메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Comparison of transient stability between wind farm based on DFIG and traditional power plant in an actual grid

Author keywords

Antual grid; Double fed induction generation; Synchronous generator; Transient stability; Wind turbine generation

Indexed keywords

ANTUAL GRID; CONTROL MODES; CRITICAL CLEARING TIME; DOUBLE FED INDUCTION GENERATOR; DOUBLE-FED INDUCTION; HIGH WIND SPEED; LOW SPEED; POINT OF COMMON COUPLING; POWER FACTORS; RENEWABLE ENERGIES; STEADY STATE; TERMINAL VOLTAGES; TRANSIENT STABILITY; WIND ENERGY; WIND FARM; WIND POWER CAPACITY; WIND TURBINE GENERATORS; WIND-TURBINE GENERATION;

EID: 84870023357     PISSN: 21574839     EISSN: 21574847     Source Type: Conference Proceeding    
DOI: 10.1109/APPEEC.2010.5448528     Document Type: Conference Paper
Times cited : (13)

References (11)
  • 2
    • 44649158287 scopus 로고    scopus 로고
    • On the stability of power systems containing doubly fed induction generator-based generation
    • Sep.
    • Katherine Elkington, Valerijs Knazkins, Mehrdad Ghandhari, "On the stability of power systems containing doubly fed induction generator-based generation," Electric Power Systems Research, Volume 78, pp. 1477-1484, Sep. 2008
    • (2008) Electric Power Systems Research , vol.78 , pp. 1477-1484
    • Elkington, K.1    Knazkins, V.2    Ghandhari, M.3
  • 3
    • 33749029254 scopus 로고    scopus 로고
    • The Effect on Transient Stability of Large Scale Wind Farm to Power System
    • Aug.
    • Yongning.Chi, Weisheng.Wang, Yanhua.Liu, Huizhu Dai. "The Effect on Transient Stability of Large Scale Wind Farm to Power System," Automation of Electric Power Systems,Vol.30, pp. 10-14,Aug.2006
    • (2006) Automation of Electric Power Systems , vol.30 , pp. 10-14
    • Chi, Y.1    Wang, W.2    Liu, Y.3    Dai, H.4
  • 5
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation
    • May
    • R.Pena, J.C.Clare, G.M.Asher, "Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation," IEE Proc. Electric Power Applications, vol.143, pp.231-241, May 1996.
    • (1996) IEE Proc. Electric Power Applications , vol.143 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 6
    • 25844461808 scopus 로고    scopus 로고
    • Modeling and simulation of AC excited VSCF in wind power systems
    • Aug.
    • Songjiang Bian, Xiaomei lv, Huijie Xiang, Liangen Liu, Bing Liang, "Modeling and simulation of AC excited VSCF in wind power systems," Proceedings of the CSEE, vol.25, no.16, pp.57-62, Aug. 2005.
    • (2005) Proceedings of the CSEE , vol.25 , Issue.16 , pp. 57-62
    • Bian, S.1    Lv, X.2    Xiang, H.3    Liu, L.4    Liang, B.5
  • 9
    • 77951470448 scopus 로고    scopus 로고
    • Simulation and Comparison of Transient Stability of Power System including DFIGs Wind Farm Based on Detailed Model
    • Li Lin, Hongjing Hou, Wenxia Li, Sheng Jing, "Simulation and Comparison of Transient Stability of Power System including DFIGs Wind Farm Based on Detailed Model," in 1st International Conference on SUPERGEN
    • 1st International Conference on SUPERGEN
    • Lin, L.1    Hou, H.2    Li, W.3    Jing, S.4
  • 11
    • 35548929870 scopus 로고    scopus 로고
    • Aggregated dynamic model for wind farms with doubly fed induction generator wind turbines
    • January
    • Luis M. Fernandeza, Francisco Jurado, Jose Ramon Saenz. "Aggregated dynamic model for wind farms with doubly fed induction generator wind turbines," Renewable Energy, Volume 33, Issue 1, pp. 129-140, January 2008
    • (2008) Renewable Energy , vol.33 , Issue.1 , pp. 129-140
    • Fernandeza, L.M.1    Jurado, F.2    Saenz, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.