메뉴 건너뛰기




Volumn 59, Issue 12, 2012, Pages 2676-2683

Ultrasound contrast plane wave imaging

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC PRESSURES; CLINICAL SCANNERS; CONTINUOUS MONITORING; CONTRAST IMAGING; CONVENTIONAL IMAGING; MICRO-BUBBLE; MICROBUBBLES; NEGATIVE PRESSURES; NONLINEAR IMAGING; PEAK PRESSURE; PERFUSION IMAGING; PLANE WAVE; PLANE-WAVE TRANSMISSION; SIMILAR IMAGE; ULTRA-FAST; ULTRASOUND CONTRAST; VASCULATURE; VESSEL PHANTOM;

EID: 84870992829     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2012.2508     Document Type: Article
Times cited : (158)

References (28)
  • 1
    • 33749432275 scopus 로고    scopus 로고
    • Microbubble contrast for radiological imaging: 1. Principles
    • PII 0001364420060300000003
    • P. Burns and S. Wilson, "Microbubble contrast for radiological imaging: 1. Principles, " Ultrasound Q., vol. 22, no. 1, pp. 5-13, 2006. (Pubitemid 44510222)
    • (2006) Ultrasound Quarterly , vol.22 , Issue.1 , pp. 5-13
    • Burns, P.N.1    Wilson, S.R.2
  • 2
    • 0034154869 scopus 로고    scopus 로고
    • Detection procedures of ultrasound contrast agents
    • DOI 10.1016/S0041-624X(99)00071-2
    • N. De Jong, P. Frinking, A. Bouakaz, and F. Ten Cate "Detection procedures of ultrasound contrast agents, " Ultrasonics, vol. 38, no. 1-8, pp. 87-92, 2000. (Pubitemid 30592603)
    • (2000) Ultrasonics , vol.38 , Issue.1 , pp. 87-92
    • De Jong, N.1    Frinking, P.J.A.2    Bouakaz, A.3    Ten Cate, F.J.4
  • 3
    • 0033096935 scopus 로고    scopus 로고
    • Pulse inversion doppler: A new method for detecting nonlinear echoes from microbubble contrast agents
    • D. H. Simpson, C. T. Chin, and P. N. Burns, "Pulse inversion doppler: a new method for detecting nonlinear echoes from microbubble contrast agents, " IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 46, no. 2, pp. 372-382, 1998.
    • (1998) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.46 , Issue.2 , pp. 372-382
    • Simpson, D.H.1    Chin, C.T.2    Burns, P.N.3
  • 4
    • 13644249895 scopus 로고    scopus 로고
    • Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power
    • DOI 10.1016/j.ultrasmedbio.2004.10.004, PII S030156290400300X
    • R. Eckersley, C. Chin, and P. Burns, "Optimising phase and ampli-tude modulation schemes for imaging microbubble contrast agents at low acoustic power, " Ultrasound Med. Biol., vol. 31, no. 2, pp. 213-219, 2005. (Pubitemid 40228777)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.2 , pp. 213-219
    • Eckersley, R.J.1    Chin, C.T.2    Burns, P.N.3
  • 5
    • 83155190232 scopus 로고    scopus 로고
    • Contrast echocardiography: Applications and limitations
    • K. Wei, "Contrast echocardiography: applications and limitations, " Cardiol. Rev., vol. 20, no. 1, pp. 25-32, 2012.
    • (2012) Cardiol. Rev. , vol.20 , Issue.1 , pp. 25-32
    • Wei, K.1
  • 6
    • 33749432923 scopus 로고    scopus 로고
    • Microbubble contrast for radiological imaging: 2. Applications
    • PII 0001364420060300000004
    • S. R. Wilson and P. N. Burns, "Microbubble contrast for radiological imaging: 2. applications, " Ultrasound Q., vol. 22, no. 1, pp. 15-18, 2006. (Pubitemid 44510223)
    • (2006) Ultrasound Quarterly , vol.22 , Issue.1 , pp. 15-18
    • Wilson, S.R.1    Burns, P.N.2
  • 7
    • 69849095682 scopus 로고    scopus 로고
    • Molecular imaging of cardiovascular disease with contrast-enhanced ultrasonography
    • J. R. Lindner, "Molecular imaging of cardiovascular disease with contrast-enhanced ultrasonography, " Nature Rev. Cardiol., vol. 6, no. 7, pp. 475-481, 2009.
    • (2009) Nature Rev. Cardiol. , vol.6 , Issue.7 , pp. 475-481
    • Lindner, J.R.1
  • 9
    • 0034821926 scopus 로고    scopus 로고
    • Assessment of infammation with contrast ultra-sound
    • J. R. Lindner "Assessment of infammation with contrast ultra-sound, " Prog. Cardiovasc. Dis., vol. 44, no. 2, pp. 111-120, 2001.
    • (2001) Prog. Cardiovasc. Dis. , vol.44 , Issue.2 , pp. 111-120
    • Lindner, J.R.1
  • 10
    • 79959834747 scopus 로고    scopus 로고
    • Improved fow measurement using micro-bubble contrast agents and disruption-replenishment: Clinical application to tumour monitoring
    • J. Hudson, R. Williams, B. Lloyd, M. Atri, T. K. Kim, G. Bjarna-son, and P. N. Burns, "Improved fow measurement using micro-bubble contrast agents and disruption-replenishment: clinical application to tumour monitoring, " Ultrasound Med. Biol., vol. 37, no. 8, pp. 1210-1221, 2011.
