메뉴 건너뛰기




Volumn 102, Issue , 2013, Pages 364-373

Single and double U-tube ground heat exchangers in multiple-layer substrates

Author keywords

GHE; Ground heat exchangers; Heat pump; Multiple layer ground; U tube

Indexed keywords

HEAT PUMP SYSTEMS; PARTIAL DIFFERENTIAL EQUATIONS;

EID: 84870762103     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2012.07.035     Document Type: Article
Times cited : (101)

References (29)
  • 1
    • 23044471439 scopus 로고    scopus 로고
    • Shallow geothermal energy
    • Sanner B. Shallow geothermal energy. Geo-Heat Center Quart Bull 2001, 22(2):19-25. .
    • (2001) Geo-Heat Center Quart Bull , vol.22 , Issue.2 , pp. 19-25
    • Sanner, B.1
  • 2
    • 35548967503 scopus 로고    scopus 로고
    • Ground heat exchangers: a review of systems, models and applications
    • Florides G., Kalogirou S. Ground heat exchangers: a review of systems, models and applications. Renew Energy 2007, 32(15):2461-2478.
    • (2007) Renew Energy , vol.32 , Issue.15 , pp. 2461-2478
    • Florides, G.1    Kalogirou, S.2
  • 3
    • 79961173502 scopus 로고    scopus 로고
    • The geothermal characteristics of the ground and the potential of using ground coupled heat pumps in Cyprus
    • Florides G.A., Pouloupatis P.D., Kalogirou S., Messaritis V., Panayides I., Zomeni Z., et al. The geothermal characteristics of the ground and the potential of using ground coupled heat pumps in Cyprus. Energy 2011, 36:5027-5036.
    • (2011) Energy , vol.36 , pp. 5027-5036
    • Florides, G.A.1    Pouloupatis, P.D.2    Kalogirou, S.3    Messaritis, V.4    Panayides, I.5    Zomeni, Z.6
  • 4
    • 85020993849 scopus 로고    scopus 로고
    • GeoLink Design Studio
    • GeoLink Design Studio http://www.waterfurnace.com/GDS/.
  • 5
    • 85021023298 scopus 로고    scopus 로고
    • Ground Loop Design
    • Ground Loop Design. http://www.gaiageo.com/.
  • 6
    • 84870766497 scopus 로고    scopus 로고
    • HYDROTHERM
    • HYDROTHERM http://wwwbrr.cr.usgs.gov/projects/GW_Solute/hydrotherm/.
  • 7
    • 84870734108 scopus 로고    scopus 로고
    • LoopLink
    • LoopLink http://www.geoconnectionsinc.com/software/software.htm.
  • 8
    • 84870740688 scopus 로고    scopus 로고
    • SVHeat
    • SVHeat http://www.soilvision.com/subdomains/svheat.com/index.shtml.
  • 9
    • 84870749312 scopus 로고    scopus 로고
    • TEMP/W
    • TEMP/W. http://www.geo-slope.com/products/tempw2007.aspx.
  • 10
    • 84870750685 scopus 로고    scopus 로고
    • GS2000
    • GS2000. http://www.198.103.48.154/eng/software_tools/gs2000.html.
  • 11
    • 0001848789 scopus 로고
    • Theory of the ground pipe heat source for the heat pump
    • Ingersoll L.R., Plass H.J. Theory of the ground pipe heat source for the heat pump. Heat Pip Air Cond 1948, 20(7):119-122.
    • (1948) Heat Pip Air Cond , vol.20 , Issue.7 , pp. 119-122
    • Ingersoll, L.R.1    Plass, H.J.2
  • 13
    • 0029489615 scopus 로고
    • A design method for commercial ground-coupled heat pumps
    • Kavanaugh S. A design method for commercial ground-coupled heat pumps. ASHRAE Trans 1995, 101(2):1088-1094.
    • (1995) ASHRAE Trans , vol.101 , Issue.2 , pp. 1088-1094
    • Kavanaugh, S.1
  • 14
    • 0034832568 scopus 로고    scopus 로고
    • Ground-coupled heat pump system simulation
    • Bernier M.A. Ground-coupled heat pump system simulation. ASHRAE Trans 2001, 106(1):605-616.
    • (2001) ASHRAE Trans , vol.106 , Issue.1 , pp. 605-616
    • Bernier, M.A.1
  • 15
    • 64649091127 scopus 로고    scopus 로고
    • A two-region simulation model of vertical U-tube ground heat exchanger and its experimental verification
    • Yang W., Shi M., Liu G., Chen Z. A two-region simulation model of vertical U-tube ground heat exchanger and its experimental verification. Appl Energy 2009, 86(10):2005-2012.
    • (2009) Appl Energy , vol.86 , Issue.10 , pp. 2005-2012
    • Yang, W.1    Shi, M.2    Liu, G.3    Chen, Z.4
  • 16
    • 0023981103 scopus 로고
    • Simulation model for thermally interacting heat extraction boreholes
    • Eskilson P., Claesson J. Simulation model for thermally interacting heat extraction boreholes. Numer Heat Transfer 1988, 13:149-165.
    • (1988) Numer Heat Transfer , vol.13 , pp. 149-165
    • Eskilson, P.1    Claesson, J.2
  • 17
    • 0042830430 scopus 로고    scopus 로고
