메뉴 건너뛰기




Volumn 18, Issue 5, 2012, Pages 413-417

Sample preparation for measurement of plasma mycophenolic acid concentrations using chromatographically functionalized magnetic micro-particles

Author keywords

Chromatography; Ferromagnetic micro particles; LC MS MS; Quantification; Sample preparation

Indexed keywords

AUTOMATION; CHROMATOGRAPHY; EXTRACTION; LIQUID CHROMATOGRAPHY; MAGNETISM; MASS SPECTROMETRY; PHASE SEPARATION;

EID: 84870901712     PISSN: None     EISSN: 17516838     Source Type: Journal    
DOI: 10.1255/ejms.1197     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 55049138550 scopus 로고    scopus 로고
    • Sample preparation for liquid chromatography-tandem mass spectrometry using functionalized ferromagnetic micro-particles
    • doi: 10.1016/j.clinbiochem.2008.08.001
    • M. Vogeser, A. Geiger, R. Herrmann and U. Kobold, "Sample preparation for liquid chromatography-tandem mass spectrometry using functionalized ferromagnetic micro-particles", Clin. Biochem. 41, 1417 (2008). doi: 10.1016/j.clinbiochem.2008.08.001
    • (2008) Clin. Biochem. , vol.41 , pp. 1417
    • Vogeser, M.1    Geiger, A.2    Herrmann, R.3    Kobold, U.4
  • 2
    • 80053984624 scopus 로고    scopus 로고
    • Magnetic separation as a new method for the extraction of small molecules from biological fluids of humans
    • doi: 10.1134/S1061934811090164
    • I.I. Sukhanova, M.A. Dikunets, E.D. Viryus and G.M. Rodchenkov, "Magnetic separation as a new method for the extraction of small molecules from biological fluids of humans", J. Anal. Chem. 66, 9:807-814 (2011). doi: 10.1134/S1061934811090164
    • (2011) J. Anal. Chem. , vol.66 , Issue.9 , pp. 807-814
    • Sukhanova, I.I.1    Dikunets, M.A.2    Viryus, E.D.3    Rodchenkov, G.M.4
  • 4
    • 33947396353 scopus 로고    scopus 로고
    • Standardized peptidome profiling of human urine by magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    • doi: 10.1373/clinchem.2006.077834
    • G.M. Fiedler, S. Baumann, A. Leichtle, A. Oltmann, J. Kase, J. Thiery and U. Ceglarek, "Standardized peptidome profiling of human urine by magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry", Clin. Chem. 53, 421 (2007).doi: 10.1373/clinchem.2006. 077834
    • (2007) Clin. Chem. , vol.53 , pp. 421
    • Fiedler, G.M.1    Baumann, S.2    Leichtle, A.3    Oltmann, A.4    Kase, J.5    Thiery, J.6    Ceglarek, U.7
  • 5
    • 84861713114 scopus 로고    scopus 로고
    • Extraction of viral nucleic acids: Comparison of five automated nucleic acid extraction platforms
    • doi: 10.1016/j.jcv.2012.03.008
    • J. Verheyen, R. Kaiser, M. Bozic, M. Timmen-Wego, B.K. Maier and H.H. Kessler, "Extraction of viral nucleic acids: comparison of five automated nucleic acid extraction platforms", J. Clin. Virol. 54, 255 (2012). doi: 10.1016/j.jcv.2012.03.008
    • (2012) J. Clin. Virol. , vol.54 , pp. 255
    • Verheyen, J.1    Kaiser, R.2    Bozic, M.3    Timmen-Wego, M.4    Maier, B.K.5    Kessler, H.H.6
  • 6
    • 78650650170 scopus 로고    scopus 로고
    • Recent advances in sample preparation techniques for effective bioanalytical methods
    • doi: 10.1002/bmc.156
    • P.L. Kole, G. Venkatesh, J. Kotecha and R. Sheshala, "Recent advances in sample preparation techniques for effective bioanalytical methods", Biomed. Chromatogr. 25, 199 (2011). doi: 10.1002/bmc.156
    • (2011) Biomed. Chromatogr. , vol.25 , pp. 199
    • Kole, P.L.1    Venkatesh, G.2    Kotecha, J.3    Sheshala, R.4
  • 7
    • 24044459791 scopus 로고    scopus 로고
    • Pitfall in the high-throughput quantification of whole blood cyclosporin A using liquid chromatography-tandem mass spectrometry
    • doi: 10.1515/CCLM.2005.072
    • M. Vogeser and U. Spohrer, "Pitfall in the high-throughput quantification of whole blood cyclosporin A using liquid chromatography-tandem mass spectrometry", Clin. Chem. Lab. Med. 43, 400 (2005). doi: 10.1515/CCLM.2005.072
    • (2005) Clin. Chem. Lab. Med. , vol.43 , pp. 400
    • Vogeser, M.1    Spohrer, U.2
  • 8
    • 43449083749 scopus 로고    scopus 로고
    • A decade of HPLC-MS/MS in the routine clinical laboratory - Goals for further developments
    • doi: 10.1016/j.clinbiochem.2008.02.017
    • M. Vogeser and C. Seger, "A decade of HPLC-MS/MS in the routine clinical laboratory - goals for further developments", Clin. Biochem. 41, 649 (2008). doi: 10.1016/j.clinbiochem.2008.02.017
    • (2008) Clin. Biochem. , vol.41 , pp. 649
