메뉴 건너뛰기




Volumn , Issue , 2012, Pages 119-141

Digital EEG

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84870057135     PISSN: None     EISSN: None     Source Type: Book    
DOI: None     Document Type: Chapter
Times cited : (4)

References (50)
  • 1
    • 84971466715 scopus 로고
    • Uber das Elektrenkephalogramm des Menschen IV. (English translation by P. Gloor: On the Electroencephalogram of Man, Electroenceph Clin Neurophysiol 1969, Suppl 28).
    • Berger H. Uber das Elektrenkephalogramm des Menschen IV. (English translation by P. Gloor: On the Electroencephalogram of Man, Electroenceph Clin Neurophysiol 1969, Suppl 28). Arch Psychiat Nervenheil. 1929;97:6-26.
    • (1929) Arch Psychiat Nervenheil. , vol.97 , pp. 6-26
    • Berger, H.1
  • 2
    • 0029298777 scopus 로고
    • The ENIAC: first general-purpose electronic computer. 1981.
    • Burks AW, Burks AR. The ENIAC: first general-purpose electronic computer. 1981. MD Comput. 1995;12(3):206-212.
    • (1995) MD Comput. , vol.12 , Issue.3 , pp. 206-212
    • Burks, A.W.1    Burks, A.R.2
  • 4
    • 84968470212 scopus 로고
    • An algorithm for the machine calculation of complex Fourier series.
    • Cooley JW, Tukey JW. An algorithm for the machine calculation of complex Fourier series. Math Comput. 1965;19:297-301.
    • (1965) Math Comput. , vol.19 , pp. 297-301
    • Cooley, J.W.1    Tukey, J.W.2
  • 5
    • 84937366335 scopus 로고
    • Digital electroencephalographs.
    • Technology and equipment review. Digital electroencephalographs. J Clin Neurophysiol. 1993;10(3):378-392.
    • (1993) J Clin Neurophysiol. , vol.10 , Issue.3 , pp. 378-392
  • 6
    • 84861573419 scopus 로고    scopus 로고
    • [updated February 10, 2006]. Available from:
    • Guideline Five: Guidelines for Standard Electrode Position Nomenclature. American Clinical Neurophysiology Society; 2006 [updated February 10, 2006]. Available from: https://www.acns.org/.
    • (2006) American Clinical Neurophysiology Society
  • 7
    • 33746816542 scopus 로고    scopus 로고
    • Ambulatory EEG telemetry: how good is it?
    • Schomer DL. Ambulatory EEG telemetry: how good is it? J Clin Neurophysiol. 2006;23(4):294-305.
    • (2006) J Clin Neurophysiol. , vol.23 , Issue.4 , pp. 294-305
    • Schomer, D.L.1
  • 9
    • 84861573419 scopus 로고    scopus 로고
    • [updated Februray 10, 2006]. Available from:
    • Guideline Eight: Guidelines for Recording Clinical EEG on Digital Media. American Clinical Neurophysiology Society; 2006 [updated Februray 10, 2006]. Available from: https://www.acns.org/.
    • (2006) American Clinical Neurophysiology Society
  • 10
    • 13944259001 scopus 로고    scopus 로고
    • Full-band EEG (FbEEG): an emerging standard in electroencephalography.
    • Vanhatalo S, Voipio J, Kaila K. Full-band EEG (FbEEG): an emerging standard in electroencephalography. Clin Neurophysiol. 2005;116(1):1-8.
    • (2005) Clin Neurophysiol. , vol.116 , Issue.1 , pp. 1-8
    • Vanhatalo, S.1    Voipio, J.2    Kaila, K.3
  • 11
    • 0004266734 scopus 로고
    • 2nd ed. Cambridge, England: Cambridge University Press;
    • Horowitz P, Hill W. The Art of Electronics. 2nd ed. Cambridge, England: Cambridge University Press; 1989.
    • (1989) The Art of Electronics.
    • Horowitz, P.1    Hill, W.2
  • 12
    • 0032607889 scopus 로고    scopus 로고
    • IFCN standards for digital recording of clinical EEG. The International Federation of Clinical Neurophysiology.
    • Nuwer MR, Comi G, Emerson R, et al. IFCN standards for digital recording of clinical EEG. The International Federation of Clinical Neurophysiology. Electroencephalogr Clin Neurophysiol Suppl. 1999;52:11-14.
    • (1999) Electroencephalogr Clin Neurophysiol Suppl. , vol.52 , pp. 11-14
    • Nuwer, M.R.1    Comi, G.2    Emerson, R.3
  • 13
    • 0031938989 scopus 로고    scopus 로고
    • Computer-based electroencephalography: technical basics, basis for new applications, and potential pitfalls.
