메뉴 건너뛰기




Volumn 4, Issue 4, 2012, Pages 325-328

Delayed rupture of flexor pollicis longus after volar plating for a distal radius fracture

Author keywords

Delayed rupture; Distal radius fracture; Flexor pollicis longus; Volar plating

Indexed keywords

ADULT; ARTICLE; CASE REPORT; CAST APPLICATION; COMPRESSION PLATE; DEBRIDEMENT; EXERCISE; FEMALE; FLEXOR POLLICIS LONGUS MUSCLE; FLEXOR TENDON INJURY; HAND RADIOGRAPHY; HUMAN; OPEN REDUCTION; OSTEOSYNTHESIS; PHYSICAL EXAMINATION; POSTOPERATIVE PERIOD; RADIUS FRACTURE; SKELETAL MUSCLE; VOLAR PLATE FIXATION;

EID: 84870026554     PISSN: 2005291X     EISSN: 20054408     Source Type: Journal    
DOI: 10.4055/cios.2012.4.4.325     Document Type: Article
Times cited : (24)

References (10)
  • 1
    • 34248229716 scopus 로고    scopus 로고
    • Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    • Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21(5):316-22.
    • (2007) J Orthop Trauma , vol.21 , Issue.5 , pp. 316-322
    • Arora, R.1    Lutz, M.2    Hennerbichler, A.3    Krappinger, D.4    Espen, D.5    Gabl, M.6
  • 2
    • 0032451332 scopus 로고    scopus 로고
    • Prospective multi-center trial of a plate for dorsal fixation of distal radius fractures
    • Louis DS. Prospective multi-center trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg Am. 1998;23(2):353-4.
    • (1998) J Hand Surg Am , vol.23 , Issue.2 , pp. 353-354
    • Louis, D.S.1
  • 3
    • 0034068196 scopus 로고    scopus 로고
    • Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate: Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation
    • Schnur DP, Chang B. Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate: Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation. Ann Plast Surg. 2000;44(5):564-6.
    • (2000) Ann Plast Surg , vol.44 , Issue.5 , pp. 564-566
    • Schnur, D.P.1    Chang, B.2
  • 4
    • 0031951657 scopus 로고    scopus 로고
    • Rupture of flexor pollicis longus tendon: A complication of volar plating of the distal radius
    • Bell JS, Wollstein R, Citron ND. Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius. J Bone Joint Surg Br. 1998;80(2):225-6.
    • (1998) J Bone Joint Surg Br , vol.80 , Issue.2 , pp. 225-226
    • Bell, J.S.1    Wollstein, R.2    Citron, N.D.3
  • 5
    • 39149097204 scopus 로고    scopus 로고
    • Flexor tendon injuries following locked volar plating of distal radius fractures
    • Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am. 2008;33(2):164-7.
    • (2008) J Hand Surg Am , vol.33 , Issue.2 , pp. 164-167
    • Cross, A.W.1    Schmidt, C.C.2
  • 6
    • 40549098158 scopus 로고    scopus 로고
    • Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius
    • Duncan SF, Weiland AJ. Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius. Am J Orthop (Belle Mead NJ). 2007;36(12):669-70.
    • (2007) Am J Orthop (Belle Mead NJ) , vol.36 , Issue.12 , pp. 669-670
    • Duncan, S.F.1    Weiland, A.J.2
  • 7
    • 34548487815 scopus 로고    scopus 로고
    • Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: A case report
    • Klug RA, Press CM, Gonzalez MH. Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report. J Hand Surg Am. 2007;32(7):984-8.
    • (2007) J Hand Surg Am , vol.32 , Issue.7 , pp. 984-988
    • Klug, R.A.1    Press, C.M.2    Gonzalez, M.H.3
  • 8
    • 0032720912 scopus 로고    scopus 로고
    • Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius
    • Nunley JA, Rowan PR. Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surg Am. 1999;24(6):1279-80.
    • (1999) J Hand Surg Am , vol.24 , Issue.6 , pp. 1279-1280
    • Nunley, J.A.1    Rowan, P.R.2
  • 9
    • 36448985125 scopus 로고    scopus 로고
    • Delayed rupture of flexor pollicis longus tendon after volar plating of the distal radius
    • Koo SC, Ho ST. Delayed rupture of flexor pollicis longus tendon after volar plating of the distal radius. Hand Surg. 2006;11(1-2):67-70.
    • (2006) Hand Surg , vol.11 , Issue.1-2 , pp. 67-70
    • Koo, S.C.1    Ho, S.T.2
  • 10
    • 33646840103 scopus 로고    scopus 로고
    • Current concepts in volar fixed-angle fixation of unstable distal radius fractures
    • Orbay JL, Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res. 2006;445:58-67.
    • (2006) Clin Orthop Relat Res , vol.445 , pp. 58-67
    • Orbay, J.L.1    Touhami, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.