    • Heat transfer analysis of boreholes in vertical ground heat exchangers
    • Zeng H.Y., Diao N.R., Fang Z.H. Heat transfer analysis of boreholes in vertical ground heat exchangers. Int J Heat Mass Transfer 2003, 46(23):4467-4481.
    • (2003) Int J Heat Mass Transfer , vol.46 , Issue.23 , pp. 4467-4481
    • Zeng, H.Y.1    Diao, N.R.2    Fang, Z.H.3
  • 18
    • 80052259146 scopus 로고    scopus 로고
    • Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation
    • Lee C.K. Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation. Appl Energy 2011, 88(12):4405-4410.
    • (2011) Appl Energy , vol.88 , Issue.12 , pp. 4405-4410
    • Lee, C.K.1
  • 19
    • 84862309697 scopus 로고    scopus 로고
    • Examination of thermal interaction of multiple vertical ground heat exchangers
    • (14 March 2012)
    • Koohi-Fayegh S, Rosen MA. Examination of thermal interaction of multiple vertical ground heat exchangers. Appl Energy 2012 (14 March 2012).
    • (2012) Appl Energy
    • Koohi-Fayegh, S.1    Rosen, M.A.2
  • 21
    • 0033309869 scopus 로고    scopus 로고
    • A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers
    • Yavuzturk C., Spitler J.D., Rees S.J. A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers. ASHRAE Trans 1999, 105(2):465-474.
    • (1999) ASHRAE Trans , vol.105 , Issue.2 , pp. 465-474
    • Yavuzturk, C.1    Spitler, J.D.2    Rees, S.J.3
  • 22
    • 64649101392 scopus 로고    scopus 로고
    • Predicting the fluid temperature at the exit of the vertical ground heat exchangers
    • Michopoulos A., Kyriakis N. Predicting the fluid temperature at the exit of the vertical ground heat exchangers. Appl Energy 2009, 86(10):2065-2070.
    • (2009) Appl Energy , vol.86 , Issue.10 , pp. 2065-2070
    • Michopoulos, A.1    Kyriakis, N.2
  • 23
    • 84055214185 scopus 로고    scopus 로고
    • An analysis of heat flow through a borehole heat exchanger validated model
    • Florides G.A., Christodoulides P., Pouloupatis P. An analysis of heat flow through a borehole heat exchanger validated model. Appl Energy 2012, 92:523-533.
    • (2012) Appl Energy , vol.92 , pp. 523-533
    • Florides, G.A.1    Christodoulides, P.2    Pouloupatis, P.3
  • 24
    • 70349437017 scopus 로고    scopus 로고
    • Vertical-borehole ground-coupled heat pumps: a review of models and systems
    • Yang H., Cui P., Fang Z. Vertical-borehole ground-coupled heat pumps: a review of models and systems. Appl Energy 2010, 87(1):16-27.
    • (2010) Appl Energy , vol.87 , Issue.1 , pp. 16-27
    • Yang, H.1    Cui, P.2    Fang, Z.3
  • 25
    • 0036459671 scopus 로고    scopus 로고
    • An algorithm for approximating the performance of vertical bore heat exchangers installed in a stratified geological regime
    • Sutton M.G., Couvillion R.J., Nutter D.W., Davis R.K. An algorithm for approximating the performance of vertical bore heat exchangers installed in a stratified geological regime. SHRAE Trans 2002, 108(2):177-184.
    • (2002) SHRAE Trans , vol.108 , Issue.2 , pp. 177-184
    • Sutton, M.G.1    Couvillion, R.J.2    Nutter, D.W.3    Davis, R.K.4
  • 26
  • 27
    • 84870736760 scopus 로고    scopus 로고
    • Techno-economic analysis of single U-tube and double U-tube heat exchangers in Chongqing area
    • Wang Y., Guo K.S., Tian R., Han C.P., Lai D.X., Xu F. Techno-economic analysis of single U-tube and double U-tube heat exchangers in Chongqing area. J Central South Univ Technol 2009, 16:244-248.
    • (2009) J Central South Univ Technol , vol.16 , pp. 244-248
    • Wang, Y.1    Guo, K.S.2    Tian, R.3    Han, C.P.4    Lai, D.X.5    Xu, F.6
  • 28
    • 33745651620 scopus 로고    scopus 로고
    • Heat performance research and economical analysis of single U-shaped and double U-shaped vertical borehole heat exchanger
    • Xue Y, Ji M, Li X, Zhao. Heat performance research and economical analysis of single U-shaped and double U-shaped vertical borehole heat exchanger. Acta Energiae Solaris Sinica 2006;4-18.
    • (2006) Acta Energiae Solaris Sinica , pp. 4-18
    • Xue, Y.1    Ji, M.2    Li, X.3    Zhao4
  • 29
    • 85021043704 scopus 로고    scopus 로고
    • FlexPDE 6 Manual 2010. PDE Solutions Inc. Spokane Valley, WA 99206
    • FlexPDE 6 Manual 2010. PDE Solutions Inc. Spokane Valley, WA 99206. http://www.pdesolutions.com.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.