메뉴 건너뛰기




Volumn 40, Issue 10, 2012, Pages 913-916

Analysis of the air/water channels of gastrointestinal endoscopies as a risk factor for the transmission of microorganisms among patients

Author keywords

Contamination; Effectiveness; Endoscope; Reprocessing

Indexed keywords

ACINETOBACTER BAUMANNII; AIR SAMPLING; ARTICLE; BACTERIAL TRANSMISSION; BACTERIUM ISOLATION; BRAZIL; COLONOSCOPE; COLONY FORMING UNIT; CROSS-SECTIONAL STUDY; DIGESTIVE ENDOSCOPE; ENDOSCOPE; ESCHERICHIA COLI; GASTROSCOPE; INSTRUMENT STERILIZATION; KLEBSIELLA PNEUMONIAE; MICROBIAL CONTAMINATION; NONHUMAN; PATHOGEN LOAD; PSEUDOMONAS AERUGINOSA; RISK; RISK FACTOR; WATER SAMPLING;

EID: 84870467123     PISSN: 01966553     EISSN: 15273296     Source Type: Journal    
DOI: 10.1016/j.ajic.2012.02.005     Document Type: Article
Times cited : (26)

References (15)
  • 1
    • 79957789580 scopus 로고    scopus 로고
    • Multisociety guideline on reprocessing flexible gastrointestinal endoscopes
    • American Society for Gastrointestinal Endoscopy; Society For Healthcare Epidemiology of America
    • American Society for Gastrointestinal Endoscopy; Society For Healthcare Epidemiology of America Multisociety guideline on reprocessing flexible gastrointestinal endoscopes Gastrointest Endosc 73 2011 1075 1084
    • (2011) Gastrointest Endosc , vol.73 , pp. 1075-1084
  • 2
    • 20144371523 scopus 로고    scopus 로고
    • Contamination with hepatitis B virus DNA in gastrointestinal endoscope channels: Risk of infection on reuse after on-site cleaning
    • DOI 10.1055/s-2005-861316
    • Y. Ishino, K. Ido, and K. Sugano Contamination with hepatitis B virus DNA in gastrointestinal endoscope channels: risk of infection on reuse after on-site cleaning Endoscopy 37 2005 548 551 (Pubitemid 40775239)
    • (2005) Endoscopy , vol.37 , Issue.6 , pp. 548-551
    • Ishino, Y.1    Ido, K.2    Sugano, K.3
  • 3
    • 18844426232 scopus 로고    scopus 로고
    • Real-time monitoring in managing the decontamination of flexible gastrointestinal endoscopes
    • DOI 10.1016/j.ajic.2004.07.008, PII S0196655304005668
    • P.C. Obee, C.J. Griffith, R.A. Cooper, R.P. Coode, N.E. Bennion, and M. Lewis Real-time monitoring in managing the contamination of flexible gastrointestinal endoscopes Am J Infect Control 33 2005 202 206 (Pubitemid 40692317)
    • (2005) American Journal of Infection Control , vol.33 , Issue.4 , pp. 202-206
    • Obee, P.C.1    Griffith, C.J.2    Cooper, R.A.3    Cooke, R.P.4    Bennion, N.E.5    Lewis, M.6
  • 4
    • 0036221219 scopus 로고    scopus 로고
    • A survey of reprocessing methods, residual viable bioburden, and soil levels in patient-ready endoscopic retrograde choliangiopancreatography duodenoscopes used in Canadian centers
    • M.J. Alfa, N. Olson, P. Degagne, and M. Jackson A survey of reprocessing methods, residual viable bioburden, and soil levels in patient-ready endoscopic retrograde choliangiopancreatography duodenoscopes used in Canadian centres Infect Control Hosp Epidemiol 23 2002 198 206 (Pubitemid 34297273)
    • (2002) Infection Control and Hospital Epidemiology , vol.23 , Issue.4 , pp. 198-206
    • Alfa, M.J.1    Olson, N.2    DeGagne, P.3    Jackson, M.4
  • 5
    • 56749104971 scopus 로고    scopus 로고
    • ESGE-ESGENA guideline: Cleaning and disinfection in gastrointestinal endoscopy
    • European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee
    • U. Beilenhoff, C.S. Neumann, J.F. Rey, H. Biering, R. Blum, M. Cimbro European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee ESGE-ESGENA guideline: cleaning and disinfection in gastrointestinal endoscopy Endoscopy 40 2008 939 957
    • (2008) Endoscopy , vol.40 , pp. 939-957
    • Beilenhoff, U.1    Neumann, C.S.2    Rey, J.F.3    Biering, H.4    Blum, R.5    Cimbro, M.6
  • 6
    • 33947136836 scopus 로고    scopus 로고
    • ESGE-ESGENA guideline for quality assurance in reprocessing: Microbiological surveillance testing in endoscopy
    • DOI 10.1055/s-2006-945181
