메뉴 건너뛰기




Volumn 39, Issue 5, 2012, Pages 635-638

Extremely high-pressure dilation with a new imoncompliant balloon

Author keywords

Angioplasty, balloon, coronary instrumentation methods; Balloon dilation; Calcinosis therapy; Compliance; Coronary stenosis therapy; Prosthesis failure; Stents

Indexed keywords

AGED; ANGINA PECTORIS; ANGIOGRAPHY; ARTICLE; BALLOON; BALLOON DILATATION; CASE REPORT; CATHETER; DRUG ELUTING STENT; FEMALE; HUMAN; NONCOMPLIANT HIGH PRESSURE BALLOON; PERCUTANEOUS CORONARY INTERVENTION; TREATMENT OUTCOME;

EID: 84870168269     PISSN: 07302347     EISSN: 15266702     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (29)

References (12)
  • 1
    • 79251488492 scopus 로고    scopus 로고
    • Undefeatable coronary lesion [published erratum appears in J Pak Med Assoc 2011;61(4):424]
    • Farman MT, Sial JA, Khan NU, Masood T, Saghir T. Undefeatable coronary lesion [published erratum appears in J Pak Med Assoc 2011;61(4): 424]. J Pak Med Assoc 2011;61(2):185-7.
    • (2011) J Pak Med Assoc , vol.61 , Issue.2 , pp. 185-187
    • Farman, M.T.1    Sial, J.A.2    Khan, N.U.3    Masood, T.4    Saghir, T.5
  • 6
    • 37649023401 scopus 로고    scopus 로고
    • Two "buddies" may be better than one: Use of two buddy wires to expand an underexpanded left main coronary stent
    • Lindsey JB, Banerjee S, Brilakis ES. Two "buddies" may be better than one: use of two buddy wires to expand an underexpanded left main coronary stent. J Invasive Cardiol 2007;19(12):E355-8.
    • (2007) J Invasive Cardiol , vol.19 , Issue.12
    • Lindsey, J.B.1    Banerjee, S.2    Brilakis, E.S.3
  • 7
    • 77952787784 scopus 로고    scopus 로고
    • A noncompliant, high pressure balloon to manage undilatable coronary lesions
    • Raja Y, Routledge HC, Doshi SN. A noncompliant, high pressure balloon to manage undilatable coronary lesions. Catheter Cardiovasc Interv 2010;75(7):1067-73.
    • (2010) Catheter Cardiovasc Interv , vol.75 , Issue.7 , pp. 1067-1073
    • Raja, Y.1    Routledge, H.C.2    Doshi, S.N.3
  • 8
    • 0013485213 scopus 로고
    • Intravascular ultrasound guided rotational atherectomy of fibro-calcific plaque prior to intracoronary deployment of Palmaz-Schatz stents [abstract]
    • Goldberg SL, Hall P, Almagor Y, Maiello L, Finci L, Tobis J, Colombo A. Intravascular ultrasound guided rotational atherectomy of fibro-calcific plaque prior to intracoronary deployment of Palmaz-Schatz stents [abstract]. J Am Coll Cardiol 1994;23(2 s1):290A.
    • (1994) J Am Coll Cardiol , vol.23 , Issue.2 S1
    • Goldberg, S.L.1    Hall, P.2    Almagor, Y.3    Maiello, L.4    Finci, L.5    Tobis, J.6    Colombo, A.7
  • 11
    • 37849044532 scopus 로고    scopus 로고
    • Intravascular ultrasound assessment of the novel AngioSculpt scoring balloon catheter for the treatment of complex coronary lesions
    • Fonseca A, Costa Jde R Jr, Abizaid A, Feres F, Abizaid AS, Costa R, et al. Intravascular ultrasound assessment of the novel AngioSculpt scoring balloon catheter for the treatment of complex coronary lesions. J Invasive Cardiol 2008;20(1):21-7.
    • (2008) J Invasive Cardiol , vol.20 , Issue.1 , pp. 21-27
    • Fonseca, A.1    Costa Jde Jr., R.2    Abizaid, A.3    Feres, F.4    Abizaid, A.S.5    Costa, R.6
  • 12
    • 0026045875 scopus 로고
    • Two hugging balloons at high pressures successfully dilate a lesion refractory to routine coronary angioplasty
    • Feld H, Valerio L, Shani J. Two hugging balloons at high pressures successfully dilate a lesion refractory to routine coronary angioplasty. Cathet Cardiovasc Diagn 1991;24(2):105-7.
    • (1991) Cathet Cardiovasc Diagn , vol.24 , Issue.2 , pp. 105-107
    • Feld, H.1    Valerio, L.2    Shani, J.3