메뉴 건너뛰기




Volumn 40, Issue 5, 2012, Pages 583-586

Manual neonatal ventilation training: A respiratory function monitor helps to reduce peak inspiratory pressures and tidal volumes during resuscitation

Author keywords

Neonate; Respiratory function monitor; Resuscitation; Self inflating bag; Training

Indexed keywords

ARTICLE; AUDIOVISUAL EQUIPMENT; HEALTH CARE PERSONNEL; HUMAN; MANUAL VENTILATION; MEDICAL EDUCATION; MONITOR; NEWBORN CARE; PEAK INSPIRATORY FLOW; PEAK INSPIRATORY PRESSURE; PRIORITY JOURNAL; RESPIRATORY FUNCTION; RESPIRATORY FUNCTION MONITOR; RESUSCITATION; TIDAL VOLUME;

EID: 84869475199     PISSN: 03005577     EISSN: 16193997     Source Type: Journal    
DOI: 10.1515/jpm-2012-0023     Document Type: Article
Times cited : (13)

References (18)
  • 1
    • 33745949739 scopus 로고    scopus 로고
    • Ventilatory strategies in the prevention and management of bronchopulmonary dysplasia
    • DOI 10.1053/j.semperi.2006.05.006, PII S0146000506000711, BPD: State of Art
    • Ambalavanan N, Carlo WA. Ventilatory strategies in the prevention and management of bronchopulmonary dysplasia. Semin Perinatol. 2006;30:192-9. (Pubitemid 44062677)
    • (2006) Seminars in Perinatology , vol.30 , Issue.4 , pp. 192-199
    • Ambalavanan, N.1    Carlo, W.A.2
  • 2
    • 25844483973 scopus 로고    scopus 로고
    • A comparison of three neonatal resuscitation devices
    • DOI 10.1016/j.resuscitation.2005.02.016, PII S0300957205001723
    • Bennett S, Finer NN, Rich W, Vaucher Y. A comparison of three neonatal resuscitation devices. Resuscitation. 2005;67:113-8. (Pubitemid 41394087)
    • (2005) Resuscitation , vol.67 , Issue.1 , pp. 113-118
    • Bennett, S.1    Finer, N.N.2    Rich, W.3    Vaucher, Y.4
  • 4
    • 0014064285 scopus 로고
    • The educated hand of the anesthesiologist. A study of professional skill
    • Egbert LD, Bisno D. The educated hand of the anesthesiologist. A study of professional skill. Anesth Analg. 1967;46: 195-200.
    • (1967) Anesth Analg. , vol.46 , pp. 195-200
    • Egbert, L.D.1    Bisno, D.2
  • 5
    • 0034960802 scopus 로고    scopus 로고
    • Comparison of methods of bag and mask ventilation for neonatal resuscitation
    • DOI 10.1016/S0300-9572(01)00311-2, PII S0300957201003112
    • Finer N, Rich W, Craft A, Henderson C. Comparison of methods of bag and mask ventilation for neonatal resuscitation. Resuscitation. 2001;49:299-305. (Pubitemid 32588708)
    • (2001) Resuscitation , vol.49 , Issue.3 , pp. 299-305
    • Finer, N.N.1    Rich, W.2    Craft, A.3    Henderson, C.4
  • 7
    • 78349300514 scopus 로고    scopus 로고
    • Part 15: Neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care
    • Kattwinkel J, Perlman JM, Aziz K, Colby C, Fairchild K, Gallagher J, et al. Part 15: neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2010;122:S909-19.
    • (2010) Circulation , vol.122
    • Kattwinkel, J.1    Perlman, J.M.2    Aziz, K.3    Colby, C.4    Fairchild, K.5    Gallagher, J.6
  • 8
    • 63149179835 scopus 로고    scopus 로고
    • Responding to compliance changes in a lung model during manual ventilation: Perhaps volume, rather than pressure, should be displayed
    • Kattwinkel J, Stewart C, Walsh B, Gurka M, Paget-Brown A. Responding to compliance changes in a lung model during manual ventilation: perhaps volume, rather than pressure, should be displayed. Pediatrics. 2009;123:E465-70.
