메뉴 건너뛰기




Volumn 404, Issue 8, 2012, Pages 2267-2275

Bead affinity chromatography in a temperature-controllable microsystem for biomarker detection

Author keywords

Aptamer immobilized bead affinity chromatography; Carcinoembryonic antigen (CEA); MALDI TOF MS; Temperature controllable microfluidics

Indexed keywords

CANCER BIOMARKER DETECTIONS; CANCER MARKERS; CANCER RESEARCH; CARCINOEMBRYONIC ANTIGEN; HUMAN SERUM; MALDI TOF MS; MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME OF FLIGHTS; MICRO-REACTOR; MICROBEADS; PROTEIN ANALYSIS; REACTION CHAMBERS; SAMPLE PREPARATION; SINGLE CRYSTALLINE SILICON; TEMPERATURE CONTROL UNIT;

EID: 84870906236     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-012-6380-1     Document Type: Article
Times cited : (19)

References (27)
  • 2
    • 0037253089 scopus 로고    scopus 로고
    • Protein arrays: The current state-of-the-art
    • Cutler P (2003) Protein arrays: the current state-of-the-art. Proteomics 3:3-18
    • (2003) Proteomic , vol.3 , pp. 3-18
    • Cutler, P.1
  • 3
    • 0035866668 scopus 로고    scopus 로고
    • Determination of carcinoembryonic antigen in human sera by integrated bead bed immunoasay in a microchip for cancer diagnosis
    • Sato K, Tokeshi M, Kimura H, Kitamori T (2001) Determination of carcinoembryonic antigen in human sera by integrated bead bed immunoasay in a microchip for cancer diagnosis. Anal Chem 73:1213-1218
    • (2001) Anal Chem , vol.73 , pp. 1213-1218
    • Sato, K.1    Tokeshi, M.2    Kimura, H.3    Kitamori, T.4
  • 4
    • 38749146242 scopus 로고    scopus 로고
    • Channel-resolved multianalyte immunosensing system for flow-through chemiluminescent detection of alpha-fetoprotein and carcinoembryonic antigen
    • Fu ZF, Yan F, Liu H, Yang ZJ, Ju HX (2008) Channel-resolved multianalyte immunosensing system for flow-through chemiluminescent detection of alpha-fetoprotein and carcinoembryonic antigen. Biosens Bioelectron 23:1063-1069
    • (2008) Biosens Bioelectron , vol.23 , pp. 1063-1069
    • Fu, Z.F.1    Yan, F.2    Liu, H.3    Yang, Z.J.4    Ju, H.X.5
  • 5
    • 20344407785 scopus 로고    scopus 로고
    • Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode
    • Dai Z, Chen J, Yan F, Ju HX (2005) Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode. Cancer Detect Prev 29:233- 240
    • (2005) Cancer Detect Prev , vol.29 , pp. 233-240
    • Dai, Z.1    Chen, J.2    Yan, F.3    Ju, H.X.4
  • 6
    • 0038306617 scopus 로고    scopus 로고
    • On-chip protein sample desalting and preparation for direct coupling with electrospray ionization mass spectrometry
    • Lion N, Gellon JO, Jensen H, Girault HH (2003) On-chip protein sample desalting and preparation for direct coupling with electrospray ionization mass spectrometry. J Chromatogr A 1003:11-19
    • (2003) J Chromatogr A , vol.1003 , pp. 11-19
    • Lion, N.1    Gellon, J.O.2    Jensen, H.3    Girault, H.H.4
  • 7
    • 12244270639 scopus 로고    scopus 로고
    • Digital microfluidics with in-line sample purification for proteomics analyses with MALDI-MS
    • Wheeler AR, Moon H, Bird CA, Loo RRO, Kim CJ, Loo JA, Garrell RL (2005) Digital microfluidics with in-line sample purification for proteomics analyses with MALDI-MS. Anal Chem 77:534-540
    • (2005) Anal Chem , vol.77 , pp. 534-540
    • Wheeler, A.R.1    Moon, H.2    Bird, C.A.3    Loo, R.R.O.4    Kim, C.J.5    Loo, J.A.6    Garrell, R.L.7
  • 9
    • 0344494027 scopus 로고    scopus 로고
    • Applications of affinity chromatography in proteomics
    • Lee WC, Lee KH (2004) Applications of affinity chromatography in proteomics. Anal Biochem 324:1-10
    • (2004) Anal Biochem , vol.324 , pp. 1-10
    • Lee, W.C.1    Lee, K.H.2
  • 10
    • 0035975871 scopus 로고    scopus 로고
