Volumn , Issue , 2011, Pages 2080-2087

Comfort and building performance analysis of transparent building integrated silicon photovoltaics

Author keywords

[No Author keywords available]

Indexed keywords

ADOPTED TECHNOLOGY; AREA RATIOS; BUILDING INTEGRATED PHOTOVOLTAIC; BUILDING PERFORMANCE; COMFORT ANALYSIS; COOLING ENERGY; DAYLIGHT FACTORS; ENERGY GENERATIONS; ENERGY PERFORMANCE; MONOCRYSTALLINE; MULTICRYSTALLINE CELLS; PHOTOVOLTAICS; REFERENCE SYSTEMS; SHADING SYSTEMS; THERMAL SIMULATIONS; VENETIAN BLIND; VISUAL COMFORT; VISUAL CONTACTS;

EID: 84870220855     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (18)
  • 5
    • 84855440065 scopus 로고    scopus 로고
    • Directive 2010/31/EU on the energy performance of buildings (EPBD Recast)
    • European Parliament
    • European Parliament, Directive 2010/31/EU on the energy performance of buildings (EPBD Recast), Official Journal of the European Union, L153, (2010), 13-35
    • (2010) Official Journal of the European Union , vol.153 L. , pp. 13-35
  • 9
    • 78049485832 scopus 로고    scopus 로고
    • Solar control: A general method for modelling of solar gains through complex facades in building simulation programs
    • Kuhn T.E., et al., Solar control: A general method for modelling of solar gains through complex facades in building simulation programs, Energy and Buildings, 43 (1), (2011), 19-27
    • (2011) Energy and Buildings , vol.43 , Issue.1 , pp. 19-27
    • Kuhn, T.E.1
  • 10
    • 33645416089 scopus 로고    scopus 로고
    • Solar control: A general evaluation method for facades with venetian blinds or other solar control systems
    • Kuhn T.E., Solar control: A general evaluation method for facades with venetian blinds or other solar control systems, Energy and buildings 38 (6), (2006), 648-660
    • (2006) Energy and Buildings , vol.38 , Issue.6 , pp. 648-660
    • Kuhn, T.E.1
  • 11
    • 84871002684 scopus 로고    scopus 로고
    • Meteonorm, Meteotest
    • Meteonorm, Meteotest, www.meteonorm.com, (2011)
    • (2011)
  • 12
    • 84861026259 scopus 로고    scopus 로고
    • Simulation of irradiation and temperature dependent efficiency of thin film and crystalline silicon modules
    • Valencia
    • Müller B., et al., Simulation of irradiation and temperature dependent efficiency of thin film and crystalline silicon modules, 25th European PV Solar Energy Conference and Exhibition, (2010), Valencia
    • (2010) 25th European PV Solar Energy Conference and Exhibition
    • Müller, B.1
  • 13
    • 0035451348 scopus 로고    scopus 로고
    • Validation of dynamic RADIANCE-based daylight simulations for a test office with external blinds
    • Reinhart C.F. and Walkenhorst O., Validation of dynamic RADIANCE-based daylight simulations for a test office with external blinds. Energy & Buildings, 33(7), (2001), 683-697.
    • (2001) Energy & Buildings , vol.33 , Issue.7 , pp. 683-697
    • Reinhart, C.F.1    Walkenhorst, O.2
  • 14
    • 0042023450 scopus 로고    scopus 로고
    • Monitoring Manual Control of Electric Lighting and Blinds
    • Reinhart C. F., Voss K., Monitoring Manual Control of Electric Lighting and Blinds, Lighting Research and Technology, 35(3), (2003), 243-258
    • (2003) Lighting Research and Technology , vol.35 , Issue.3 , pp. 243-258
    • Reinhart, C.F.1    Voss, K.2
  • 15
    • 84870197192 scopus 로고    scopus 로고
    • Design methodology for optimization of electricity generation and daylight utilization for façade with semitransparent photovoltaics
    • Robinson L., Athienitis A., Design methodology for optimization of electricity generation and daylight utilization for façade with semitransparent photovoltaics, Eleventh International IBPSA Conference Building Simulation, (2009)
    • (2009) Eleventh International IBPSA Conference Building Simulation
    • Robinson, L.1    Athienitis, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.