메뉴 건너뛰기




Volumn 51, Issue 5, 2012, Pages 415-422

Automatic correction of gaps in cerebrovascular segmentations extracted from 3D time-of-flight MRA datasets

Author keywords

Cerebrovascular system; Computerassisted image analysis; Correction; Magnetic resonance imaging; Segmentation gaps

Indexed keywords

ARTICLE; BRAIN ARTERY; BRAIN VEIN; COMPUTER ASSISTED DIAGNOSIS; DATA BASE; HUMAN; MAGNETIC RESONANCE ANGIOGRAPHY; METHODOLOGY; RADIOGRAPHY; STANDARD; THREE DIMENSIONAL IMAGING;

EID: 84870902095     PISSN: 00261270     EISSN: None     Source Type: Journal    
DOI: 10.3414/ME11-02-0037     Document Type: Article
Times cited : (15)

References (26)
  • 1
    • 79961167137 scopus 로고    scopus 로고
    • Quantification of recurrence volumes after endovascular treatment of cerebral aneurysm as surrogate endpoint for treatment stability
    • Ries T, Wegscheider K, Wulff A, Radelfahr K, Saring D, Forkert ND, et al. Quantification of recurrence volumes after endovascular treatment of cerebral aneurysm as surrogate endpoint for treatment stability. Neuroradiology 2011; 53 (8): 593-598.
    • (2011) Neuroradiology , vol.53 , Issue.8 , pp. 593-598
    • Ries, T.1    Wegscheider, K.2    Wulff, A.3    Radelfahr, K.4    Saring, D.5    Forkert, N.D.6
  • 3
    • 17444383793 scopus 로고    scopus 로고
    • Brain arteriovenous malformations in adults
    • Choi JH, Mohr JP. Brain arteriovenous malformations in adults. Lancet Neurol 2005; 4 (5): 299-308.
    • (2005) Lancet Neurol , vol.4 , Issue.5 , pp. 299-308
    • Choi, J.H.1    Mohr, J.P.2
  • 4
    • 0028295521 scopus 로고
    • Preliminary results of a modified surface rendering technique in the display of magnetic resonance angiography images
    • Shapiro LB, Tien RD, Golding SJ, Totterman SM. Preliminary results of a modified surface rendering technique in the display of magnetic resonance angiography images. Magnetic resonance imaging 1994; 12 (3): 461-468.
    • (1994) Magnetic Resonance Imaging , vol.12 , Issue.3 , pp. 461-468
    • Shapiro, L.B.1    Tien, R.D.2    Golding, S.J.3    Totterman, S.M.4
  • 5
    • 78649499002 scopus 로고    scopus 로고
    • Automatic analysis of the anatomy of arteriovenous malformations using 3D and 4D MRA image sequences
    • Forkert ND, Saring D, Handels H. Automatic analysis of the anatomy of arteriovenous malformations using 3D and 4D MRA image sequences. Stud Health Technol Inform 2010; 160 (Pt 2): 1268-1272.
    • (2010) Stud Health Technol Inform , vol.160 , Issue.Pt 2 , pp. 1268-1272
    • Forkert, N.D.1    Saring, D.2    Handels, H.3
  • 6
    • 0035213047 scopus 로고    scopus 로고
    • Threedimensional pulsatile flow simulation before and after endovascular coil embolization of a terminal cerebral aneurysm
    • Groden C, Laudan J, Gatchell S, Zeumer H. Threedimensional pulsatile flow simulation before and after endovascular coil embolization of a terminal cerebral aneurysm. J Cereb Blood Flow Metab 2001; 21 (12): 1464-1471.
    • (2001) J Cereb Blood Flow Metab , vol.21 , Issue.12 , pp. 1464-1471
    • Groden, C.1    Laudan, J.2    Gatchell, S.3    Zeumer, H.4
  • 8
    • 80052897178 scopus 로고    scopus 로고
    • Variability in visual assessment of cerebral aneurysms could be reduced by quantification of recurrence volumes
    • Groth M, Fiehler J, Forkert ND. Variability in visual assessment of cerebral aneurysms could be reduced by quantification of recurrence volumes. AJNR American journal of neuroradiology 2011; 32 (8): E163-164.
    • (2011) AJNR American Journal of Neuroradiology , vol.32 , Issue.8
    • Groth, M.1    Fiehler, J.2    Forkert, N.D.3
  • 9
    • 59349088607 scopus 로고    scopus 로고
    • Medical image computing for computer-supported diagnostics and therapy. Advances and perspectives
    • Handels H, Ehrhardt J. Medical image computing for computer-supported diagnostics and therapy. Advances and perspectives. Methods Inf Med 2009; 48 (1): 11-17.
    • (2009) Methods Inf Med , vol.48 , Issue.1 , pp. 11-17
    • Handels, H.1    Ehrhardt, J.2
  • 10
    • 0036961882 scopus 로고    scopus 로고
    • A review on MR vascular image processing: Skeleton versus nonskeleton approaches: Part II
    • Suri JS, Liu K, Reden L, Laxminarayan S. A review on MR vascular image processing: skeleton versus nonskeleton approaches: part II. IEEE Trans Inf Technol Biomed 2002; 6 (4): 338-350.
    • (2002) IEEE Trans Inf Technol Biomed , vol.6 , Issue.4 , pp. 338-350
    • Suri, J.S.1    Liu, K.2    Reden, L.3    Laxminarayan, S.4
  • 11
