메뉴 건너뛰기




Volumn 39, Issue 12, 2012, Pages 7185-7193

Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT

Author keywords

distortion; MR linac; MRgRT; MRI; MRIgRT; simulation; tissue magnetic susceptibility

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DATA HANDLING; DISTORTION (WAVES); ENCODING (SYMBOLS); GEOMETRY; HOSPITAL DATA PROCESSING; LINEAR ACCELERATORS; MAGNETIC FIELDS; MAGNETIC RESONANCE IMAGING; MAGNETIC SUSCEPTIBILITY; MAGNETS; NUMERICAL MODELS; PHANTOMS; PHASE INTERFACES; SIGNAL ENCODING;

EID: 84870920554     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4764481     Document Type: Article
Times cited : (82)

References (18)
  • 1
    • 66449118760 scopus 로고    scopus 로고
    • First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system
    • 10.1118/1.3125662
    • B. Fallone, B. Murray, S. Rathee, T. Stanescu, S. Steciw, S. Vidakovic, E. Blosser, and D. Tymofichuk, First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system., Med. Phys. 36 (6), 2084-2088 (2009). 10.1118/1.3125662
    • (2009) Med. Phys. , vol.36 , Issue.6 , pp. 2084-2088
    • Fallone, B.1    Murray, B.2    Rathee, S.3    Stanescu, T.4    Steciw, S.5    Vidakovic, S.6    Blosser, E.7    Tymofichuk, D.8
  • 3
    • 76149083389 scopus 로고    scopus 로고
    • A real-time MRI guided external beam radiotherapy system
    • 10.1118/1.2241803
    • J. Dempsey, A real-time MRI guided external beam radiotherapy system., Med. Phys. 33 (6), 2254 (2006). 10.1118/1.2241803
    • (2006) Med. Phys. , vol.33 , Issue.6 , pp. 2254
    • Dempsey, J.1
  • 4
    • 79959578754 scopus 로고    scopus 로고
    • Image-guided radiation therapy: Emergence of MR-guided radiation treatment (MRgRT) systems
    • 10.1117/12.848608
    • D. Jaffray, M. Carlone, C. Menard, and S. Breen, Image-guided radiation therapy: emergence of MR-guided radiation treatment (MRgRT) systems., Proc. SPIE 7622, 762202 (2010). 10.1117/12.848608
    • (2010) Proc. SPIE , vol.7622 , pp. 762202
    • Jaffray, D.1    Carlone, M.2    Menard, C.3    Breen, S.4
  • 5
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • 10.1118/1.597854
    • J. F. Schenck, The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds., Med. Phys. 23 (6), 815-850 (1996). 10.1118/1.597854
    • (1996) Med. Phys. , vol.23 , Issue.6 , pp. 815-850
    • Schenck, J.F.1
  • 6
    • 0022352939 scopus 로고
    • Susceptibility artefacts in NMR imaging
    • 10.1016/0730-725X(85)90397-2
    • K. Ludeke, P. Roschmann, and R. Tischler, Susceptibility artefacts in NMR imaging., Magn. Reson. Imaging 3, 329-343 (1985). 10.1016/0730-725X(85)90397-2
    • (1985) Magn. Reson. Imaging , vol.3 , pp. 329-343
    • Ludeke, K.1    Roschmann, P.2    Tischler, R.3
  • 7
    • 0025361232 scopus 로고
    • Bulk magnetic susceptibility shifts in nmr studies of compartmentalized samples: Use of paramagnetic reagents
    • 10.1002/mrm.1910130207
    • S. Chu, Y. Xu, J. Balschi, and C. Springer, Bulk magnetic susceptibility shifts in nmr studies of compartmentalized samples: Use of paramagnetic reagents., Magn. Reson. Med. 13, 239-262 (1990). 10.1002/mrm.1910130207
    • (1990) Magn. Reson. Med. , vol.13 , pp. 239-262
    • Chu, S.1    Xu, Y.2    Balschi, J.3    Springer, C.4
  • 8
    • 0025517450 scopus 로고
    • Effect of field strength on susceptibility artifacts in magnetic resonance imaging
    • 10.1016/0895-6111(90)90040-I
    • K. Farahani, U. Sinha, S. Sinha, L. C. Chiu, and R. B. Lufkin, Effect of field strength on susceptibility artifacts in magnetic resonance imaging., Comput. Med. Imaging Graph. 14 (6), 409-413 (1990). 10.1016/0895-6111(90)90040-I
    • (1990) Comput. Med. Imaging Graph. , vol.14 , Issue.6 , pp. 409-413
    • Farahani, K.1    Sinha, U.2    Sinha, S.3    Chiu, L.C.4    Lufkin, R.B.5
  • 10
    • 0028079558 scopus 로고
    • Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D
    • 10.1016/0730-725X(94)92357-4
    • R. Bhagwandien, M. Moerland, C. Bakker, R. Beersma, and J. Lagendijk, Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D., Magn. Reson. Imaging 12, 101-107 (1994). 10.1016/0730-725X(94)92357-4
