메뉴 건너뛰기




Volumn 40 A, Issue 6, 2012, Pages 295-305

Uncertainty analysis for absorption and first-derivative electron paramagnetic resonance spectra

Author keywords

EPR; Integrated intensity; Line width; Uncertainty analysis

Indexed keywords


EID: 84869798747     PISSN: 15466086     EISSN: 15525023     Source Type: Journal    
DOI: 10.1002/cmr.a.21248     Document Type: Article
Times cited : (22)

References (14)
  • 4
    • 19944405163 scopus 로고    scopus 로고
    • Rapid-scan EPR with triangular scans and Fourier deconvolution to recover the slow-scan spectrum
    • Joshi JP, Ballard JR, Rinard GA, Quine RW, Eaton SS, Eaton GR. 2005 Rapid-scan EPR with triangular scans and Fourier deconvolution to recover the slow-scan spectrum. J Magn Reson 175: 44-51.
    • (2005) J Magn Reson , vol.175 , pp. 44-51
    • Joshi, J.P.1    Ballard, J.R.2    Rinard, G.A.3    Quine, R.W.4    Eaton, S.S.5    Eaton, G.R.6
  • 10
    • 49549154278 scopus 로고
    • Sensitivity enhancement of ESR spectra by integration
    • Posener DW. 1974 Sensitivity enhancement of ESR spectra by integration. J Magn Reson 14: 129-140.
    • (1974) J Magn Reson , vol.14 , pp. 129-140
    • Posener, D.W.1
  • 11
    • 27744432331 scopus 로고    scopus 로고
    • Evaluating the third and fourth derivatives of spectral data
    • Yeow YL, Azali S, Ow SY, Wong MCL, Leong Y-K. 2005. Evaluating the third and fourth derivatives of spectral data. Talanta 68: 156-164.
    • (2005) Talanta , vol.68 , pp. 156-164
    • Yeow, Y.L.1    Azali, S.2    Ow, S.Y.3    Wong, M.C.L.4    Leong, Y.-K.5
  • 12
    • 0012331258 scopus 로고
    • Pseudomodulation: a computer-based strategy for resolution enhancement
    • Hyde JS, Jesmanowicz A, Ratke JJ, Antholine WE. 1992 Pseudomodulation: a computer-based strategy for resolution enhancement. J Magn Reson 96: 1-13.
    • (1992) J Magn Reson , vol.96 , pp. 1-13
    • Hyde, J.S.1    Jesmanowicz, A.2    Ratke, J.J.3    Antholine, W.E.4
  • 14
    • 79953664131 scopus 로고    scopus 로고
    • Comparison of 250 MHz electron spin echo and continuous wave oxygen EPR imaging methods for in vivo applications
    • Epel B, Sundramoorthy SV, Barth ED, Mailer C, Halpern HJ. 2011 Comparison of 250 MHz electron spin echo and continuous wave oxygen EPR imaging methods for in vivo applications. Med Phys 38: 2045-2052.
    • (2011) Med Phys , vol.38 , pp. 2045-2052
    • Epel, B.1    Sundramoorthy, S.V.2    Barth, E.D.3    Mailer, C.4    Halpern, H.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.