메뉴 건너뛰기




Volumn 7, Issue 4, 2012, Pages 274-281

Augmented reality image guidance improves navigation for beating heart mitral valve repair

Author keywords

Augmented reality image guidance; Chordal reconstruction; Echocardiography; Mitral valve repair; Off pump beating heart surgery

Indexed keywords

ANATOMIC LANDMARK; ANIMAL EXPERIMENT; ARTICLE; AUGMENTED REALITY IMAGE GUIDANCE; CARDIAC IMAGING; CONTROLLED STUDY; HEART LEFT VENTRICLE; INTERMETHOD COMPARISON; LEARNING CURVE; MITRAL VALVE; MITRAL VALVE REPAIR; NONHUMAN; OFF PUMP SURGERY; PRIORITY JOURNAL; SURGEON; SURGICAL EQUIPMENT; SWINE; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; VIRTUAL REALITY;

EID: 84869755298     PISSN: 15569845     EISSN: 15590879     Source Type: Journal    
DOI: 10.1097/IMI.0b013e31827439ea     Document Type: Article
Times cited : (28)

References (23)
  • 2
    • 77149139785 scopus 로고    scopus 로고
    • Early surgery is recommended for mitral regurgitation
    • Enriquez-Sarano M, Sundt TM III. Early surgery is recommended for mitral regurgitation. Circulation. 2010;121:804-811.
    • (2010) Circulation , vol.121 , pp. 804-811
    • Enriquez-Sarano, M.1    Sundt Iii., T.M.2
  • 3
    • 77955969069 scopus 로고    scopus 로고
    • Degenerative mitral valve regurgitation: Best practice revolution
    • Adams DH, Rosenhek R, Falk V. Degenerative mitral valve regurgitation: best practice revolution. Eur Heart J. 2010;31:1958-1966.
    • (2010) Eur Heart J , vol.31 , pp. 1958-1966
    • Adams, D.H.1    Rosenhek, R.2    Falk, V.3
  • 5
    • 0031744908 scopus 로고    scopus 로고
    • Long-term results of mitral valve repair for myxomatous disease with and without chordal replacement with expanded polytetrafluoroethylene sutures
    • David TE, Omran A, Armstrong S, Sun Z, Ivanov J. Long-term results of mitral valve repair for myxomatous disease with and without chordal replacement with expanded polytetrafluoroethylene sutures. J Thorac Cardiovasc Surg. 1998;115:1279-1285.
    • (1998) J Thorac Cardiovasc Surg , vol.115 , pp. 1279-1285
    • David, T.E.1    Omran, A.2    Armstrong, S.3    Sun, Z.4    Ivanov, J.5
  • 6
    • 56249130032 scopus 로고    scopus 로고
    • How does the use of polytetrafluoroethylene neochordae for posterior mitral valve prolapse (loop technique) compare with leaflet resection? A prospective randomized trial
    • Falk V, Seeburger J, Czesla M, et al. How does the use of polytetrafluoroethylene neochordae for posterior mitral valve prolapse (loop technique) compare with leaflet resection? A prospective randomized trial. J Thorac Cardiovasc Surg. 2008;136:1205.
    • (2008) J Thorac Cardiovasc Surg , vol.136 , pp. 1205
    • Falk, V.1    Seeburger, J.2    Czesla, M.3
  • 7
    • 65649114058 scopus 로고    scopus 로고
    • Chordae replacement versus resection for repair of isolated posterior mitral leaflet prolapse: Á ègalité
    • Seeburger J, Falk V, Borger MA, et al. Chordae replacement versus resection for repair of isolated posterior mitral leaflet prolapse: á ègalité. Ann Thorac Surg. 2009;87:1715-1720.
    • (2009) Ann Thorac Surg , vol.87 , pp. 1715-1720
    • Seeburger, J.1    Falk, V.2    Borger, M.A.3
  • 8
    • 67651108977 scopus 로고    scopus 로고
    • Mitral valve hemodynamics after repair of acute posterior leaflet prolapse: Quadrangular resection versus triangular resection versus neochordoplasty