    • U. Beilenhoff, C.S. Neumann, J.F. Rey, H. Biering, V. Schmidt European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee ESGE-ESGENA guideline for quality assurance in reprocessing: microbiological surveillance testing in endoscopy Endoscopy 39 2007 175 181 (Pubitemid 46394834)
    • (2007) Endoscopy , vol.39 , Issue.2 , pp. 175-181
    • Beilenhoff, U.1    Neumann, C.S.2    Rey, J.F.3    Biering, H.4    Blum, R.5    Schmidt, V.6
  • 7
    • 84870432878 scopus 로고    scopus 로고
    • Brazilian Society of Endoscopy Nursing Grastrointestinal, Ministry of Health, National Agency of Sanitary Surveillance Accessed May 14
    • Brazilian Society of Endoscopy Nursing Grastrointestinal, Ministry of Health, National Agency of Sanitary Surveillance. Manual Cleaning and Disinfection of Endoscopes Equipment. Available from: http://www.anvisa.gov.br/ servicosaude/manuais/sobeeg-manual.pdf. Accessed May 14, 2012.
    • (2012) Manual Cleaning and Disinfection of Endoscopes Equipment
  • 8
    • 7744243890 scopus 로고    scopus 로고
    • Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination?
    • DOI 10.1016/j.jhin.2004.06.023, PII S0195670104002695
    • A. Pajkos, K. Vickery, and E.Y. Cossart Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and contamination? J Hosp Infect 58 2004 224 229 (Pubitemid 39462591)
    • (2004) Journal of Hospital Infection , vol.58 , Issue.3 , pp. 224-229
    • Pajkos, A.1    Vickery, K.2    Cossart, Y.3
  • 9
    • 0035125447 scopus 로고    scopus 로고
    • Pitfalls in endoscope reprocessing: Brushing of air and water channels is mandatory for high-level disinfection
    • DOI 10.1067/mge.2001.112195
    • Y. Ishino, K. Ido, H. Koiwai, and K. Sugano Pitfalls in endoscope reprocessing: brushing of air and water channels is mandatory for high-level disinfection Gastrointest Endosc 53 2001 165 168 (Pubitemid 32147596)
    • (2001) Gastrointestinal Endoscopy , vol.53 , Issue.2 , pp. 165-168
    • Ishino, Y.1    Ido, K.2    Koiwai, H.3    Sugano, K.4
  • 10
    • 84870413386 scopus 로고    scopus 로고
    • Establishing a clinically relevant bioburden benchmark: A quality indicator for adequate reprocessing and storage of flexible gastrointestinal endoscopes
    • M.J. Alfa, S. Sepehri, N. Olson, and A.W. Diploma Establishing a clinically relevant bioburden benchmark: a quality indicator for adequate reprocessing and storage of flexible gastrointestinal endoscopes Am J Infect Control 17 2011 1451 1463
    • (2011) Am J Infect Control , vol.17 , pp. 1451-1463
    • Alfa, M.J.1    Sepehri, S.2    Olson, N.3    Diploma, A.W.4
  • 11
    • 0032746590 scopus 로고    scopus 로고
    • Quantitative determination of endotoxins released by bacterial biofilms
    • C. Riouful, C. Devys, G. Meunier, M. Perraud, and D. Goullet Quantitative determination of endotoxins released by bacterial biofilms J Hosp Infect 43 1999 203 209
    • (1999) J Hosp Infect , vol.43 , pp. 203-209
    • Riouful, C.1    Devys, C.2    Meunier, G.3    Perraud, M.4    Goullet, D.5
  • 12
    • 34548040745 scopus 로고    scopus 로고
    • Reprocessing flexible gastrointestinal endoscopes after a period of disuse: Is it necessary?
    • DOI 10.1055/s-2007-966644
    • A.S. Vergis, D. Thomson, P. Pieroni, and S. Dhalla Reprocessing flexible gastrointestinal endoscopes after a period of disuse: is it necessary? Endoscopy 39 2007 737 739 (Pubitemid 47299943)
    • (2007) Endoscopy , vol.39 , Issue.8 , pp. 737-739
    • Vergis, A.S.1    Thomson, D.2    Pieroni, P.3    Dhalla, S.4
  • 13
    • 34147134901 scopus 로고    scopus 로고
    • Microbiologic profile of flexible endoscope disinfection in two Brazilian hospitals
    • DOI 10.1590/S0004-28032006000400002
    • A.P. Machado, A.T.M. Pimenta, P.P. Contijo, S. Geocze, and O. Fischman Microbiologic profile of flexible endoscope disinfection in two Brazilian hospitals Arq Gastroenterol 43 2006 255 258 (Pubitemid 46556121)
    • (2006) Arquivos de Gastroenterologia , vol.43 , Issue.4 , pp. 255-258
    • Machado, A.P.1    Pimenta, A.T.M.2    Contijo, P.P.3    Geocze, S.4    Fischman, O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.