메뉴 건너뛰기




Volumn 78, Issue 6, 2012, Pages 651-657

Intraoperative dual monitoring during carotid endarterectomy using motor evoked potentials and near-infrared spectroscopy

Author keywords

Carotid endarterectomy; Cerebral ischemia; Intraoperative monitoring; Motor evoked potential; Near infrared spectroscopy

Indexed keywords

ADULT; AGED; ARTERY CLAMP; BRAIN INFARCTION; BRAIN ISCHEMIA; BRAIN REGION; CAROTID ARTERY; CAROTID ARTERY OBSTRUCTION; CAROTID ENDARTERECTOMY; CEREBROVASCULAR ACCIDENT; CLINICAL ARTICLE; CRITICAL CEREBRAL ISCHEMIA; EVOKED MUSCLE RESPONSE; FEMALE; FOREHEAD; FRONTAL LOBE; HUMAN; MALE; MOTOR DYSFUNCTION; NEAR INFRARED SPECTROSCOPY; OXYGEN TISSUE LEVEL; PATIENT MONITORING; REVIEW; TREATMENT OUTCOME; VALIDITY;

EID: 84870494543     PISSN: 18788750     EISSN: 18788769     Source Type: Journal    
DOI: 10.1016/j.wneu.2011.10.039     Document Type: Review
Times cited : (25)