    • Efficient elution of functional proteins in affinity chromatography
    • Firer MA (2001) Efficient elution of functional proteins in affinity chromatography. J Biochem Biophys Methods 49:433- 442
    • (2001) J Biochem Biophys Methods , vol.49 , pp. 433-442
    • Firer, M.A.1
  • 11
    • 14944375203 scopus 로고    scopus 로고
    • Microaffinity purification of proteins based on photolytic elution: Toward an efficient microbead affinity chromatography on a chip
    • Chung WJ, Kim MS, Cho S, Park SS, Kim JH, Kim YK, Kim BG, Lee YS (2005) Microaffinity purification of proteins based on photolytic elution: toward an efficient microbead affinity chromatography on a chip. Electrophoresis 26:694-702
    • (2005) Electrophoresis , vol.26 , pp. 694-702
    • Chung, W.J.1    Kim, M.S.2    Cho, S.3    Park, S.S.4    Kim, J.H.5    Kim, Y.K.6    Kim, B.G.7    Lee, Y.S.8
  • 12
    • 10944267299 scopus 로고    scopus 로고
    • Microbead-based affinity chromatography chip using RNA aptamer modified with photocleavable linker
    • Cho S, Lee SH, Chung WJ, Kim YK, Lee YS, Kim BG (2004) Microbead-based affinity chromatography chip using RNA aptamer modified with photocleavable linker. Electrophoresis 25:3730-3739
    • (2004) Electrophoresis , vol.25 , pp. 3730-3739
    • Cho, S.1    Lee, S.H.2    Chung, W.J.3    Kim, Y.K.4    Lee, Y.S.5    Kim, B.G.6
  • 13
    • 0034212611 scopus 로고    scopus 로고
    • Thermal denaturation: A useful technique in peptide mass mapping
    • Park ZY, Russell DH (2000) Thermal denaturation: a useful technique in peptide mass mapping. Anal Chem 72:2667-2670
    • (2000) Anal Chem , vol.72 , pp. 2667-2670
    • Park, Z.Y.1    Russell, D.H.2
  • 14
    • 0035356917 scopus 로고    scopus 로고
    • Identification of individual proteins in complex protein mixtures by high-resolution, high-mass-accuracy MALDI TOF-mass spectrometry analysis of in-solution thermal denaturation/enzymatic digestion
    • Park ZY, Russell DH (2001) Identification of individual proteins in complex protein mixtures by high-resolution, high-mass-accuracy MALDI TOF-mass spectrometry analysis of in-solution thermal denaturation/enzymatic digestion. Anal Chem 73:2558-2564
    • (2001) Anal Chem , vol.73 , pp. 2558-2564
    • Park, Z.Y.1    Russell, D.H.2
  • 15
    • 62649100432 scopus 로고    scopus 로고
    • An aptamer-based microfluidic device for thermally controlled affinity extraction
    • Nguyen T, Pei R, Stojanovic M, Lin Q (2009) An aptamer-based microfluidic device for thermally controlled affinity extraction. Microfluid Nanofluid 6:479-487
    • (2009) Microfluid Nanoflui , vol.6 , pp. 479-487
    • Nguyen, T.1    Pei, R.2    Stojanovic, M.3    Lin, Q.4
  • 16
    • 33747090983 scopus 로고    scopus 로고
    • Control and detection of chemical reactions in microfluidic systems
    • deMello AJ (2006) Control and detection of chemical reactions in microfluidic systems. Nature 442:394-402
    • (2006) Nature , vol.442 , pp. 394-402
    • Demello, A.J.1
  • 17
    • 33644777646 scopus 로고    scopus 로고
    • Lab-on-a-chip: Microfluidics in drug discovery
    • Dittrich PS, Manz A (2006) Lab-on-a-chip: microfluidics in drug discovery. Nature Rev Drug Discov 5:210-218
    • (2006) Nature Rev Drug Disco , vol.5 , pp. 210-218
    • Dittrich, P.S.1    Manz, A.2
  • 18
    • 69349103437 scopus 로고    scopus 로고
    • Microfluidic chip: Next-generation platform for systems biology
    • Feng XJ, Du W, Luo QM, Liu BF (2009) Microfluidic chip: next-generation platform for systems biology. Anal Chim Acta 650:83-97
    • (2009) Anal Chim Acta , vol.650 , pp. 83-97
    • Feng, X.J.1    Du, W.2    Luo, Q.M.3    Liu, B.F.4
  • 20
    • 68149103284 scopus 로고    scopus 로고