    • Padala M, Powell SN, Croft LR, Thourani VH, Yoganathan AP, Adams DH. Mitral valve hemodynamics after repair of acute posterior leaflet prolapse: quadrangular resection versus triangular resection versus neochordoplasty. J Thorac Cardiovasc Surg. 2009;138:309-315.
    • (2009) J Thorac Cardiovasc Surg , vol.138 , pp. 309-315
    • Padala, M.1    Powell, S.N.2    Croft, L.R.3    Thourani, V.H.4    Yoganathan, A.P.5    Adams, D.H.6
  • 10
    • 68249111128 scopus 로고    scopus 로고
    • Percutaneous mitral repair with the MitraClip system: Safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort
    • Feldman T, Kar S, Rinaldi M, et al. Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. J Am Coll Cardiol. 2009;54:686-694.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 686-694
    • Feldman, T.1    Kar, S.2    Rinaldi, M.3
  • 11
    • 79954487919 scopus 로고    scopus 로고
    • Percutaneous repair or surgery for mitral regurgitation
    • Feldman T, Foster E, Glower DD, et al. Percutaneous repair or surgery for mitral regurgitation. N Engl J Med. 2011;364:1395-1406.
    • (2011) N Engl J Med , vol.364 , pp. 1395-1406
    • Feldman, T.1    Foster, E.2    Glower, D.D.3
  • 12
    • 33644852948 scopus 로고    scopus 로고
    • Percutaneous transvenous mitral annuloplasty: Initial human experience with device implantation in the coronary sinus
    • Webb JG, Harnek J, Munt BI, et al. Percutaneous transvenous mitral annuloplasty: initial human experience with device implantation in the coronary sinus. Circulation. 2006;113:851-855.
    • (2006) Circulation , vol.113 , pp. 851-855
    • Webb, J.G.1    Harnek, J.2    Munt, B.I.3
  • 13
    • 78751650765 scopus 로고    scopus 로고
    • Transcatheter implantation of the MONARC coronary sinus device for mitral regurgitation: 1-year results from the EVOLUTION phase i study (Clinical Evaluation of the Edwards Lifesciences Percutaneous Mitral Annuloplasty System for the Treatment of Mitral Regurgitation
    • Harnek J, Webb JG, Kuck KH, et al. Transcatheter implantation of the MONARC coronary sinus device for mitral regurgitation: 1-year results from the EVOLUTION phase I study (Clinical Evaluation of the Edwards Lifesciences Percutaneous Mitral Annuloplasty System for the Treatment of Mitral Regurgitation). JACC Cardiovasc Interv. 2011;4: 115-122.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 115-122
    • Harnek, J.1    Webb, J.G.2    Kuck, K.H.3
  • 14
    • 84869436807 scopus 로고    scopus 로고
    • Direct access transcatheter mitral annuloplasty with a sutureless and adjustable device: Preclinical experience
    • Maisano F, Vanermen H, Seeburger J, et al. Direct access transcatheter mitral annuloplasty with a sutureless and adjustable device: preclinical experience. Eur J Cardiothorac Surg. 2012;42:524-529.
    • (2012) Eur J Cardiothorac Surg , vol.42 , pp. 524-529
    • Maisano, F.1    Vanermen, H.2    Seeburger, J.3
  • 15
    • 80052963107 scopus 로고    scopus 로고
    • Beating-heart implantation of adjustable length mitral valve chordae: Acute and chronic experience in an animal model
    • Maisano F, Cioni M, Seeburger J, et al. Beating-heart implantation of adjustable length mitral valve chordae: acute and chronic experience in an animal model. Eur J Cardiothorac Surg. 2011;40:840-847.
    • (2011) Eur J Cardiothorac Surg , vol.40 , pp. 840-847
    • Maisano, F.1    Cioni, M.2    Seeburger, J.3
  • 16
    • 58249088298 scopus 로고    scopus 로고