References (38)
  • 1
    • 0025734372 scopus 로고
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators N Engl J Med 325 1991 445 453
    • (1991) N Engl J Med , vol.325 , pp. 445-453
  • 2
    • 0028938324 scopus 로고
    • Endarterectomy for asymptomatic carotid artery stenosis Executive Committee for the Asymptomatic Carotid Atherosclerosis Study
    • Endarterectomy for asymptomatic carotid artery stenosis Executive Committee for the Asymptomatic Carotid Atherosclerosis Study JAMA 273 1995 1421 1428
    • (1995) JAMA , vol.273 , pp. 1421-1428
  • 3
    • 0000252673 scopus 로고
    • MRC European Carotid Surgery Trial: Interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis European Carotid Surgery Trialists' Collaborative Group
    • MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis European Carotid Surgery Trialists' Collaborative Group Lancet 337 1991 1235 1243
    • (1991) Lancet , vol.337 , pp. 1235-1243
  • 4
    • 0027483253 scopus 로고
    • Cerebral blood flow during carotid endarterectomy determined by three dimensional SPECT measurement; Relation to preoperative risk assessment
    • L. Algotsson, E. Ryding, S. Rehncrona, K. Messeter Cerebral blood flow during carotid endarterectomy determined by three dimensional SPECT measurement; relation to preoperative risk assessment Eur J Vasc Surg 7 1993 46 53
    • (1993) Eur J Vasc Surg , vol.7 , pp. 46-53
    • Algotsson, L.1    Ryding, E.2    Rehncrona, S.3    Messeter, K.4
  • 5
    • 0016302747 scopus 로고
    • Relationship between the cortical evoked potential and local cortical blood flow following acute middle cerebral artery occlusion in the baboon
    • N.M. Branston, L. Symon, H.A. Crockard, E. Pasztor Relationship between the cortical evoked potential and local cortical blood flow following acute middle cerebral artery occlusion in the baboon Exp Neurol 45 1974 195 208
    • (1974) Exp Neurol , vol.45 , pp. 195-208
    • Branston, N.M.1    Symon, L.2    Crockard, H.A.3    Pasztor, E.4
  • 6
    • 0031661789 scopus 로고    scopus 로고
    • Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy
    • H. Cho, E.M. Nemoto, H. Yonas, J. Balzer, R.J. Sclabassi Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy J Neurosurg 89 1998 533 538
    • (1998) J Neurosurg , vol.89 , pp. 533-538
    • Cho, H.1    Nemoto, E.M.2    Yonas, H.3    Balzer, J.4    Sclabassi, R.J.5
  • 7
    • 0035723347 scopus 로고    scopus 로고
    • Transcranial electrical motor evoked potential monitoring for brain tumor resection
    • V. Deletis, A.B. Camargo Transcranial electrical motor evoked potential monitoring for brain tumor resection Neurosurgery 49 2001 1488 1489
    • (2001) Neurosurgery , vol.49 , pp. 1488-1489
    • Deletis, V.1    Camargo, A.B.2
  • 9
    • 0025953483 scopus 로고
    • Monitoring of somatosensory evoked potentials during surgery for middle cerebral artery aneurysms
    • W.A. Friedman, G.M. Chadwick, F.J. Verhoeven, M. Mahla, A.L. Day Monitoring of somatosensory evoked potentials during surgery for middle cerebral artery aneurysms Neurosurgery 29 1991 83 88
    • (1991) Neurosurgery , vol.29 , pp. 83-88
    • Friedman, W.A.1    Chadwick, G.M.2    Verhoeven, F.J.3    Mahla, M.4    Day, A.L.5
  • 10
    • 0031737806 scopus 로고    scopus 로고
    • Transcranial Doppler: Preventing stroke during carotid endarterectomy
    • M.E. Gaunt Transcranial Doppler: preventing stroke during carotid endarterectomy Ann R Coll Surg Engl 80 1998 377 387
    • (1998) Ann R Coll Surg Engl , vol.80 , pp. 377-387
    • Gaunt, M.E.1
  • 11
    • 2342492418 scopus 로고    scopus 로고
    • Prevention of disabling and fatal strokes by successful carotid endarterectomy in patients without recent neurological symptoms: Randomised controlled trial
    • A. Halliday, A. Mansfield, J. Marro, C. Peto, R. Peto, J. Potter, D. Thomas Prevention of disabling and fatal strokes by successful carotid endarterectomy in patients without recent neurological symptoms: randomised controlled trial Lancet 363 2004 1491 1502
    • (2004) Lancet , vol.363 , pp. 1491-1502
    • Halliday, A.1    Mansfield, A.2    Marro, J.3    Peto, C.4    Peto, R.5    Potter, J.6    Thomas, D.7
  • 13
    • 78650709723 scopus 로고    scopus 로고
    • Clinical characteristics and outcomes in carotid endarterectomy for internal carotid artery stenosis in a Japanese population: 10-year microsurgical experience
    • M. Iwasaki, S. Kuroda, N. Nakayama, M. Hokari, H. Yasuda, H. Saito, Y. Iwasaki Clinical characteristics and outcomes in carotid endarterectomy for internal carotid artery stenosis in a Japanese population: 10-year microsurgical experience J Stroke Cerebrovasc Dis 20 2011 55 61
    • (2011) J Stroke Cerebrovasc Dis , vol.20 , pp. 55-61
    • Iwasaki, M.1    Kuroda, S.2    Nakayama, N.3    Hokari, M.4    Yasuda, H.5    Saito, H.6    Iwasaki, Y.7
  • 14
    • 25144436909 scopus 로고    scopus 로고
    • Effects of carotid endarterectomy on motor evoked potentials elicited by transcranial magnetic stimulation
