메뉴 건너뛰기




Volumn 28, Issue 6, 2012, Pages 1299-1304

Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography

Author keywords

Image compensation; Motion artifacts; OCT; OFDI

Indexed keywords

ACCURACY; ARTICLE; ARTIFACT; CARDIAC IMAGING; CORONARY HEMODYNAMICS; COST EFFECTIVENESS ANALYSIS; HEAD MOVEMENT; HEART CATHETER; IMAGE ANALYSIS; IMAGE QUALITY; INTRACORONARY OPTICAL FREQUENCY DOMAIN IMAGING; LIGHT SCATTERING; OPTICAL COHERENCE TOMOGRAPHY; QUANTITATIVE ANALYSIS; SEMICONDUCTOR; THREE DIMENSIONAL IMAGING;

EID: 84870466613     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-011-9953-8     Document Type: Article
Times cited : (10)

References (9)
  • 4
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    • Choma MA, Sarunic MV, Yang C, Izatt JA (2003) Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Opt Express 11:2183-2189
    • (2003) Opt Express , vol.11 , pp. 2183-2189
    • Choma, M.A.1    Sarunic, M.V.2    Yang, C.3    Izatt, J.A.4
  • 7
    • 76049118483 scopus 로고    scopus 로고
    • Advantage of next-generation frequencydomain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion
    • Takarada S, Imanishi T, Liu Y, Ikejima H, Tsujioka H, Kuroi A et al (2010) Advantage of next-generation frequencydomain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion. Catheter Cardiovasc Interv 75:202-206
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 202-206
    • Takarada, S.1    Imanishi, T.2    Liu, Y.3    Ikejima, H.4    Tsujioka, H.5    Kuroi, A.6
  • 8
    • 77952867434 scopus 로고    scopus 로고
    • A case of lipid core plaque progression and rupture at the edge of a coronary stent: Elucidating the mechanisms of des failure
    • Waxman S, Freilich MI, Suter MJ, Shishkov M, Bilazarian S, Virmani R et al (2010) A case of lipid core plaque progression and rupture at the edge of a coronary stent: elucidating the mechanisms of DES failure. Circ Cardiovasc Interv 3:193-196
    • (2010) Circ Cardiovasc Interv , vol.3 , pp. 193-196
    • Waxman, S.1    Freilich, M.I.2    Suter, M.J.3    Shishkov, M.4    Bilazarian, S.5    Virmani, R.6
  • 9
    • 77952815331 scopus 로고    scopus 로고
    • Compensation of motion artifacts in catheter-based optical frequency domain imaging
    • Ha JY, Shishkov M, Colice M, Oh WY, Yoo H, Liu L et al (2010) Compensation of motion artifacts in catheter-based optical frequency domain imaging. Opt Express 18:11418-11427
    • (2010) Opt Express , vol.18 , pp. 11418-11427
    • Ha, J.Y.1    Shishkov, M.2    Colice, M.3    Oh, W.Y.4    Yoo, H.5    Liu, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.