메뉴 건너뛰기




Volumn 31, Issue 12, 2012, Pages 1504-1506

First report of traumatic globe rupture after femtosecond laser-assisted penetrating keratoplasty

Author keywords

femtosecond lasera assisted penetrating keratoplasty; ruptured globe; wound dehiscence

Indexed keywords

ADULT; APHAKIA; ARTICLE; ASTIGMATISM; BLUNT TRAUMA; CASE REPORT; CATARACT; CORNEA DISEASE; CORNEA INJURY; CORNEA LACERATION; CORNEAL WOUND DEHISCENCE; FEMTOSECOND LASER; FEMTOSECOND LASER ASSISTED PENETRATING KERATOPLASTY; HISPANIC; HUMAN; LENS IMPLANT; LENSECTOMY; MALE; NYLON SUTURE; PENETRATING KERATOPLASTY; POSTERIOR CHAMBER LENS; PRIORITY JOURNAL; SCAR; SCLERA; SURGICAL RISK; SURGICAL TECHNIQUE; SUTURING METHOD; UVEA; VISUAL ACUITY; WOUND DEHISCENCE; WOUND HEALING;

EID: 84870239893     PISSN: 02773740     EISSN: 15364798     Source Type: Journal    
DOI: 10.1097/ICO.0b013e31824a6f47     Document Type: Article
Times cited : (3)

References (6)
  • 1
    • 34247173650 scopus 로고    scopus 로고
    • The use of the femtosecond laser in penetrating keratoplasty
    • Buratto L, Böhm E. The use of the femtosecond laser in penetrating keratoplasty. Am J Ophthalmol. 2007;143:737-742.
    • (2007) Am J Ophthalmol. , vol.143 , pp. 737-742
    • Buratto, L.1    Böhm, E.2
  • 2
    • 79952280177 scopus 로고    scopus 로고
    • Comparison of femtosecond laser-assisted keratoplasty versus conventional penetrating keratoplasty
    • Chamberlain WD, Rush SW, Mathers WD, et al. Comparison of femtosecond laser-assisted keratoplasty versus conventional penetrating keratoplasty. Ophthalmology. 2011;118:486-491.
    • (2011) Ophthalmology , vol.118 , pp. 486-491
    • Chamberlain, W.D.1    Rush, S.W.2    Mathers, W.D.3
  • 3
    • 69249205431 scopus 로고    scopus 로고
    • Comparison of penetrating keratoplasty performed with a femtosecond laser zig-zag incision versus conventional blade trephination
    • Farid M, Steinert RF, Gaster RN, et al. Comparison of penetrating keratoplasty performed with a femtosecond laser zig-zag incision versus conventional blade trephination. Ophthalmology. 2009;116:1638-1643.
    • (2009) Ophthalmology , vol.116 , pp. 1638-1643
    • Farid, M.1    Steinert, R.F.2    Gaster, R.N.3
  • 4
    • 33646010959 scopus 로고    scopus 로고
    • Top hat wound configuration for penetrating keratoplasty using the femtosecond laser: A laboratory model
    • Ignacio TS, Nguyen TB, Chuck RS, et al. Top hat wound configuration for penetrating keratoplasty using the femtosecond laser: a laboratory model. Cornea. 2006;25:336-340.
    • (2006) Cornea. , vol.25 , pp. 336-340
    • Ignacio, T.S.1    Nguyen, T.B.2    Chuck, R.S.3
  • 5
  • 6
    • 70350569299 scopus 로고    scopus 로고
    • Characteristics of traumatic globe rupture after keratoplasty
    • Kawashima M, Kawakita T, Shimmura S, et al. Characteristics of traumatic globe rupture after keratoplasty. Ophthalmology. 2009;116:2072-2076.
    • (2009) Ophthalmology , vol.116 , pp. 2072-2076
    • Kawashima, M.1    Kawakita, T.2    Shimmura, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.