    • G. Katsoulas, I. Tsolakis, A.A. Argyriou, P. Polychronopoulos, M. Argentou, E. Chroni Effects of carotid endarterectomy on motor evoked potentials elicited by transcranial magnetic stimulation J Neurol 252 2005 1050 1054
    • (2005) J Neurol , vol.252 , pp. 1050-1054
    • Katsoulas, G.1    Tsolakis, I.2    Argyriou, A.A.3    Polychronopoulos, P.4    Argentou, M.5    Chroni, E.6
  • 15
    • 73449093480 scopus 로고    scopus 로고
    • Doppler embolic signals in cerebrovascular disease and prediction of stroke risk: A systematic review and meta-analysis
    • A. King, H.S. Markus Doppler embolic signals in cerebrovascular disease and prediction of stroke risk: a systematic review and meta-analysis Stroke 40 2009 3711 3717
    • (2009) Stroke , vol.40 , pp. 3711-3717
    • King, A.1    Markus, H.S.2
  • 16
    • 0034766801 scopus 로고    scopus 로고
    • Monitoring of intraoperative motor evoked potentials to increase the safety of surgery in and around the motor cortex
    • T. Kombos, O. Suess, O. Ciklatekerlio, M. Brock Monitoring of intraoperative motor evoked potentials to increase the safety of surgery in and around the motor cortex J Neurosurg 95 2001 608 614
    • (2001) J Neurosurg , vol.95 , pp. 608-614
    • Kombos, T.1    Suess, O.2    Ciklatekerlio, O.3    Brock, M.4
  • 17
    • 0026785960 scopus 로고
    • Pure motor hemiparesis with stable somatosensory evoked potential monitoring during aneurysm surgery: Case report
    • D. Krieger, H.P. Adams, F. Albert, M. von Haken, W. Hacke Pure motor hemiparesis with stable somatosensory evoked potential monitoring during aneurysm surgery: case report Neurosurgery 31 1992 145 150
    • (1992) Neurosurgery , vol.31 , pp. 145-150
    • Krieger, D.1    Adams, H.P.2    Albert, F.3    Von Haken, M.4    Hacke, W.5
  • 19
    • 0029879420 scopus 로고    scopus 로고
    • Near-infrared monitoring of cerebral oxygenation state during carotid endarterectomy
    • S. Kuroda, K. Houkin, H. Abe, Y. Hoshi, M. Tamura Near-infrared monitoring of cerebral oxygenation state during carotid endarterectomy Surg Neurol 45 1996 450 458
    • (1996) Surg Neurol , vol.45 , pp. 450-458
    • Kuroda, S.1    Houkin, K.2    Abe, H.3    Hoshi, Y.4    Tamura, M.5
  • 20
    • 0030042844 scopus 로고    scopus 로고
    • Cerebral hemodynamic changes during carotid artery balloon occlusion monitored by near-infrared spectroscopy
    • S. Kuroda, K. Houkin, H. Abe, M. Tamura Cerebral hemodynamic changes during carotid artery balloon occlusion monitored by near-infrared spectroscopy Neurol Med Chir (Tokyo) 36 1996 78 86
    • (1996) Neurol Med Chir (Tokyo) , vol.36 , pp. 78-86
    • Kuroda, S.1    Houkin, K.2    Abe, H.3    Tamura, M.4
  • 21
    • 0023173032 scopus 로고
    • Clinical experience with motor and cerebellar evoked potential monitoring
    • W.J. Levy Jr Clinical experience with motor and cerebellar evoked potential monitoring Neurosurgery 20 1987 169 182
    • (1987) Neurosurgery , vol.20 , pp. 169-182
    • Levy, Jr.W.J.1
  • 22
    • 0017132172 scopus 로고
    • Internal carotid artery stump pressure and cerebral blood flow during carotid endarterectomy: Modification by halothane, enflurane, and innovar
    • R.D. McKay, T.M. Sundt, J.D. Michenfelder, G.A. Gronert, J.M. Messick, F.W. Sharbrough, D.G. Piepgras Internal carotid artery stump pressure and cerebral blood flow during carotid endarterectomy: modification by halothane, enflurane, and innovar Anesthesiology 45 1976 390 399
    • (1976) Anesthesiology , vol.45 , pp. 390-399
    • McKay, R.D.1    Sundt, T.M.2    Michenfelder, J.D.3    Gronert, G.A.4    Messick, J.M.5    Sharbrough, F.W.6    Piepgras, D.G.7
  • 24
    • 0028850124 scopus 로고
    • A new method of multisegment motor pathway monitoring using muscle potentials after train spinal stimulation
    • K. Mochida, K. Shinomiya, H. Komori, K. Furuya A new method of multisegment motor pathway monitoring using muscle potentials after train spinal stimulation Spine 20 1995 2240 2246
    • (1995) Spine , vol.20 , pp. 2240-2246
    • Mochida, K.1    Shinomiya, K.2    Komori, H.3    Furuya, K.4
  • 25
    • 34748889901 scopus 로고    scopus 로고
    • Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: A comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials
    • S. Moritz, P. Kasprzak, M. Arlt, K. Taeger, C. Metz Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials Anesthesiology 107 2007 563 569
    • (2007) Anesthesiology , vol.107 , pp. 563-569
    • Moritz, S.1    Kasprzak, P.2    Arlt, M.3    Taeger, K.4    Metz, C.5
  • 26
    • 0030786736 scopus 로고    scopus 로고
    • The role of motor evoked potentials during surgery for intramedullary spinal cord tumors
    • N. Morota, V. Deletis, S. Constantini, M. Kofler, H. Cohen, F.J. Epstein The role of motor evoked potentials during surgery for intramedullary spinal cord tumors Neurosurgery 41 1997 1327 1336