    • Blum DE. Computer-based electroencephalography: technical basics, basis for new applications, and potential pitfalls. Electroencephalogr Clin Neurophysiol. 1998;106(2):118-126.
    • (1998) Electroencephalogr Clin Neurophysiol. , vol.106 , Issue.2 , pp. 118-126
    • Blum, D.E.1
  • 15
    • 0041863311 scopus 로고    scopus 로고
    • Biomonitoring with wireless communications.
    • Budinger TF. Biomonitoring with wireless communications. Annu Rev Biomed Eng. 2003;5:383-412.
    • (2003) Annu Rev Biomed Eng. , vol.5 , pp. 383-412
    • Budinger, T.F.1
  • 16
    • 62449230872 scopus 로고    scopus 로고
    • Guideline twelve: guidelines for long-term monitoring for epilepsy. Am J Electroneurodiagnostic Technol. 2008;48(4):265-286.
    • (2008) Am J Electroneurodiagnostic Technol. , vol.48 , Issue.4 , pp. 265-286
  • 17
    • 0023171470 scopus 로고
    • Video recording during long-term EEG monitoring of epileptic patients.
    • Ives JR. Video recording during long-term EEG monitoring of epileptic patients. Adv Neurol. 1987;46:1-11.
    • (1987) Adv Neurol. , vol.46 , pp. 1-11
    • Ives, J.R.1
  • 18
    • 0035710285 scopus 로고    scopus 로고
    • Design and evolution of a system for long-term electroencephalographic and video monitoring of epilepsy patients.
    • Burgess RC. Design and evolution of a system for long-term electroencephalographic and video monitoring of epilepsy patients. Methods. 2001;25(2):231-248.
    • (2001) Methods. , vol.25 , Issue.2 , pp. 231-248
    • Burgess, R.C.1
  • 19
    • 0027763217 scopus 로고
    • Viewing speed and frequency resolution in digital EEG.
    • Risk WS. Viewing speed and frequency resolution in digital EEG. Electroencephalogr Clin Neurophysiol. 1993;87(6):347-353.
    • (1993) Electroencephalogr Clin Neurophysiol. , vol.87 , Issue.6 , pp. 347-353
    • Risk, W.S.1
  • 20
    • 0002349614 scopus 로고
    • Algorithm for computer control of a digital plotter.
    • Bresenham J. Algorithm for computer control of a digital plotter. IBM Systems J. 1965;4(1):25-30.
    • (1965) IBM Systems J. , vol.4 , Issue.1 , pp. 25-30
    • Bresenham, J.1
  • 21
    • 0642311126 scopus 로고    scopus 로고
    • Aliasing in the visual EEG: a potential pitfall of video display technology.
    • Epstein CM. Aliasing in the visual EEG: a potential pitfall of video display technology. Clin Neurophysiol. 2003;114(10): 1974-1976.
    • (2003) Clin Neurophysiol. , vol.114 , Issue.10 , pp. 1974-1976
    • Epstein, C.M.1
  • 22
    • 0031914285 scopus 로고    scopus 로고
    • The advantages of digital over analog recording techniques.
    • Swartz BE. The advantages of digital over analog recording techniques. Electroencephalogr Clin Neurophysiol. 1998;106(2): 113-117.
    • (1998) Electroencephalogr Clin Neurophysiol. , vol.106 , Issue.2 , pp. 113-117
    • Swartz, B.E.1
  • 23
    • 0032411318 scopus 로고    scopus 로고
    • Comparison of digital and conventional EEG interpretation.
    • Levy SR, Berg AT, Testa FM, et al. Comparison of digital and conventional EEG interpretation. J Clin Neurophysiol. 1998;15(6):476-480.
    • (1998) J Clin Neurophysiol. , vol.15 , Issue.6 , pp. 476-480
    • Levy, S.R.1    Berg, A.T.2    Testa, F.M.3
  • 24
    • 0028262478 scopus 로고
    • American Electroencephalographic Society.
    • Guideline fourteen: guidelines for recording clinical EEG on digital media. American Electroencephalographic Society. J Clin Neurophysiol. 1994;11(1):114-115.
    • (1994) J Clin Neurophysiol. , vol.11 , Issue.1 , pp. 114-115
  • 25
    • 0025782330 scopus 로고
    • Localization of epileptogenic foci using a simple reference-subtraction montage to document small interchannel time differences.
    • Jayakar P, Duchowny MS, Resnick TJ, et al. Localization of epileptogenic foci using a simple reference-subtraction montage to document small interchannel time differences. J Clin Neurophysiol. 1991;8(2):212-215.
    • (1991) J Clin Neurophysiol. , vol.8 , Issue.2 , pp. 212-215
    • Jayakar, P.1    Duchowny, M.S.2    Resnick, T.J.3
  • 26
    • 0027385410 scopus 로고
    • Inverting a Laplacian topography map.