    • (1994) Magn. Reson. Imaging , vol.12 , pp. 101-107
    • Bhagwandien, R.1    Moerland, M.2    Bakker, C.3    Beersma, R.4    Lagendijk, J.5
  • 11
    • 0026925939 scopus 로고
    • A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
    • 10.1109/42.158935
    • H. Chang and J. Fitzpatrick, A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities., IEEE Trans. Med. Imaging 11, 319-329 (1992). 10.1109/42.158935
    • (1992) IEEE Trans. Med. Imaging , vol.11 , pp. 319-329
    • Chang, H.1    Fitzpatrick, J.2
  • 12
    • 4243079824 scopus 로고    scopus 로고
    • Perturbation method for magnetic field calculations of nonconductive objects
    • 10.1002/mrm.20194
    • M. Jenkinson, J. L. Wilson, and P. Jezzard, Perturbation method for magnetic field calculations of nonconductive objects., Magn. Reson. Med. 52 (3), 471-477 (2004). 10.1002/mrm.20194
    • (2004) Magn. Reson. Med. , vol.52 , Issue.3 , pp. 471-477
    • Jenkinson, M.1    Wilson, J.L.2    Jezzard, P.3
  • 13
    • 77950555280 scopus 로고    scopus 로고
    • Implications of tissue magnetic susceptibility-related distortion on the rotating magnet in an MR-linac design
    • 10.1118/1.3355856
    • K. Wachowicz, T. Stanescu, S. D. Thomas, and B. G. Fallone, Implications of tissue magnetic susceptibility-related distortion on the rotating magnet in an MR-linac design., Med. Phys. 37 (4), 1714-1721 (2010). 10.1118/1.3355856
    • (2010) Med. Phys. , vol.37 , Issue.4 , pp. 1714-1721
    • Wachowicz, K.1    Stanescu, T.2    Thomas, S.D.3    Fallone, B.G.4
  • 14
    • 77954285495 scopus 로고    scopus 로고
    • Investigation of a 3D system distortion correction method for MR images
    • T. Stanescu, H. S. Jans, K. Wachowicz, and B. G. Fallone, Investigation of a 3D system distortion correction method for MR images., J. Appl. Clin. Med. Phys. 11 (1), 200-216 (2010).
    • (2010) J. Appl. Clin. Med. Phys. , vol.11 , Issue.1 , pp. 200-216
    • Stanescu, T.1    Jans, H.S.2    Wachowicz, K.3    Fallone, B.G.4
  • 15
    • 47649103932 scopus 로고    scopus 로고
    • A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions
    • 10.1088/0031-9155/53/13/013
    • T. Stanescu, H. S. Jans, N. Pervez, P. Stavrev, and B. G. Fallone, A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions., Phys. Med. Biol. 53 (13), 3579-3593 (2008). 10.1088/0031-9155/53/13/013
    • (2008) Phys. Med. Biol. , vol.53 , Issue.13 , pp. 3579-3593
    • Stanescu, T.1    Jans, H.S.2    Pervez, N.3    Stavrev, P.4    Fallone, B.G.5
  • 16
    • 33845312681 scopus 로고    scopus 로고
    • Characterization of the susceptibility artifact around a prostate brachytherapy seed in MRI
    • 10.1118/1.2364052
    • K. Wachowicz, S. D. Thomas, and B. G. Fallone, Characterization of the susceptibility artifact around a prostate brachytherapy seed in MRI., Med. Phys. 33 (12), 4459-4467 (2006). 10.1118/1.2364052
    • (2006) Med. Phys. , vol.33 , Issue.12 , pp. 4459-4467
    • Wachowicz, K.1    Thomas, S.D.2    Fallone, B.G.3
  • 17
    • 0026688913 scopus 로고
    • Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging
    • 10.1016/0730-725X(92)90011-N
    • C. J. Bakker, M. A. Moerland, R. Bhagwandien, and R. Beersma, Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging., Magn. Reson. Imaging 10 (4), 597-608 (1992). 10.1016/0730-725X(92)90011-N
    • (1992) Magn. Reson. Imaging , vol.10 , Issue.4 , pp. 597-608
    • Bakker, C.J.1    Moerland, M.A.2    Bhagwandien, R.3    Beersma, R.4
  • 18
    • 79551677546 scopus 로고    scopus 로고
    • Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapy
    • 10.1088/0031-9155/56/1/017
    • S. P. Crijns, B. W. Raaymakers, and J. J. Lagendijk, Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapy., Phys. Med. Biol. 56 (1), 289-297 (2011). 10.1088/0031-9155/56/1/017
    • (2011) Phys. Med. Biol. , vol.56 , Issue.1 , pp. 289-297
    • Crijns, S.P.1    Raaymakers, B.W.2    Lagendijk, J.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.