    • Vogeser, M.1    Seger, C.2
  • 9
    • 84856509500 scopus 로고    scopus 로고
    • The role of liquid chromatography-tandem mass spectrometry in the clinical laboratory
    • doi: 10.1016/j.jchromb.2011.11.044
    • J.M. van den Ouweland and I.P. Kema, "The role of liquid chromatography-tandem mass spectrometry in the clinical laboratory", J. Chromatogr. B 883/884,1 (2012). doi: 10.1016/j.jchromb.2011.11.044
    • (2012) J. Chromatogr. B , vol.883-884 , pp. 1
    • Van Den Ouweland, J.M.1    Kema, I.P.2
  • 10
    • 8844222031 scopus 로고    scopus 로고
    • Determination of total mycophenolic acid and its glucuronide metabolite using liquid chromatography with ultraviolet detection and unbound mycophenolic acid using tandem mass spectrometry
    • doi: 10.1016/j.jchromb.2004.10.004
    • C.G. Patel, A.E. Mendonza, F. Akhlaghi, O. Majid, A.K. Trull, T. Lee and D.W. Holt, "Determination of total mycophenolic acid and its glucuronide metabolite using liquid chromatography with ultraviolet detection and unbound mycophenolic acid using tandem mass spectrometry", J. Chromatogr. B 813, 1-2:287-294 (2004). doi: 10.1016/j.jchromb.2004.10.004
    • (2004) J. Chromatogr. B , vol.813 , Issue.1-2 , pp. 287-294
    • Patel, C.G.1    Mendonza, A.E.2    Akhlaghi, F.3    Majid, O.4    Trull, A.K.5    Lee, T.6    Holt, D.W.7
  • 11
    • 17744386925 scopus 로고    scopus 로고
    • Quantification of mycophenolic acid and glucuronide metabolite in human serum by HPLC-tandem mass spectrometry
    • doi: 10.1373/clinchem.2004.047357
    • T.M. Annesley and L.T. Clayton, "Quantification of mycophenolic acid and glucuronide metabolite in human serum by HPLC-tandem mass spectrometry", Clin. Chem. 51, 872 (2005). doi: 10.1373/clinchem.2004. 047357
    • (2005) Clin. Chem. , vol.51 , pp. 872
    • Annesley, T.M.1    Clayton, L.T.2
  • 12
    • 84855601062 scopus 로고    scopus 로고
    • Validation of an LC-MS/MS method to determine five immunosuppressants with deuterated internal standards including MPA
    • doi: 10.1186/1472-6904-12-2
    • A. Buchwald, K. Winkler and T. Epting, "Validation of an LC-MS/MS method to determine five immunosuppressants with deuterated internal standards including MPA", BMC Clin. Pharmacol. 12, (2012), doi: 10.1186/1472-6904-12- 2
    • BMC Clin. Pharmacol. , vol.12 , pp. 2012
    • Buchwald, A.1    Winkler, K.2    Epting, T.3
  • 13
    • 23244442224 scopus 로고    scopus 로고
    • Validation of a high-performance liquid chromatography method for the measurement of mycophenolic acid and its glucuronide metabolites in plasma
    • doi: 10.1016/j.clinbiochem.2005.05.008
    • I.S. Westley, B.C. Sallustio and R.G. Morris, "Validation of a high-performance liquid chromatography method for the measurement of mycophenolic acid and its glucuronide metabolites in plasma", Clin. Biochem. 38, 824 (2005). doi: 10.1016/j.clinbiochem.2005.05.008
    • (2005) Clin. Biochem. , vol.38 , pp. 824
    • Westley, I.S.1    Sallustio, B.C.2    Morris, R.G.3
  • 14
    • 0035179487 scopus 로고    scopus 로고
    • Potential lack of specificity using electrospray tandem-mass spectrometry for the analysis of mycophenolic acid in serum
    • M. Vogeser, R. Zachoval, U. Spohrer and K. Jacob, "Potential lack of specificity using electrospray tandem-mass spectrometry for the analysis of mycophenolic acid in serum", Ther. Drug Monit. 23, 722 (2012).
    • (2012) Ther. Drug Monit. , vol.23 , pp. 722
    • Vogeser, M.1    Zachoval, R.2    Spohrer, U.3    Jacob, K.4
  • 15
    • 0038574979 scopus 로고    scopus 로고
    • Ion suppression in mass spectrometry
    • T.M. Annesley, "Ion suppression in mass spectrometry", Clin. Chem. 49, 1041 (2003).
    • (2003) Clin. Chem. , vol.49 , pp. 1041
    • Annesley, T.M.1
  • 16
    • 84861570767 scopus 로고    scopus 로고
    • Magnetic particle-linked anti hCG beta antibody for immunoassay of human chorionic gonadotropin (hCG), potential application to early pregnancy diagnosis
    • doi: 10.1016/j.jim.2012.04.006
    • H.T. Kuo, J.Z. Yeh, C.M. Jiang and M.C. Wu, "Magnetic particle-linked anti hCG beta antibody for immunoassay of human chorionic gonadotropin (hCG), potential application to early pregnancy diagnosis", J. Immunol. Methods 381, 32 (2012). doi: 10.1016/j.jim.2012.04.006
    • (2012) J. Immunol. Methods , vol.381 , pp. 32
    • Kuo, H.T.1    Yeh, J.Z.2    Jiang, C.M.3    Wu, M.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.