazzeo, J.R. (2004) A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts. Rapid Communications in Mass Spectrometry, 18, 49-58.
    • (2004) Rapid Communications in Mass Spectrometry , vol.18 , pp. 49-58
    • Mallet, C.R.1    Lu, Z.2    Mazzeo, J.R.3
  • 13
    • 0037663202 scopus 로고    scopus 로고
    • Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    • Matuszewski, B., Constanzer, M., Chavez-Eng, C. (2003) Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. Analytical Chemistry, 75, 3019-3030.
    • (2003) Analytical Chemistry , vol.75 , pp. 3019-3030
    • Matuszewski, B.1    Constanzer, M.2    Chavez-Eng, C.3
  • 14
    • 70449701837 scopus 로고    scopus 로고
    • Simultaneous screening and quantification of 29 drugs of abuse in oral fluid by solid-phase extraction and ultraperformance LC-MS-MS
    • Badawi, N., Simonsen, K.W., Steentoft, A., Bernhoft, I.M., Linnet, K. (2009) Simultaneous screening and quantification of 29 drugs of abuse in oral fluid by solid-phase extraction and ultraperformance LC-MS-MS. Clinical Chemistry, 55, 2004-2018.
    • (2009) Clinical Chemistry , vol.55 , pp. 2004-2018
    • Badawi, N.1    Simonsen, K.W.2    Steentoft, A.3    Bernhoft, I.M.4    Linnet, K.5
  • 15
    • 78649392445 scopus 로고    scopus 로고
    • Ion suppression and enhancement effects of co-eluting analytes in multi-analyte approaches: Systematic investigation using ultra-highperformance liquid chromatography-mass spectrometry with atmospheric-pressure chemical ionization or electrospray ionization
    • Remane, D., Meyer, M.R., Wissenbach, D.K., Maurer, H.H. (2010) Ion suppression and enhancement effects of co-eluting analytes in multi-analyte approaches: Systematic investigation using ultra-highperformance liquid chromatography-mass spectrometry with atmospheric-pressure chemical ionization or electrospray ionization. Rapid Communications in Mass Spectrometry, 24, 3103-3108.
    • (2010) Rapid Communications in Mass Spectrometry , vol.24 , pp. 3103-3108
    • Remane, D.1    Meyer, M.R.2    Wissenbach, D.K.3    Maurer, H.H.4
  • 16
    • 77955983055 scopus 로고    scopus 로고
    • Fast and simple procedure for liquid-liquid extraction of 136 analytes from different drug classes for development of a liquid chromatographic-tandem mass spectrometric quantification method in human blood plasma
    • Remane, D., Meyer, M.R., Peters, F.T., Wissenbach, D.K., Maurer, H.H. (2010) Fast and simple procedure for liquid-liquid extraction of 136 analytes from different drug classes for development of a liquid chromatographic-tandem mass spectrometric quantification method in human blood plasma. Analytical and Bioanalytical Chemistry, 397, 2303-2314.
    • (2010) Analytical and Bioanalytical Chemistry , vol.397 , pp. 2303-2314
    • Remane, D.1    Meyer, M.R.2    Peters, F.T.3    Wissenbach, D.K.4    Maurer, H.H.5
  • 17
    • 79956272805 scopus 로고    scopus 로고
    • Full validation and application of an ultra-high performance liquid chromatographic-tandem mass spectrometric procedure for target screening and quantification of 34 antidepressants in human blood plasma as part of a comprehensive multi-analyte approach
    • Remane, D., Meyer, M.R., Wissenbach, D.K., Maurer, H.H. (2011) Full validation and application of an ultra-high performance liquid chromatographic-tandem mass spectrometric procedure for target screening and quantification of 34 antidepressants in human blood plasma as part of a comprehensive multi-analyte approach. Analytical and Bioanalytical Chemistry, 400, 2093-2107.
    • (2011) Analytical and Bioanalytical Chemistry , vol.400 , pp. 2093-2107
    • Remane, D.1    Meyer, M.R.2    Wissenbach, D.K.3    Maurer, H.H.4
  • 18
    • 78049504396 scopus 로고    scopus 로고
    • A validated method for simultaneous screening and quantification of twenty-three benzodiazepines and metabolites plus zopiclone and zaleplone in whole blood by liquid-liquid extraction ultraperformance liquid chromatography-tandem mass spectrometry
    • Simonsen, K.W., Hermansson, S., Steentoft, A., Linnet, K. (2010) A validated method for simultaneous screening and quantification of twenty-three benzodiazepines and metabolites plus zopiclone and zaleplone in whole blood by liquid-liquid extraction ultraperformance liquid chromatography-tandem mass spectrometry. Journal of Analytical Toxicology, 34, 332-341.
    • (2010) Journal of Analytical Toxicology , vol.34 , pp. 332-341
    • Simonsen, K.W.1    Hermansson, S.2    Steentoft, A.3    Linnet, K.4
  • 20
    • 67650376579 scopus 로고    scopus 로고
    • Key aspects of analytical method validation and linearity evaluation
    • Araujo, P. (2009) Key aspects of analytical method validation and linearity evaluation. Journal of Chromatography B, 877, 2224-2234.
    • (2009) Journal of Chromatography B , vol.877 , pp. 2224-2234
    • Araujo, P.1
  • 22
    • 66349108671 scopus 로고    scopus 로고
    • Metodevalidering i kemiske analytiske laboratorier. Kvantitative analysemetoder
    • (September)
    • Metodevalidering i kemiske analytiske laboratorier. Kvantitative analysemetoder. http://www2.danak.dk/akkreditering/RL/RL1.pdf (September 2008).
    • (2008)
  • 23
    • 84861234752 scopus 로고    scopus 로고
    • Toxicological screening of basic drugs in whole blood using UPLC-TOF-MS
    • September 13, 10.1002/dta.303
    • Dalsgaard, P.W., Rasmussen, B.S., Müller, I.B., Linnet, K. Toxicological screening of basic drugs in whole blood using UPLC-TOF-MS. Drug Testing and Analysis, September 13, 2011: 10.1002/dta.303.
    • (2011) Drug Testing and Analysis
    • Dalsgaard, P.W.1    Rasmussen, B.S.2    Müller, I.B.3    Linnet, K.4
  • 24
    • 49949152638 scopus 로고    scopus 로고
    • Dominance of pre-analytical over analytical variation for measurement of methadone and its main metabolite in postmortem femoral blood
    • Linnet, K., Johansen, S.S., Buchard, A., Munkholm, J., Morling, N. (2008) Dominance of pre-analytical over analytical variation for measurement of methadone and its main metabolite in postmortem femoral blood. Forensic Science International, 179, 78-82.
    • (2008) Forensic Science International , vol.179 , pp. 78-82
    • Linnet, K.1    Johansen, S.S.2    Buchard, A.3    Munkholm, J.4    Morling, N.5
  • 25
    • 34447314500 scopus 로고    scopus 로고
    • Systematic comparison of bias and precision data obtained with multiple-point and one-point calibration in six validated multianalyte assays for quantification of drugs in human plasma
    • Peters, F.T., Maurer, H.H. (2007) Systematic comparison of bias and precision data obtained with multiple-point and one-point calibration in six validated multianalyte assays for quantification of drugs in human plasma. Analytical Chemistry, 79, 4967-4976.
    • (2007) Analytical Chemistry , vol.79 , pp. 4967-4976
    • Peters, F.T.1    Maurer, H.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.