메뉴 건너뛰기




Volumn 46, Issue 22, 2012, Pages 12567-12574

Colloidal graphene as a transducer in homogeneous fluorescence-based immunosensor for rapid and sensitive analysis of microcystin-LR

Author keywords

[No Author keywords available]

Indexed keywords

ANTIGEN-ANTIBODY INTERACTION; BINDING AFFINITIES; BIOCONJUGATES; COMPETITIVE BINDING; COMPETITIVE MODE; DETECTION LIMITS; ENVIRONMENTAL SAMPLE; FLUORESCENCE SIGNALS; GUIDELINE LIMITS; HETEROGENEOUS IMMUNOASSAY; HOMOGENEOUS SOLUTIONS; MICROCYSTIN-LR; MICROCYSTINS; NONCOVALENT; OPTIMAL CONDITIONS; QUENCHING EFFICIENCY; SENSITIVE ANALYSIS; SENSITIVE DETECTION; SIGNAL TRANSDUCTION MECHANISM; STACKING INTERACTION; WASHING STEPS; WATER SAMPLES; WORLD HEALTH ORGANIZATION;

EID: 84869470444     PISSN: 0013936X     EISSN: 15205851     Source Type: Journal    
DOI: 10.1021/es3028583     Document Type: Article
Times cited : (60)