    • Klein SA. Inverting a Laplacian topography map. Brain Topogr. 1993;6(1):79-82.
    • (1993) Brain Topogr. , vol.6 , Issue.1 , pp. 79-82
    • Klein, S.A.1
  • 28
    • 0030128465 scopus 로고    scopus 로고
    • Determining the initial states in forward-backward filtering.
    • Gustafsson F. Determining the initial states in forward-backward filtering. IEEE Trans Signal Process. 1996;44(4):988-992.
    • (1996) IEEE Trans Signal Process. , vol.44 , Issue.4 , pp. 988-992
    • Gustafsson, F.1
  • 30
    • 0026683069 scopus 로고
    • Digital filtering: background and tutorial for psychophysiologists.
    • Cook EW III, Miller GA. Digital filtering: background and tutorial for psychophysiologists. Psychophysiology. 1992;29(3):350-367.
    • (1992) Psychophysiology. , vol.29 , Issue.3 , pp. 350-367
    • Cook, E.W.1    Miller, G.A.2
  • 32
    • 84973837770 scopus 로고
    • Status of quantitative EEG (QEEG) in clinical practice, 1994.
    • Duffy FH, Hughes JR, Miranda F, et al. Status of quantitative EEG (QEEG) in clinical practice, 1994. Clin Electroencephalogr. 1994;25(4):VI-XXII.
    • (1994) Clin Electroencephalogr. , vol.25 , Issue.4 , pp. VI-XXII
    • Duffy, F.H.1    Hughes, J.R.2    Miranda, F.3
  • 33
    • 0032620948 scopus 로고    scopus 로고
    • IFCN guidelines for topographic and frequency analysis of EEGs and EPs. The International Federation of Clinical Neurophysiology.
    • Nuwer MR, Lehmann D, da Silva FL, et al. IFCN guidelines for topographic and frequency analysis of EEGs and EPs. The International Federation of Clinical Neurophysiology. Electroencephalogr Clin Neurophysiol Suppl. 1999;52:15-20.
    • (1999) Electroencephalogr Clin Neurophysiol Suppl. , vol.52 , pp. 15-20
    • Nuwer, M.R.1    Lehmann, D.2    da Silva, F.L.3
  • 34
    • 0032962246 scopus 로고    scopus 로고
    • Automatic detection of seizures and spikes.
    • Gotman J. Automatic detection of seizures and spikes. J Clin Neurophysiol. 1999;16(2):130-140.
    • (1999) J Clin Neurophysiol. , vol.16 , Issue.2 , pp. 130-140
    • Gotman, J.1
  • 35
    • 0029446252 scopus 로고
    • A seizure warning system for long-term epilepsy monitoring.
    • Qu H, Gotman J. A seizure warning system for long-term epilepsy monitoring. Neurology. 1995;45(12):2250-2254.
    • (1995) Neurology. , vol.45 , Issue.12 , pp. 2250-2254
    • Qu, H.1    Gotman, J.2
  • 36
    • 0032917263 scopus 로고    scopus 로고
    • Spike detection II: automatic, perception-based detection and clustering.
    • Wilson SB, Turner CA, Emerson RG, et al. Spike detection II: automatic, perception-based detection and clustering. Clin Neurophysiol. 1999;110(3):404-411.
    • (1999) Clin Neurophysiol. , vol.110 , Issue.3 , pp. 404-411
    • Wilson, S.B.1    Turner, C.A.2    Emerson, R.G.3
  • 37
    • 22844431998 scopus 로고    scopus 로고
    • A neural network method for automatic and incremental learning applied to patient-dependent seizure detection.
    • Wilson SB. A neural network method for automatic and incremental learning applied to patient-dependent seizure detection. Clin Neurophysiol. 2005;116(8):1785-1795.
    • (2005) Clin Neurophysiol. , vol.116 , Issue.8 , pp. 1785-1795
    • Wilson, S.B.1
  • 38
    • 0025155606 scopus 로고
    • The development of EEG brain mapping.
    • Nuwer MR. The development of EEG brain mapping. J Clin Neurophysiol. 1990;7(4):459-471.
    • (1990) J Clin Neurophysiol. , vol.7 , Issue.4 , pp. 459-471
    • Nuwer, M.R.1
  • 39
    • 0024578983 scopus 로고
    • Spherical splines for scalp potential and current density mapping.
    • Perrin F, Pernier J, Bertrand O, et al. Spherical splines for scalp potential and current density mapping. Electroencephalogr Clin Neurophysiol. 1989;72(2):184-187.