    • (2011) Ultrasound Med. Biol. , vol.37 , Issue.8 , pp. 1210-1221
    • Hudson, J.1    Williams, R.2    Lloyd, B.3    Atri, M.4    Kim, T.K.5    Bjarna-Son, G.6    Burns, P.N.7
  • 12
    • 47549099626 scopus 로고    scopus 로고
    • Effects of Acoustic Insonation Parameters on Ultrasound Contrast Agent Destruction
    • DOI 10.1016/j.ultrasmedbio.2007.12.020, PII S0301562908000069
    • C. Yeh and S. Su, "Effects of acoustic insonation parameters on ultrasound contrast agent destruction, " Ultrasound Med. Biol., vol. 34, no. 8, pp. 1281-1291, 2008. (Pubitemid 352010457)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.8 , pp. 1281-1291
    • Yeh, C.-K.1    Su, S.-Y.2
  • 14
    • 0036771559 scopus 로고    scopus 로고
    • Ultrafast compound imaging for 2-D motion vector estimation: Application to transient elastography
    • DOI 10.1109/TUFFC.2002.1041078
    • M. Tanter, J. Bercof, L. Sandrin, and M. Fink, "Ultrafast com-pound imaging for 2-d motion vector estimation: application to transient elastography, " IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 49, no. 10, pp. 1363-1374, 2002. (Pubitemid 35250638)
    • (2002) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , vol.49 , Issue.10 , pp. 1363-1374
    • Tanter, M.1    Bercoff, J.2    Sandrin, L.3    Fink, M.4
  • 15
    • 2442466831 scopus 로고    scopus 로고
    • Supersonic shear imaging: A new technique for soft tissue elasticity mapping
    • J. Bercof, M. Tanter, and M. Fink, "Supersonic shear imaging: a new technique for soft tissue elasticity mapping, " IEEE Trans. Ul-trason. Ferroelectr. Freq. Control, vol. 51, no. 4, pp. 396-409, 2004.
    • (2004) IEEE Trans. Ul-trason. Ferroelectr. Freq. Control , vol.51 , Issue.4 , pp. 396-409
    • Bercof, J.1    Tanter, M.2    Fink, M.3
  • 16
    • 65349145884 scopus 로고    scopus 로고
    • Co-herent plane-wave compounding for very high frame rate ultraso-nography and transient elastography
    • G. Montaldo, M. Tanter, J. Bercof, N. Benech, and M. Fink, "Co-herent plane-wave compounding for very high frame rate ultraso-nography and transient elastography, " IEEE Trans. Ultrason. Fer-roelectr. Freq. Control, vol. 56, no. 3, pp. 489-506, 2009.
    • (2009) IEEE Trans. Ultrason. Fer-roelectr. Freq. Control , vol.56 , Issue.3 , pp. 489-506
    • Montaldo, G.1    Tanter, M.2    Bercof, J.3    Benech, N.4    Fink, M.5
  • 22
    • 76349125319 scopus 로고    scopus 로고
    • Ul-trasound characterization of red blood cell aggregation with inter-vening attenuating tissue-mimicking phantoms
    • E. Franceschini, F. T. H. yu, F. Destrempes, and G. Cloutier, "Ul-trasound characterization of red blood cell aggregation with inter-vening attenuating tissue-mimicking phantoms, " J. Acoust. Soc. Am., vol. 127, no. 2, pp. 1104-1115, 2010.
    • (2010) J. Acoust. Soc. Am. , vol.127 , Issue.2 , pp. 1104-1115
    • Franceschini, E.1    Yu, F.T.H.2    Destrempes, F.3    Cloutier, G.4
  • 23
    • 35448972169 scopus 로고    scopus 로고
    • Quantitative Measurement of Ultrasound Disruption of Polymer-Shelled Microbubbles
    • DOI 10.1016/j.ultrasmedbio.2007.05.013, PII S030156290700261X
    • P. D. Bevan, R. Karshafan, E. G. Tickner, and P. N. Burns, "Quan-titative measurement of ultrasound disruption of polymer-shelled microbubbles, " Ultrasound Med. Biol., vol. 33, no. 11, pp. 1777-1786, 2007. (Pubitemid 47633005)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.11 , pp. 1777-1786
    • Bevan, P.D.1    Karshafian, R.2    Tickner, E.G.3    Burns, P.N.4
  • 24
    • 14144253562 scopus 로고    scopus 로고
    • Contrast-agent detection and quantif-cation
    • P. Phillips And E. Gardner, "Contrast-agent detection and quantif-cation, " Eur. Radiol. Suppl., vol. 9, pp. 4-10, 2004.
    • (2004) Eur. Radiol. Suppl. , vol.9 , pp. 4-10
    • Phillips, P.1    Gardner, E.2
  • 25
    • 51849168524 scopus 로고    scopus 로고
    • Suppression of tissue harmonics for pulse-inversion contrast im-aging using time reversal
    • O. Couture, J. F. Aubry, G. Montaldo, M. Tanter, and M. Fink, "Suppression of tissue harmonics for pulse-inversion contrast im-aging using time reversal, " Phys. Med. Biol., vol. 53, no. 19, pp. 5469-5480, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , Issue.19 , pp. 5469-5480
    • Couture, O.1    Aubry, J.F.2    Montaldo, G.3    Tanter, M.4    Fink, M.5
  • 26


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.