    • (2009) Pediatrics. , vol.123
    • Kattwinkel, J.1    Stewart, C.2    Walsh, B.3    Gurka, M.4    Paget-Brown, A.5
  • 9
    • 33644860143 scopus 로고    scopus 로고
    • A survey of delivery room resuscitation practices in the United States
    • DOI 10.1542/peds.2005-0936
    • Leone TA, Rich W, Finer NN. A survey of delivery room resuscitation practices in the United States. Pediatrics. 2006;117:e164-75. (Pubitemid 46071570)
    • (2006) Pediatrics. , vol.117 , Issue.2
    • Leone, T.A.1    Rich, W.2    Finer, N.N.3
  • 10
    • 25844504166 scopus 로고    scopus 로고
    • Use of self-inflating bags for neonatal resuscitation
    • DOI 10.1016/j.resuscitation.2005.05.004, PII S030095720500211X
    • Oddie S, Wyllie J, Scally A. Use of self-inFlating bags for neonatal resuscitation. Resuscitation. 2005;67:109-12. (Pubitemid 41394086)
    • (2005) Resuscitation , vol.67 , Issue.1 , pp. 109-112
    • Oddie, S.1    Wyllie, J.2    Scally, A.3
  • 12
    • 78650209199 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2010 Section 7. Resuscitation of babies at birth
    • Richmond S, Wyllie J. European Resuscitation Council Guidelines for Resuscitation 2010 Section 7. Resuscitation of babies at birth. Resuscitation. 2010;81:1389-99.
    • (2010) Resuscitation , vol.81 , pp. 1389-1399
    • Richmond, S.1    Wyllie, J.2
  • 13
    • 78650222740 scopus 로고    scopus 로고
    • Delivery room management of very low birth weight infants in Germany, Austria and Switzerland - A comparison of protocols
    • Roehr CC, Gröbe S, Rüdiger M, Hummler H, Nelle M, Proquitt é H, et al. Delivery room management of very low birth weight infants in Germany, Austria and Switzerland - a comparison of protocols. Eur J Med Res. 2010;15:493-503.
    • (2010) Eur J Med Res. , vol.15 , pp. 493-503
    • Roehr, C.C.1    Gröbe, S.2    Rüdiger, M.3    Hummler, H.4    Nelle, M.5    Proquitté, H.6
  • 14
    • 74249104169 scopus 로고    scopus 로고
    • Manual ventilation devices in neonatal resuscitation: Tidal volume and positive pressure-provision
    • Roehr CC, Kelm M, Fischer HS, Bührer C, Schmalisch G, Proquitt é H. Manual ventilation devices in neonatal resuscitation: Tidal volume and positive pressure-provision. Resuscitation. 2010;81:202-5.
    • (2010) Resuscitation , vol.81 , pp. 202-225
    • Roehr, C.C.1    Kelm, M.2    Fischer, H.S.3    Bührer, C.4    Schmalisch, G.5    Proquitté, H.6
  • 15
    • 77956818762 scopus 로고    scopus 로고
    • Equipment and operator training denote manual ventilation performance in neonatal resuscitation
    • Roehr CC, Kelm M, Proquitte H, Schmalisch G. Equipment and operator training denote manual ventilation performance in neonatal resuscitation. Am J Perinatol. 2010;27:753-8.
    • (2010) Am J Perinatol. , vol.27 , pp. 753-758
    • Roehr, C.C.1    Kelm, M.2    Proquitte, H.3    Schmalisch, G.4
  • 16
    • 80052827999 scopus 로고    scopus 로고
    • Use of respiratory function monitors during simulated neonatal resuscitation
    • Schmölzer GM, Roehr CC. Use of respiratory function monitors during simulated neonatal resuscitation. Klin Padiatr. 2011;223:261-6.
    • (2011) Klin Padiatr. , vol.223 , pp. 261-266
    • Schmölzer, G.M.1    Roehr, C.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.