    • (1997) Neurosurgery , vol.41 , pp. 1327-1336
    • Morota, N.1    Deletis, V.2    Constantini, S.3    Kofler, M.4    Cohen, H.5    Epstein, F.J.6
  • 27
    • 0026774748 scopus 로고
    • Monitoring and cerebral protection during carotid endarterectomy
    • A.R. Naylor, P.R. Bell, C.V. Ruckley Monitoring and cerebral protection during carotid endarterectomy Br J Surg 79 1992 735 741
    • (1992) Br J Surg , vol.79 , pp. 735-741
    • Naylor, A.R.1    Bell, P.R.2    Ruckley, C.V.3
  • 28
    • 2342578727 scopus 로고    scopus 로고
    • Motor evoked potential monitoring with supratentorial surgery
    • discussion 1070-1062
    • G. Neuloh, U. Pechstein, C. Cedzich, J. Schramm Motor evoked potential monitoring with supratentorial surgery Neurosurgery 54 2004 1061 1070 discussion 1070-1062
    • (2004) Neurosurgery , vol.54 , pp. 1061-1070
    • Neuloh, G.1    Pechstein, U.2    Cedzich, C.3    Schramm, J.4
  • 29
    • 1442282523 scopus 로고    scopus 로고
    • Monitoring of motor evoked potentials compared with somatosensory evoked potentials and microvascular Doppler ultrasonography in cerebral aneurysm surgery
    • G. Neuloh, J. Schramm Monitoring of motor evoked potentials compared with somatosensory evoked potentials and microvascular Doppler ultrasonography in cerebral aneurysm surgery J Neurosurg 100 2004 389 399
    • (2004) J Neurosurg , vol.100 , pp. 389-399
    • Neuloh, G.1    Schramm, J.2
  • 30
    • 1842862845 scopus 로고    scopus 로고
    • Motor evoked potential monitoring for the surgery of brain tumours and vascular malformations
    • G. Neuloh, J. Schramm Motor evoked potential monitoring for the surgery of brain tumours and vascular malformations Adv Tech Stand Neurosurg 29 2004 171 228
    • (2004) Adv Tech Stand Neurosurg , vol.29 , pp. 171-228
    • Neuloh, G.1    Schramm, J.2
  • 31
    • 0032249054 scopus 로고    scopus 로고
    • Continuous monitoring of jugular bulb venous oxygen saturation for evaluation of cerebral perfusion during carotid endarterectomy
    • H. Niinai, I. Nakagawa, T. Shima, M. Kawamoto, O. Yuge Continuous monitoring of jugular bulb venous oxygen saturation for evaluation of cerebral perfusion during carotid endarterectomy Hiroshima J Med Sci 47 1998 133 137
    • (1998) Hiroshima J Med Sci , vol.47 , pp. 133-137
    • Niinai, H.1    Nakagawa, I.2    Shima, T.3    Kawamoto, M.4    Yuge, O.5
  • 32
    • 33846234704 scopus 로고    scopus 로고
    • High-frequency monopolar electrical stimulation of the rat cerebral cortex
    • discussion 196-187
    • M. Oinuma, K. Suzuki, T. Honda, M. Matsumoto, T. Sasaki, N. Kodama High-frequency monopolar electrical stimulation of the rat cerebral cortex Neurosurgery 60 2007 189 196 discussion 196-187
    • (2007) Neurosurgery , vol.60 , pp. 189-196
    • Oinuma, M.1    Suzuki, K.2    Honda, T.3    Matsumoto, M.4    Sasaki, T.5    Kodama, N.6
  • 33
    • 70449715508 scopus 로고    scopus 로고
    • The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention A review
    • C.W. Pennekamp, M.L. Bots, L.J. Kappelle, F.L. Moll, G.J. de Borst The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention A review Eur J Vasc Endovasc Surg 38 2009 539 545
    • (2009) Eur J Vasc Endovasc Surg , vol.38 , pp. 539-545
    • Pennekamp, C.W.1    Bots, M.L.2    Kappelle, L.J.3    Moll, F.L.4    De Borst, G.J.5
  • 35
    • 0033779446 scopus 로고    scopus 로고
    • Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy
    • S.K. Samra, E.A. Dy, K. Welch, P. Dorje, G.B. Zelenock, J.C. Stanley Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy Anesthesiology 93 2000 964 970
    • (2000) Anesthesiology , vol.93 , pp. 964-970
    • Samra, S.K.1    Dy, E.A.2    Welch, K.3    Dorje, P.4    Zelenock, G.B.5    Stanley, J.C.6
  • 37
    • 36849091063 scopus 로고    scopus 로고
    • Transcranial and direct cortical stimulation for motor evoked potential monitoring in intracerebral aneurysm surgery
    • A. Szelenyi, D. Langer, J. Beck, A. Raabe, E.S. Flamm, V. Seifert, V. Deletis Transcranial and direct cortical stimulation for motor evoked potential monitoring in intracerebral aneurysm surgery Neurophysiol Clin 37 2007 391 398
    • (2007) Neurophysiol Clin , vol.37 , pp. 391-398
    • Szelenyi, A.1    Langer, D.2    Beck, J.3    Raabe, A.4    Flamm, E.S.5    Seifert, V.6    Deletis, V.7
  • 38
    • 33847769923 scopus 로고    scopus 로고
    • Combined motor and somatosensory evoked potentials for intraoperative monitoring: Intra- and postoperative data in a series of 69 operations
    • discussion 116
    • M.R. Weinzierl, P. Reinacher, J.M. Gilsbach, V. Rohde Combined motor and somatosensory evoked potentials for intraoperative monitoring: intra- and postoperative data in a series of 69 operations Neurosurg Rev 30 2007 109 116 discussion 116
    • (2007) Neurosurg Rev , vol.30 , pp. 109-116
    • Weinzierl, M.R.1    Reinacher, P.2    Gilsbach, J.M.3    Rohde, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.