    • Beating-heart, off pump mitral valve repair by implantation of artificial chordae tendineae: An acute in vivo animal study
    • Bajona P, Katz WE, Daly RC, Zehr KJ, Speziali G. Beating-heart, off pump mitral valve repair by implantation of artificial chordae tendineae: An acute in vivo animal study. J Thorac Cardiovasc Surg. 2009;137: 188-193.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 188-193
    • Bajona, P.1    Katz, W.E.2    Daly, R.C.3    Zehr, K.J.4    Speziali, G.5
  • 18
    • 84860318839 scopus 로고    scopus 로고
    • Trans-apical beating-heart implantation of neochordae to mitral valve leaflets: Results of an acute animal study
    • Seeburger J, Leontjev S, Neumuth M, et al. Trans-apical beating-heart implantation of neochordae to mitral valve leaflets: results of an acute animal study. Eur J Cardiothorac Surg. 2011;41:173-176.
    • (2011) Eur J Cardiothorac Surg , vol.41 , pp. 173-176
    • Seeburger, J.1    Leontjev, S.2    Neumuth, M.3
  • 19
    • 67349214041 scopus 로고    scopus 로고
    • Inside the beating heart: An in vivo feasibility study on fusing pre and intra-operative imaging for minimally invasive therapy
    • Linte CA, Moore J, Wedlake C, et al. Inside the beating heart: an in vivo feasibility study on fusing pre and intra-operative imaging for minimally invasive therapy. Int J Comp Assist Radiol Surg. 2009;4:113-123.
    • (2009) Int J Comp Assist Radiol Surg , vol.4 , pp. 113-123
    • Linte, C.A.1    Moore, J.2    Wedlake, C.3
  • 20
    • 80052526884 scopus 로고    scopus 로고
    • Image-guided transapical aortic valve implantation: Sensorless tracking of stenotic valve landmarks in live fluoroscopic images
    • Merk DR, Karar ME, Chalopin C, et al. Image-guided transapical aortic valve implantation: sensorless tracking of stenotic valve landmarks in live fluoroscopic images. Innovations. 2011;6:231-236.
    • (2011) Innovations , vol.6 , pp. 231-236
    • Merk, D.R.1    Karar, M.E.2    Chalopin, C.3
  • 21
    • 84861193464 scopus 로고    scopus 로고
    • The critical role of imaging navigation and guidance in transcatheter aortic valve implantation
    • Lang P, Peters TM, Kiaii B, Chu MW. The critical role of imaging navigation and guidance in transcatheter aortic valve implantation. J Thorac Cardiovasc Surg. 2012;143:1241-1243.
    • (2012) J Thorac Cardiovasc Surg , vol.143 , pp. 1241-1243
    • Lang, P.1    Peters, T.M.2    Kiaii, B.3    Chu, M.W.4
  • 22
    • 44649147081 scopus 로고    scopus 로고
    • Stereoscopic vision display technology in real-time three-dimensional echocardiography-guided intracardiac beating-heart surgery
    • Vasilyev NV, Novotny PM, Martinez JF, et al. Stereoscopic vision display technology in real-time three-dimensional echocardiography-guided intracardiac beating-heart surgery. J Thorac Cardiovasc Surg. 2008;135: 1334-1341.
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 1334-1341
    • Vasilyev, N.V.1    Novotny, P.M.2    Martinez, J.F.3
  • 23
    • 84957066839 scopus 로고    scopus 로고
    • Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift
    • Gobbi D, Comeau R, Peters T. Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift. Med Image Comput Assist Interv. 1999;1679:920-927.
    • (1999) Med Image Comput Assist Interv , vol.1679 , pp. 920-927
    • Gobbi, D.1    Comeau, R.2    Peters, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.