메뉴 건너뛰기




Volumn 7, Issue 11, 2012, Pages

LAMBDA - Large area medipix3-based detector array

Author keywords

Data acquisition circuits; Hybrid detectors; Solid state detectors; X ray detectors

Indexed keywords

10-GIGABIT ETHERNET; DATA ACQUISITION CIRCUIT; DETECTOR ARRAYS; HIGH FRAME RATE; HYBRID DETECTORS; SOLID STATE DETECTORS; X-RAY DETECTIONS; X-RAY DETECTOR;

EID: 84870262444     PISSN: None     EISSN: 17480221     Source Type: Journal    
DOI: 10.1088/1748-0221/7/11/C11009     Document Type: Conference Paper
Times cited : (35)

References (5)
  • 1
    • 65549127796 scopus 로고    scopus 로고
    • Performance of single-photon-counting PILATUS detector modules
    • 10.1107/S0909049509009911 0909-0495
    • P. Kraft et al. 2009 Performance of single-photon-counting PILATUS detector modules, J. Synchrotron Radiat. 16 368
    • (2009) J. Synchrotron Radiat. , vol.16 , pp. 368
    • Kraft, P.1
  • 2
    • 0036815755 scopus 로고    scopus 로고
    • Medipix2: A 64-k pixel readout chip with 55-μm square elements working in single photon counting mode
    • DOI 10.1109/TNS.2002.803788
    • X. Llopart, M. Campbell, R. Dinapoli, D. San Segundo and E. Pernigotti 2002 Medipix2: a 64-k pixel readout chip with 55-μm square elements working in single photon counting mode, IEEE Trans. Nucl. Sci. 49 2279 (Pubitemid 35443088)
    • (2002) IEEE Transactions on Nuclear Science , vol.49 , Issue.5 , pp. 2279-2283
    • Llopart, X.1    Campbell, M.2    Dinapoli, R.3    San Segundo, D.4    Pernigotti, E.5
  • 3
    • 79959823582 scopus 로고    scopus 로고
    • Medipix3: A 64-k pixel detector readout chip working in single photon counting mode with improved spectrometric performance
    • 10.1016/j.nima.2010.06.108 0168-9002
    • R. Ballabriga et al. 2011 Medipix3: a 64-k pixel detector readout chip working in single photon counting mode with improved spectrometric performance, Nucl. Instrum. Meth. A 633 S15
    • (2011) Nucl. Instrum. Meth. A , vol.633
    • Ballabriga, R.1
  • 4
    • 80053542356 scopus 로고    scopus 로고
    • Simulated performance of high-Z detectors with Medipix3 readout
    • 1748-0221
    • D. Pennicard and H. Graafsma 2011 Simulated performance of high-Z detectors with Medipix3 readout, JINST 6 P06007
    • (2011) JINST , vol.6 , Issue.6
    • Pennicard, D.1    Graafsma, H.2
  • 5
    • 82955201721 scopus 로고    scopus 로고
    • Development of LAMBDA: Large Area Medipix-Based Detector Array
    • 1748-0221
    • D. Pennicard et al. 2011 Development of LAMBDA: Large Area Medipix-Based Detector Array, JINST 6 C11009
    • (2011) JINST , vol.6 , Issue.11
    • Pennicard, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.