-
1
-
-
33845394645
-
Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems
-
DOI 10.1097/01.blo.0000238875.86519.cf, PII 0000308620061200000035
-
Garbuz DS, Toms A, Masri BA, Duncan CP. Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems. Clin Orthop Relat Res 2006;453:199-202. (Pubitemid 44900984)
-
(2006)
Clinical Orthopaedics and Related Research
, Issue.453
, pp. 199-202
-
-
Garbuz, D.S.1
Toms, A.2
Masri, B.A.3
Duncan, C.P.4
-
3
-
-
0242496342
-
Classification and an algorithmic approach to the reconstruction of femoral deficiency in revision total hip arthroplasty
-
Valle CJ, Paprosky WG. Classification and an algorithmic approach to the reconstruction of femoral deficiency in revision total hip arthroplasty. J Bone Joint Surg [Am] 2003;85-A(suppl 4):1-6. (Pubitemid 37377422)
-
(2003)
Journal of Bone and Joint Surgery - Series A
, vol.85
, Issue.SUPPL. 4
, pp. 1-6
-
-
Della, V.C.J.1
Paprosky, W.G.2
-
4
-
-
9644268065
-
Femoral fixation in the face of considerable bone loss: The use of modular stems
-
DOI 10.1097/01.blo.0000150120.80409.0d
-
Sporer SM, Paprosky WG. Femoral fixation in the face of considerable bone loss: the use of modular stems. Clin Orthop Relat Res 2004;429:227-231. (Pubitemid 39579217)
-
(2004)
Clinical Orthopaedics and Related Research
, Issue.429
, pp. 227-231
-
-
Sporer, S.M.1
Paprosky, W.G.2
-
5
-
-
0025179416
-
Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
-
Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 1990;257:107-128. (Pubitemid 20246731)
-
(1990)
Clinical Orthopaedics and Related Research
, Issue.257
, pp. 107-128
-
-
Engh, C.A.1
Massin, P.2
Suthers, K.E.3
-
6
-
-
0034924526
-
Femoral revision with the Wagner SL revision stem: Evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years
-
Böhm P, Bischel O. Femoral revision with the Wagner SL revision stem: evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years. J Bone Joint Surg [Am] 2001;83-A:1023-1031. (Pubitemid 32662104)
-
(2001)
Journal of Bone and Joint Surgery - Series A
, vol.83
, Issue.7
, pp. 1023-1031
-
-
Bohm, P.1
Bischel, O.2
-
7
-
-
85172043051
-
Mid to long term follow-up of femoral revision arthroplasty with tapered fluted modular titanium stems in patients with severe proximal femoral bone defects
-
article in press.
-
Van Houwelingen AP, Duncan CP, Masri BA, Greidanus NV, Garbuz DS. Mid to long term follow-up of femoral revision arthroplasty with tapered fluted modular titanium stems in patients with severe proximal femoral bone defects. Clin Orthop Relat Res 2012; article in press.
-
(2012)
Clin Orthop Relat Res
-
-
Van Houwelingen, A.P.1
Duncan, C.P.2
Masri, B.A.3
Greidanus, N.V.4
Garbuz, D.S.5
|