메뉴 건너뛰기




Volumn 34, Issue 1-2, 2013, Pages 173-182

Detection of a static eccentricity fault in a closed loop driven induction motor by using the angular domain order tracking analysis method

Author keywords

Eccentricity; Fault diagnosis; Induction motors; Order tracking analysis; Transient analysis

Indexed keywords

ADDITIONAL COSTS; ANGULAR DOMAIN; CLOSED LOOPS; DRIVEN SYSTEM; DYNAMIC VIBRATION; ECCENTRICITY; EXPERIMENTAL STUDIES; FAULT DIAGNOSIS METHOD; FREQUENCY SPECTRA; LOAD LEVELS; LOCATION OF FAULT; MOTOR CURRENTS; MOTOR PHASE; ORDER TRACKING; ORDER TRACKING ANALYSIS; ROTATING MACHINE; ROTOR SPEED; SPEED SENSORS; STATIC ECCENTRICITIES; VECTOR CONTROLS;

EID: 84870246782     PISSN: 08883270     EISSN: 10961216     Source Type: Journal    
DOI: 10.1016/j.ymssp.2012.04.003     Document Type: Article
Times cited : (47)

References (23)
  • 2
    • 0033705152 scopus 로고    scopus 로고
    • Determination of air-gap eccentricity in electric motors using coherence analysis
    • S. Seker Determination of air-gap eccentricity in electric motors using coherence analysis IEEE Power Eng. Rev. 20 2000 48 50
    • (2000) IEEE Power Eng. Rev. , vol.20 , pp. 48-50
    • Seker, S.1
  • 3
    • 0242540507 scopus 로고    scopus 로고
    • A reliability model for induction motor ball bearing degradation
    • S. Seker, and E. Ayaz A reliability model for induction motor ball bearing degradation Electr. Power Components Syst. 31 2003 639 652
    • (2003) Electr. Power Components Syst. , vol.31 , pp. 639-652
    • Seker, S.1    Ayaz, E.2
  • 5
    • 67649563244 scopus 로고    scopus 로고
    • Fault detection based on continuous wavelet transform and sensor fusion in electric motors
    • E. Ayaz, S. Seker, A. Ozturk, and B.R. Upadhyaya Fault detection based on continuous wavelet transform and sensor fusion in electric motors Compel 28 2 2009 454 470
    • (2009) Compel , vol.28 , Issue.2 , pp. 454-470
    • Ayaz, E.1    Seker, S.2    Ozturk, A.3    Upadhyaya, B.R.4
  • 6
    • 29244467991 scopus 로고    scopus 로고
    • Condition monitoring and fault diagnosis of electrical motors - A review
    • DOI 10.1109/TEC.2005.847955
    • S. Nandi, H.A. Toliyat, and X. Li Condition monitoring and fault diagnosis of electrical motors - a review IEEE Trans. Energy Convers. 20 4 2005 719 729 (Pubitemid 41830047)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.4 , pp. 719-729
    • Nandi, S.1    Toliyat, H.A.2    Li, X.3
  • 7
    • 0038179392 scopus 로고    scopus 로고
    • Feature extraction related to bearing damage in electric motors by wavelet Analysis
    • S. Seker, and E. Ayaz Feature extraction related to bearing damage in electric motors by wavelet Analysis J. Franklin Inst. 340 2003 125 134
    • (2003) J. Franklin Inst. , vol.340 , pp. 125-134
    • Seker, S.1    Ayaz, E.2
  • 13
    • 34547126685 scopus 로고    scopus 로고
    • Detection of rotor eccentricity faults in a closed-loop drive-connected induction motor using an artificial neural network
    • DOI 10.1109/TPEL.2007.900607
    • X. Huang, T.G. Habetler, and R.G. Harley Detection of rotor eccentricity faults in a closed-loop drive-connected induction motor using an artificial neural network IEEE Trans. Power Elect. 22 2007 1552 1559 (Pubitemid 47098857)
    • (2007) IEEE Transactions on Power Electronics , vol.22 , Issue.4 , pp. 1552-1559
    • Huang, X.1    Habetler, T.G.2    Harley, R.G.3
  • 14
  • 15
    • 67651036195 scopus 로고    scopus 로고
    • Hilbert versus Concordia transform for three-phase machine stator current time-frequency monitoring
    • B. Trajin, M. Chabert, J. Regnier, and J. Faucher Hilbert versus Concordia transform for three-phase machine stator current time-frequency monitoring Mech. Syst. Signal Process. 23 2009 2648 2657
    • (2009) Mech. Syst. Signal Process. , vol.23 , pp. 2648-2657
    • Trajin, B.1    Chabert, M.2    Regnier, J.3    Faucher, J.4
  • 16
    • 78649389423 scopus 로고    scopus 로고
    • Detection of static eccentricity for permanent magnet synchronous motors using the coherence analysis
    • M. Akar, S. Taskn, S. Seker, and I. Cankaya Detection of static eccentricity for permanent magnet synchronous motors using the coherence analysis Turk. J. Electr. Eng. Comput. Sci. 18 2010 963 974
    • (2010) Turk. J. Electr. Eng. Comput. Sci. , vol.18 , pp. 963-974
    • Akar, M.1    Taskn, S.2    Seker, S.3    Cankaya, I.4
  • 17
    • 3242886318 scopus 로고    scopus 로고
    • Detection of mechanical imbalances of induction machines without spectral analysis of time-domain signals
    • C. Kral, T.G. Habetler, and R.G. Harley Detection of mechanical imbalances of induction machines without spectral analysis of time-domain signals IEEE Trans. Ind. Appl. 40 2004 1101 1106
    • (2004) IEEE Trans. Ind. Appl. , vol.40 , pp. 1101-1106
    • Kral, C.1    Habetler, T.G.2    Harley, R.G.3
  • 20
    • 0041379262 scopus 로고    scopus 로고
    • Development and analysis of time variant discrete fourier transform order tracking
    • J.R. Blough Development and analysis of time variant discrete fourier transform order tracking Mech. Syst. Signal Process. 17 2003 1185 1199
    • (2003) Mech. Syst. Signal Process. , vol.17 , pp. 1185-1199
    • Blough, J.R.1
  • 22


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.