An ear-worn continuous ballistocardiogram (BCG) sensor for cardiovascular monitoring

Author keywords

[No Author keywords available]

Indexed keywords

CARDIAC CONTRACTILITY; CARDIOVASCULAR MONITORING; CLINICAL STUDY; FORM FACTORS; HEARING AID; HEART RATES; LINEAR CORRELATION; STATIONARY DEVICES; TRIAXIAL ACCELEROMETER;

EID: 84870814719     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2012.6347123     Document Type: Conference Paper
Times cited : (41)

References (14)
  • 1
    • 0013534815 scopus 로고
    • On certain molar movements of the human body produced by the circulation
    • J.W. Gordon, "On certain molar movements of the human body produced by the circulation," J. Anat. Physiol., 11:533-536, 1877.
    • (1877) J. Anat. Physiol. , vol.11 , pp. 533-536
    • Gordon, J.W.1
  • 2
    • 0013540061 scopus 로고
    • Studies on the estimation of cardiac output in man, and of abnormalities in cardiac function, from the heart's recoil and the blood's impacts; the ballistocardiogram
    • I. Starr, A.J. Rawson, H.A. Schroeder, and N.R. Joseph, "Studies on the estimation of cardiac output in man, and of abnormalities in cardiac function, from the heart's recoil and the blood's impacts; the ballistocardiogram," American J. Physiol., 127(1):1-28, 1939.
    • (1939) American J. Physiol. , vol.127 , Issue.1 , pp. 1-28
    • Starr, I.1    Rawson, A.J.2    Schroeder, H.A.3    Joseph, N.R.4
  • 3
    • 70249140625 scopus 로고    scopus 로고
    • Non-constrained monitoring of systolic blood pressure on a weighing scale
    • J.H. Shin, K.M. Lee, and K.S. Park, "Non-constrained monitoring of systolic blood pressure on a weighing scale," Physiol. Meas., 30:679-693, 2009.
    • (2009) Physiol. Meas. , vol.30 , pp. 679-693
    • Shin, J.H.1    Lee, K.M.2    Park, K.S.3
  • 4
    • 61849125182 scopus 로고    scopus 로고
    • Non-invasive measurement of valsalva-induced hemody-namic changes on a bathroom scale ballistocardiograph
    • Aug.
    • O.T. Inan, M. Etemadi, R.M. Wiard, G.T.A. Kovacs, and L. Giovangrandi, "Non-invasive Measurement of Valsalva-induced Hemody-namic Changes on a Bathroom Scale Ballistocardiograph," IEEE Eng. in Med. and Bio. Conf., p. 674-677, Aug. 2008.
    • (2008) IEEE Eng. in Med. and Bio. Conf. , pp. 674-677
    • Inan, O.T.1    Etemadi, M.2    Wiard, R.M.3    Kovacs, G.T.A.4    Giovangrandi, L.5
  • 6
    • 0014748171 scopus 로고
    • Left ventricular systolic time intervals as indices of postural circulatory stress in man
    • R.W. Stafford, W.S. Harris, and A.M. Weissler, "Left Ventricular Systolic Time Intervals as Indices of Postural Circulatory Stress in Man," Circulation, 41:485-492, 1970.
    • (1970) Circulation , vol.41 , pp. 485-492
    • Stafford, R.W.1    Harris, W.S.2    Weissler, A.M.3
  • 7
    • 49049105818 scopus 로고    scopus 로고
    • A new method for unconstrained pulse arrival time measurement on a chair
    • K.K. Kim et al., "A new method for unconstrained pulse arrival time measurement on a chair," J. Biomed. Eng. Res., 27:83-88, 2006.
    • (2006) J. Biomed. Eng. Res. , vol.27 , pp. 83-88
    • Kim, K.K.1
  • 9
    • 0036679097 scopus 로고    scopus 로고
    • Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI
    • G. Bonmassar et al., "Motion and Ballistocardiogram Artifact Removal for Interleaved Recording of EEG and EPs during MRI," NeuroImage, 16(4):1127-1141, 2001.
    • (2001) NeuroImage , vol.16 , Issue.4 , pp. 1127-1141
    • Bonmassar, G.1
  • 10
    • 0037687974 scopus 로고    scopus 로고
    • Quality of EEG in simultaneous EEG-fMRI for epilepsy
    • C-G. Benar et al., "Quality of EEG in simultaneous EEG-fMRI for epilepsy," Clinical Neurophysiology, 114(3):569-580, 2003.
    • (2003) Clinical Neurophysiology , vol.114 , Issue.3 , pp. 569-580
    • Benar, C.-G.1
  • 12
    • 84863606848 scopus 로고    scopus 로고
    • A continuous, wearable, and wireless heart monitor using head ballistocardiogram (BCG) and head electrocardiogram (ECG)
    • Sept.
    • D. He, E.S. Winokur, and C.G. Sodini, "A continuous, wearable, and wireless heart monitor using head ballistocardiogram (BCG) and head electrocardiogram (ECG)," IEEE Eng. in Med. and Bio. Conf., p.4729-4732, Sept. 2011.
    • (2011) IEEE Eng. in Med. and Bio. Conf. , pp. 4729-4732
    • He, D.1    Winokur, E.S.2    Sodini, C.G.3
  • 13
    • 78649277118 scopus 로고
    • Grune and Stratton, Inc., New York, NY, USA
    • A.M. Weissler, Noninvasive Cardiology, Grune and Stratton, Inc., New York, NY, USA, 1974.
    • (1974) Noninvasive Cardiology
    • Weissler, A.M.1
  • 14
    • 77954684729 scopus 로고    scopus 로고
    • Beat-by-beat changes in pre-ejection period during functional tests evaluated by impedance aortography: A step to a left ventricular contractility monitoring
    • V.V. Ermishkin et al., "Beat-by-beat changes in pre-ejection period during functional tests evaluated by impedance aortography: a step to a left ventricular contractility monitoring," Int'l Conf. Elec. Bioimpedance, 17(14):655-658, 2007.
    • (2007) Int'l Conf. Elec. Bioimpedance , vol.17 , Issue.14 , pp. 655-658
    • Ermishkin, V.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.