메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Experimental research on LVRT capability of DFIG WECS during grid voltage sags

Author keywords

Dc side damp circuit; Doubly fed induction generator; Low voltage ride through; Rotor active crowbar; Voltage sag generator; Wind energy conversion system

Indexed keywords

CONTROL STRATEGIES; DOUBLY-FED INDUCTION GENERATOR; DURATION TIME; EXPERIMENTAL RESEARCH; EXPERIMENTAL TEST; GRID VOLTAGE; LOW-VOLTAGE RIDE-THROUGH; RATED VOLTAGES; STEADY-STATE MODELS; TRANSIENT CURRENT; VOLTAGE SAGS; WIND ENERGY CONVERSION SYSTEM;

EID: 84870019927     PISSN: 21574839     EISSN: 21574847     Source Type: Conference Proceeding    
DOI: 10.1109/APPEEC.2010.5448151     Document Type: Conference Paper
Times cited : (7)

References (4)
  • 1
    • 20544446440 scopus 로고    scopus 로고
    • Doubly fed induction generator model for transient stability analysis
    • DOI 10.1109/TEC.2005.845523
    • Ledesma P., Usaola J., "Doubly fed induction generator model for transient stability analysis". IEEE Transactions on Energy Conversion,.2005, 20(2): 388-397. (Pubitemid 40843740)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.2 , pp. 388-397
    • Ledesma, P.1    Usaola, J.2
  • 2
    • 35048853522 scopus 로고    scopus 로고
    • Performance study of a doubly fed wind-power induction generator under network disturbances
    • DOI 10.1109/TEC.2005.853741
    • Seman S., Niiranen J., Kanerva S., et al, "Performance Study of a Doubly Fed Wind-Power Induction Generator Under Network Disturbances" IEEE Transactions on Energy Conversion, 2006, 21(4): 883-890. (Pubitemid 44824173)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.4 , pp. 883-890
    • Seman, S.1    Niiranen, J.2    Kanerva, S.3    Arkkio, A.4    Saitz, J.5
  • 3
    • 20544451598 scopus 로고    scopus 로고
    • Ride through of wind turbines with doubly-fed induction generator during a voltage dip
    • J. Morren, S. W. H. de Haan., "Ride through of wind turbines with doubly-fed induction generator during a voltage dip". IEEE Transactions on Energy Conversion, 2005, 20(2): 435-441.
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.2 , pp. 435-441
    • Morren, J.1    De Haan, S.W.H.2
  • 4
    • 8744250132 scopus 로고    scopus 로고
    • Voltage recovery of grid-connected wind turbines with DFIG after a short-circuit fault
    • Sun T., Chen Z., Blaabjerg F., "Voltage recovery of grid-connected wind turbines with DFIG after a short-circuit fault". PESC2004, Vol.3, Page(s): 1991-1997.
    • PESC2004 , vol.3 , pp. 1991-1997
    • Sun, T.1    Chen, Z.2    Blaabjerg, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.