    • 70350345530 scopus 로고    scopus 로고
    • A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes
    • Lesage D, Angelini ED, Bloch I, Funka-Lea G. A review of 3D vessel lumen segmentation techniques: models, features and extraction schemes. Medical image analysis 2009; 13 (6): 819-845.
    • (2009) Medical Image Analysis , vol.13 , Issue.6 , pp. 819-845
    • Lesage, D.1    Angelini, E.D.2    Bloch, I.3    Funka-Lea, G.4
  • 12
    • 31744435697 scopus 로고    scopus 로고
    • Magnetic resonance angiography: From anatomical knowledge modeling to vessel segmentation
    • Passat N, Ronse C, Baruthio J, Armspach JP, Maillot C. Magnetic resonance angiography: from anatomical knowledge modeling to vessel segmentation. Medical image analysis 2006; 10 (2): 259-274.
    • (2006) Medical Image Analysis , vol.10 , Issue.2 , pp. 259-274
    • Passat, N.1    Ronse, C.2    Baruthio, J.3    Armspach, J.P.4    Maillot, C.5
  • 17
    • 27644525535 scopus 로고    scopus 로고
    • Point processes for unsupervised line network extraction in remote sensing
    • Lacoste C, Descombes X, Zerubia J. Point processes for unsupervised line network extraction in remote sensing. IEEE Trans Pattern Anal Mach Intell 2005; 27 (10): 1568-1579.
    • (2005) IEEE Trans Pattern Anal Mach Intell , vol.27 , Issue.10 , pp. 1568-1579
    • Lacoste, C.1    Descombes, X.2    Zerubia, J.3
  • 19
    • 0028550697 scopus 로고
    • Building skeleton models via 3-D medial surface/axis thinning algorithms
    • Lee TC, Kashyap RL, Chu CN. Building skeleton models via 3-D medial surface/axis thinning algorithms. CVGIP: Graph Models Image Process 1994; 56 (6): 462-478.
    • (1994) CVGIP: Graph Models Image Process , vol.56 , Issue.6 , pp. 462-478
    • Lee, T.C.1    Kashyap, R.L.2    Chu, C.N.3
  • 20
    • 0032081365 scopus 로고    scopus 로고
    • Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images
    • Sato Y, Nakajima S, Shiraga N, Atsumi H, Yoshida S, Koller T, et al. Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images. Medical image analysis 1998; 2 (2): 143-168.
    • (1998) Medical Image Analysis , vol.2 , Issue.2 , pp. 143-168
    • Sato, Y.1    Nakajima, S.2    Shiraga, N.3    Atsumi, H.4    Yoshida, S.5    Koller, T.6
  • 21
    • 34147120474 scopus 로고
    • A Note on Two Problems in Connexion with Graphs
    • Dijkstra EW. A Note on Two Problems in Connexion with Graphs. Numerische Mathematik 1959; 1: 269-271.
    • (1959) Numerische Mathematik , vol.1 , pp. 269-271
    • Dijkstra, E.W.1
  • 23
    • 70349568676 scopus 로고    scopus 로고
    • Integrated segmentation and non-linear registration for organ segmentation and motion field estimation in 4D CT data
    • Schmidt-Richberg A, Handels H, Ehrhardt J. Integrated segmentation and non-linear registration for organ segmentation and motion field estimation in 4D CT data. Methods Inf Med 2009; 48 (4): 344-349.
    • (2009) Methods Inf Med , vol.48 , Issue.4 , pp. 344-349
    • Schmidt-Richberg, A.1    Handels, H.2    Ehrhardt, J.3
  • 24
    • 0001473437 scopus 로고
    • On estimation of a probability density function and mode
    • Parzen E. On estimation of a probability density function and mode. Annals of Mathematical Statistics 1962; 33: 1065-1076.
    • (1962) Annals of Mathematical Statistics , vol.33 , pp. 1065-1076
    • Parzen, E.1
  • 25
    • 79957982657 scopus 로고    scopus 로고
    • Fuzzy-based Vascular Structure Enhancement in Time-of-Flight MRA Images for Improved Segmentation
    • Forkert ND, Schmidt-Richberg A, Fiehler J, Illies T, Moller D, Handels H, et al. Fuzzy-based Vascular Structure Enhancement in Time-of-Flight MRA Images for Improved Segmentation. Methods Inf Med 2011; 50 (1): 74-83.
    • (2011) Methods Inf Med , vol.50 , Issue.1 , pp. 74-83
    • Forkert, N.D.1    Schmidt-Richberg, A.2    Fiehler, J.3    Illies, T.4    Moller, D.5    Handels, H.6
  • 26
    • 84872687791 scopus 로고    scopus 로고
    • 3D Cerebrovascular Segmentation Combining Fuzzy Vessel Enhancement and Level-sets With Anisotropic Energy Weights
    • Epub ahead of print
    • Forkert ND, Schmidt-Richberg A, Fiehler J, Illies T, Möller D, Säring D, et al. 3D cerebrovascular segmentation combining fuzzy vessel enhancement and level-sets with anisotropic energy weights. Magn Reson Imaging 2012; Epub ahead of print.
    • (2012) Magn Reson Imaging
    • Forkert, N.D.1    Schmidt-Richberg, A.2    Fiehler, J.3    Illies, T.4    Möller, D.5    Säring, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.