    • An automated micro-solid phase extraction device involving integrated \high-pressure microvalves for genetic sample preparation
    • Han SI, Han KH, Frazier AB, Ferrance JP, Landers JP (2009) An automated micro-solid phase extraction device involving integrated \high-pressure microvalves for genetic sample preparation. Biomed Microdevices 11:935-942
    • (2009) Biomed Microdevices , vol.11 , pp. 935-942
    • Han, S.I.1    Han, K.H.2    Frazier, A.B.3    Ferrance, J.P.4    Landers, J.P.5
  • 21
    • 33750449287 scopus 로고    scopus 로고
    • Proteome-on-a-chip: Mirage, or on the horizon?
    • Freire SLS, Wheeler AR (2006) Proteome-on-a-chip: mirage, or on the horizon? Lab on a Chip 6:1415-1423
    • (2006) Lab on A Chip , vol.6 , pp. 1415-1423
    • Freire, S.L.S.1    Wheeler, A.R.2
  • 22
    • 27144481918 scopus 로고    scopus 로고
    • Integrated microfluidic device for solid-phase extraction coupled to micellar electrokinetic chromatography separation
    • Ramsey JD, Collins GE (2005) Integrated microfluidic device for solid-phase extraction coupled to micellar electrokinetic chromatography separation. Anal Chem 77:6664-6670
    • (2005) Anal Chem , vol.77 , pp. 6664-6670
    • Ramsey, J.D.1    Collins, G.E.2
  • 23
    • 0035500025 scopus 로고    scopus 로고
    • Monolithic porous polymer for on-chip solid-phase extraction and preconcentration prepared by photoinitiated in situ polymerization within a microfluidic device
    • Yu C, Davey MH, Svec F, Frechet JMJ (2001) Monolithic porous polymer for on-chip solid-phase extraction and preconcentration prepared by photoinitiated in situ polymerization within a microfluidic device. Anal Chem 73:5088-5096
    • (2001) Anal Chem , vol.73 , pp. 5088-5096
    • Yu, C.1    Davey, M.H.2    Svec, F.3    Frechet, J.M.J.4
  • 24
    • 33746537155 scopus 로고    scopus 로고
    • Application of a temperature-controllable microreactor to simple and rapid protein identification using MALDI-TOF MS
    • Sim TS, Kim EM, Joo HS, Kim BG, Kim YK (2006) Application of a temperature-controllable microreactor to simple and rapid protein identification using MALDI-TOF MS. Lab on a Chip 6:1056-1061
    • (2006) Lab on A Chi , vol.6 , pp. 1056-1061
    • Sim, T.S.1    Kim, E.M.2    Joo, H.S.3    Kim, B.G.4    Kim, Y.K.5
  • 25
    • 0036852980 scopus 로고    scopus 로고
    • Precise temperature control and rapid thermal cycling in a micromachined DNA polymerase chain reaction chip
    • Yoon DS, Lee YS, Lee Y, Cho HJ, Sung SW, Oh KW, Cha J, Lim G (2002) Precise temperature control and rapid thermal cycling in a micromachined DNA polymerase chain reaction chip. J Micromech Microeng 12:813-823
    • (2002) J Micromech Microeng , vol.12 , pp. 813-823
    • Yoon, D.S.1    Lee, Y.S.2    Lee, Y.3    Cho, H.J.4    Sung, S.W.5    Oh, K.W.6    Cha, J.7    Lim, G.8
  • 26
    • 0034250173 scopus 로고    scopus 로고
    • Precise temperature control of microfluidic chamber for gas and liquid phase reactions
    • Lao AIK, Lee TMH, Hsing IM, Ip NY (2000) Precise temperature control of microfluidic chamber for gas and liquid phase reactions. Sensors Actuators A Phys 84:11-17
    • (2000) Sensors Actuators A Phys , vol.84 , pp. 11-17
    • Lao, A.I.K.1    Lee, T.M.H.2    Hsing, I.M.3    Ip, N.Y.4
  • 27
    • 84862744821 scopus 로고    scopus 로고
    • AnRNA aptamer that binds carcinoembryonic antigen inhibits hepatic metastasis ofcolon cancer cells in mice
    • LeeYJ,HanSR,KimNY,Lee SH, Jeong JS,Lee SW(2012)AnRNA aptamer that binds carcinoembryonic antigen inhibits hepatic metastasis ofcolon cancer cells in mice. Gastroenterology 143(1):155-165
    • (2012) Gastroenterology , vol.143 , Issue.1 , pp. 155-165
    • Lee, Y.J.1    Han, S.R.2    Kim, N.Y.3    Lee, S.H.4    Jeong, J.S.5    Lee, S.W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.