메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Response and protection of DFIG system under grid fault

Author keywords

DFIG; Rotor voltage; Stator flux; Voltage drop; Voltage recovery

Indexed keywords

CRITICAL TECHNOLOGIES; DOUBLY-FED INDUCTION GENERATOR; DYNAMIC BEHAVIORS; GRID DISTURBANCE; GRID FAULT; GRID VOLTAGE; LARGE WIND TURBINES; LOW-VOLTAGE RIDE-THROUGH; ROTOR VOLTAGE; STATOR FLUX; VOLTAGE DIP; VOLTAGE DROP; VOLTAGE RECOVERY; WAVE FORMS;

EID: 84870027072     PISSN: 21574839     EISSN: 21574847     Source Type: Conference Proceeding    
DOI: 10.1109/APPEEC.2010.5448355     Document Type: Conference Paper
Times cited : (14)

References (12)
  • 7
    • 35248822705 scopus 로고    scopus 로고
    • Fault ride-through performance of wind turbine with doubly fed induction generator
    • DOI 10.1109/ICIEA.2007.4318680, 4318680, ICIEA 2007: 2007 Second IEEE Conference on Industrial Electronics and Applications
    • Heping Zou, Hui Sun, Jiyan Zou. Fault ride-through performance of wind turbine with doubly fed induction generator. 2007 Second IEEE Conference on Industrial Electronics and Applications, 2007, 1607-1611. (Pubitemid 47566011)
    • (2007) ICIEA 2007: 2007 Second IEEE Conference on Industrial Electronics and Applications , pp. 1607-1611
    • Zou, H.1    Sun, H.2    Zou, J.3
  • 8
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • J
    • Xiang Dawei, Li Ran, Tavner P J,et al. Control of a doubly fed induction generator in a wind turbine during grid fault ride-through[J]. IEEE Trans Energy Conversion, 2006,9(21):652-662.
    • (2006) IEEE Trans Energy Conversion , vol.9 , Issue.21 , pp. 652-662
    • Dawei, X.1    Ran, L.2    Tavner, P.J.3
  • 10
    • 33846975121 scopus 로고    scopus 로고
    • Modeling and control of wind-urbine used DFIG under network fault conditions
    • C
    • He Yikang, Hu Jiabing, Zhao Rende. Modeling and control of wind-urbine used DFIG under network fault conditions [C]. ICEMS 2005, 2:986-991.
    • (2005) ICEMS , vol.2 , pp. 986-991
    • Yikang, H.1    Jiabing, H.2    Rende, Z.3
  • 11
    • 0038519499 scopus 로고    scopus 로고
    • Dynamic modeling of doubly fed induction generator wind turbines
    • J
    • J.B.Ekanayake, L.Holdsworth, X.G.Wu, er al. Dynamic modeling of doubly fed induction generator wind turbines[J]. IEEE Trans Power Electron. 2003,18(2):803-809.
    • (2003) IEEE Trans Power Electron , vol.18 , Issue.2 , pp. 803-809
    • Ekanayake, J.B.1    Holdsworth, L.2    Wu, X.G.3
  • 12
    • 34548274089 scopus 로고    scopus 로고
    • Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    • DOI 10.1109/TEC.2006.878241
    • J.Lopez, P.Sanchis, X.Roboam, et al.Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips[J]. IEEE Transaction on Energy Conversion. 2007,22(3): 709-717. (Pubitemid 47323587)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.3 , pp. 709-717
    • Lopez, J.1    Sanchis, P.2    Roboam, X.3    Marroyo, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.