    • (1989) Electroencephalogr Clin Neurophysiol. , vol.72 , Issue.2 , pp. 184-187
    • Perrin, F.1    Pernier, J.2    Bertrand, O.3
  • 40
    • 0027448968 scopus 로고
    • Systematic comparisons of interpolation techniques in topographic brain mapping.
    • Soong AC, Lind JC, Shaw GR, et al. Systematic comparisons of interpolation techniques in topographic brain mapping. Electroencephalogr Clin Neurophysiol. 1993;87(4):185-195.
    • (1993) Electroencephalogr Clin Neurophysiol. , vol.87 , Issue.4 , pp. 185-195
    • Soong, A.C.1    Lind, J.C.2    Shaw, G.R.3
  • 41
    • 0026045935 scopus 로고
    • Spike voltage topography identifies two types of frontotemporal epileptic foci.
    • Ebersole JS, Wade PB. Spike voltage topography identifies two types of frontotemporal epileptic foci. Neurology. 1991;41(9):1425-1433.
    • (1991) Neurology. , vol.41 , Issue.9 , pp. 1425-1433
    • Ebersole, J.S.1    Wade, P.B.2
  • 42
    • 0346362441 scopus 로고    scopus 로고
    • Noninvasive methods for evaluating the localization and propagation of epileptic activity.
    • Gotman J. Noninvasive methods for evaluating the localization and propagation of epileptic activity. Epilepsia. 2003;44(suppl 12):21-29.
    • (2003) Epilepsia. , vol.44 , pp. 21-29
    • Gotman, J.1
  • 43
    • 0028091238 scopus 로고
    • Brain source imaging of focal and multifocal epileptiform EEG activity.
    • Scherg M, Ebersole JS. Brain source imaging of focal and multifocal epileptiform EEG activity. Neurophysiol Clin. 1994;24(1):51-60.
    • (1994) Neurophysiol Clin. , vol.24 , Issue.1 , pp. 51-60
    • Scherg, M.1    Ebersole, J.S.2
  • 44
    • 0029050516 scopus 로고
    • Power spectrum and intracranial EEG patterns at seizure onset in partial epilepsy.
    • Alarcon G, Binnie CD, Elwes RD, et al. Power spectrum and intracranial EEG patterns at seizure onset in partial epilepsy. Electroencephalogr Clin Neurophysiol. 1995;94(5):326-337.
    • (1995) Electroencephalogr Clin Neurophysiol. , vol.94 , Issue.5 , pp. 326-337
    • Alarcon, G.1    Binnie, C.D.2    Elwes, R.D.3
  • 45
    • 10344247133 scopus 로고    scopus 로고
    • Data analysis for continuous EEG monitoring in the ICU: seeing the forest and the trees.
    • Scheuer ML, Wilson SB. Data analysis for continuous EEG monitoring in the ICU: seeing the forest and the trees. J Clin Neurophysiol. 2004;21(5):353-378.
    • (2004) J Clin Neurophysiol. , vol.21 , Issue.5 , pp. 353-378
    • Scheuer, M.L.1    Wilson, S.B.2
  • 46
    • 33646717543 scopus 로고    scopus 로고
    • NPSG data interchange-dealing with the Tower of Babel.
    • Rapoport DM, Ayappa I, Norman RG, et al. NPSG data interchange-dealing with the Tower of Babel. Sleep. 2006;29(5):599-600.
    • (2006) Sleep. , vol.29 , Issue.5 , pp. 599-600
    • Rapoport, D.M.1    Ayappa, I.2    Norman, R.G.3
  • 47
    • 0042425970 scopus 로고    scopus 로고
    • European data format 'plus' (EDF+), an EDF alike standard format for the exchange of physiological data.
    • Kemp B, Olivan J. European data format 'plus' (EDF+), an EDF alike standard format for the exchange of physiological data. Clin Neurophysiol. 2003;114(9):1755-1761.
    • (2003) Clin Neurophysiol. , vol.114 , Issue.9 , pp. 1755-1761
    • Kemp, B.1    Olivan, J.2
  • 48
    • 0030265765 scopus 로고    scopus 로고
    • Extensible biosignal (EBS) file format: simple method for EEG data exchange.
    • Hellmann G, Kuhn M, Prosch M, et al. Extensible biosignal (EBS) file format: simple method for EEG data exchange. Electroencephalogr Clin Neurophysiol. 1996;99(5):426-431.
    • (1996) Electroencephalogr Clin Neurophysiol. , vol.99 , Issue.5 , pp. 426-431
    • Hellmann, G.1    Kuhn, M.2    Prosch, M.3
  • 50
    • 84971466711 scopus 로고    scopus 로고
    • Guideline TS1: Standard for transferring digital neurophysiological data between independent computer systems. J Clin Neurophysiol. 2008.
    • (2008) J Clin Neurophysiol.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.