메뉴 건너뛰기




Volumn 99, Issue 1, 2013, Pages e1-

Seven-day subcutaneous continuous glucose monitoring demonstrates that treatment with acarbose attenuates late dumping syndrome in a woman with gastrectomy for gastric cancer

Author keywords

[No Author keywords available]

Indexed keywords

ACARBOSE; SULFONYLUREA;

EID: 84871031879     PISSN: 01688227     EISSN: 18728227     Source Type: Journal    
DOI: 10.1016/j.diabres.2012.10.021     Document Type: Letter
Times cited : (14)

References (8)
  • 1
    • 78049377249 scopus 로고    scopus 로고
    • Large-scale investigation into dumping syndrome after gastrectomy for gastric cancer
    • Mine S., Sano T., Tsutsumi K., Murakami Y., Ehara K., Saka M., et al. Large-scale investigation into dumping syndrome after gastrectomy for gastric cancer. J Am Coll Surg 2010, 211:628-636.
    • (2010) J Am Coll Surg , vol.211 , pp. 628-636
    • Mine, S.1    Sano, T.2    Tsutsumi, K.3    Murakami, Y.4    Ehara, K.5    Saka, M.6
  • 3
    • 0141993241 scopus 로고    scopus 로고
    • Acarbose and idiopathic reactive hypoglycemia
    • Peter S. Acarbose and idiopathic reactive hypoglycemia. Horm Res 2003, 60:166-167.
    • (2003) Horm Res , vol.60 , pp. 166-167
    • Peter, S.1
  • 5
    • 33845983671 scopus 로고    scopus 로고
    • Postprandial reactive hypoglycemia in an oldest-old patient effectively treated with low-dose acarbose
    • Tamura Y., Araki A., Chiba Y., Horiuchi T., Mori S., Hosoi T. Postprandial reactive hypoglycemia in an oldest-old patient effectively treated with low-dose acarbose. Endocr J 2006, 53:767-771.
    • (2006) Endocr J , vol.53 , pp. 767-771
    • Tamura, Y.1    Araki, A.2    Chiba, Y.3    Horiuchi, T.4    Mori, S.5    Hosoi, T.6
  • 6
    • 0033188401 scopus 로고    scopus 로고
    • Continuous glucose monitoring: long-term implantable sensor approach
    • Daniloff G.Y. Continuous glucose monitoring: long-term implantable sensor approach. Diabetes Technol Ther 1999, 1:261-266.
    • (1999) Diabetes Technol Ther , vol.1 , pp. 261-266
    • Daniloff, G.Y.1
  • 7
    • 77954771882 scopus 로고    scopus 로고
    • Glycemic variability using continuous glucose monitoring and endothelial function in the metabolic syndrome and in type 2 diabetes
    • Buscemi S., Re A., Batsis J.A., Arnone M., Mattina A., Cerasola G., et al. Glycemic variability using continuous glucose monitoring and endothelial function in the metabolic syndrome and in type 2 diabetes. Diabet Med 2010, 27:872-878.
    • (2010) Diabet Med , vol.27 , pp. 872-878
    • Buscemi, S.1    Re, A.2    Batsis, J.A.3    Arnone, M.4    Mattina, A.5    Cerasola, G.6
  • 8
    • 73949155093 scopus 로고    scopus 로고
    • Usefulness of continuous glucose monitoring for the diagnosis of hypoglycemia after a gastric bypass in a patient previously treated for type 2 diabetes
    • Hanaire H., Dubet A., Chauveau M.E., Anduze Y., Fernandes M., Melki V., et al. Usefulness of continuous glucose monitoring for the diagnosis of hypoglycemia after a gastric bypass in a patient previously treated for type 2 diabetes. Obes Surg 2010, 20:126-129.
    • (2010) Obes Surg , vol.20 , pp. 126-129
    • Hanaire, H.1    Dubet, A.2    Chauveau, M.E.3    Anduze, Y.4    Fernandes, M.5    Melki, V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.