References (40)
  • 1
    • 8544226269 scopus 로고    scopus 로고
    • Oxidation of the cyanobacterial hepatotoxin microcystin-LR by chlorine dioxide: Reaction kinetics, characterization, and toxicity of reaction products
    • DOI 10.1021/es0400032
    • Kull, T. P. J.; Backlund, P. H.; Karlsson, K. M.; Meriluoto, J. A. O. Oxidation of the cyanobacterial hepatotoxin microcystin-LR by chlorine dioxide: Reaction kinetics, characterization, and toxicity of reaction products Environ. Sci. Technol. 2004, 38 (22) 6025-6031 (Pubitemid 39491874)
    • (2004) Environmental Science and Technology , vol.38 , Issue.22 , pp. 6025-6031
    • Kull, T.P.J.1    Backlund, P.H.2    Karlsson, K.M.3    Meriluoto, J.A.O.4
  • 3
    • 0025333146 scopus 로고
    • Cyanobacterial microcystin-LR is a potent and specific inhibitor of protein phosphatases 1 and 2A from both mammals and higher plants
    • DOI 10.1016/0014-5793(90)80245-E
    • MacKintosh, C.; Beattie, K. A.; Klumpp, S.; Cohen, P.; Codd, G. A. Cyanobacterial microcystin-LR is a potent and specific inhibitor of protein phosphatases 1 and 2A from both mammals and higher plants FEBS Lett. 1990, 264 (2) 187-192 (Pubitemid 20169213)
    • (1990) FEBS Letters , vol.264 , Issue.2 , pp. 187-192
    • MacKintosh, C.1    Beattie, K.A.2    Klumpp, S.3    Cohen, P.4    Codd, G.A.5
  • 4
    • 0037723070 scopus 로고    scopus 로고
    • Comparative toxicity evaluation of cyanobacterial cyclic peptide toxin microcystin variants (LR, RR, YR) in mice
    • DOI 10.1016/S0300-483X(03)00112-4
    • Gupta, N.; Pant, S. C.; Vijayaraghavan, R.; Rao, P. V. L Comparative toxicity evaluation of cyanobacterial cyclic peptide toxin microcystin variants (LR, RR, YR) in mice Toxicology 2003, 188 (2-3) 285-296 (Pubitemid 36588906)
    • (2003) Toxicology , vol.188 , Issue.2-3 , pp. 285-296
    • Gupta, N.1    Pant, S.C.2    Vijayaraghavan, R.3    Rao, P.V.L.4
  • 5
    • 0038672387 scopus 로고    scopus 로고
    • WHO. 2 nd ed. addendum to Vol. Health Criteria and Other Supporting Information; World Health Organization: Geneva, Switzerland
    • WHO. Guidelines for Drinking-Water Quality, 2 nd ed.; addendum to Vol. 2, Health Criteria and Other Supporting Information; World Health Organization: Geneva, Switzerland, 1998.
    • (1998) Guidelines for Drinking-Water Quality , vol.2
  • 6
    • 33749531035 scopus 로고    scopus 로고
    • Methods for determining microcystins (peptide hepatotoxins) and microcystin-producing cyanobacteria
    • DOI 10.1016/j.watres.2006.08.010, PII S0043135406004738
    • Sangolkar, L. N.; Maske, S. S.; Chakrabarti, T. Methods for determining microcystins (peptide hepatotoxins) and microcystin-producing cyanobacteria Water Res. 2006, 40 (19) 3485-3496 (Pubitemid 44527985)
    • (2006) Water Research , vol.40 , Issue.19 , pp. 3485-3496
    • Sangolkar, L.N.1    Maske, S.S.2    Chakrabarti, T.3
  • 7
    • 0037183453 scopus 로고    scopus 로고
    • Detection of microcystins with protein phosphatase inhibition assay, high-performance liquid chromatography-UV detection and enzyme-linked immunosorbent assay: Comparison of methods
    • Rapala, J.; Erkomaa, K.; Kukkonen, J.; Sivonen, K.; Lahti, K. Detection of microcystins with protein phosphatase inhibition assay, high-performance liquid chromatography-UV detection and enzyme-linked immunosorbent assay: Comparison of methods Anal. Chim. Acta 2002, 466 (2) 213-231
    • (2002) Anal. Chim. Acta , vol.466 , Issue.2 , pp. 213-231
    • Rapala, J.1    Erkomaa, K.2    Kukkonen, J.3    Sivonen, K.4    Lahti, K.5
  • 8
    • 11144225497 scopus 로고    scopus 로고
    • Towards the protein phosphatase-based biosensor for microcystin detection
    • DOI 10.1016/j.bios.2004.06.002, PII S095656630400243X
    • Campàs, M.; Szydlowska, D.; Trojanowicz, M.; Marty, J. L. Towards the protein phosphatase-based biosensor for microcystin detection Biosens. Bioelectron. 2005, 20 (8) 1520-1530 (Pubitemid 40051239)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.8 SPEC. ISS. , pp. 1520-1530
    • Campas, M.1    Szydlowska, D.2    Trojanowicz, M.3    Marty, J.-L.4
  • 9
    • 0037328127 scopus 로고    scopus 로고
    • Analysis of cyanobacterial toxins by immunological methods
    • DOI 10.1021/tx0200562
    • Metcalf, J. S.; Codd, G. A. Analysis of cyanobacterial toxins by immunological methods Chem. Res. Toxicol. 2003, 16 (2) 103-112 (Pubitemid 36245859)
    • (2003) Chemical Research in Toxicology , vol.16 , Issue.2 , pp. 103-112
    • Metcalf, J.S.1    Codd, G.A.2
  • 10
    • 62649097700 scopus 로고    scopus 로고
    • Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples
    • Long, F.; He, M.; Zhu, A. N.; Shi, H. C. Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples Biosens. Bioelectron. 2009, 24 (8) 2346-2351
    • (2009) Biosens. Bioelectron. , vol.24 , Issue.8 , pp. 2346-2351
    • Long, F.1    He, M.2    Zhu, A.N.3    Shi, H.C.4
  • 11
    • 0037998212 scopus 로고    scopus 로고
    • Development of an ultrarapid one-step fluorescence immunochromatographic assay system for the quantification of microcystins
    • DOI 10.1021/es026191i
    • Kim, Y. M.; Oh, S. W.; Jeong, S. Y.; Pyo, D. J.; Choi, E. Y. Development of an ultrarapid one-step fluorescence immunochromatographic assay system for the quantification of microcystins Environ. Sci. Technol. 2003, 37 (9) 1899-1904 (Pubitemid 36534765)
    • (2003) Environmental Science and Technology , vol.37 , Issue.9 , pp. 1899-1904
    • Kim, Y.M.1    Oh, S.W.2    Jeong, S.Y.3    Pyo, D.J.4    Choi, E.Y.5
  • 12
    • 67949115628 scopus 로고    scopus 로고
    • Sensitive and rapid chemiluminescence enzyme immunoassay for microcystin-LR in water samples
    • Long, F.; Shi, H. C.; He, M.; Sheng, J. W.; Wang, J. F. Sensitive and rapid chemiluminescence enzyme immunoassay for microcystin-LR in water samples Anal. Chim. Acta 2009, 649 (1) 123-127
    • (2009) Anal. Chim. Acta , vol.649 , Issue.1 , pp. 123-127
    • Long, F.1    Shi, H.C.2    He, M.3    Sheng, J.W.4    Wang, J.F.5
  • 13
    • 4143122206 scopus 로고    scopus 로고
    • Development of a highly sensitive inhibition immunoassay for microcystin-LR
    • DOI 10.1016/j.aca.2004.05.059, PII S0003267004006695
    • Lindner, P.; Molz, R.; Yacoub-George, E.; Dürkop, A.; Wolf, H. Development of a highly sensitive inhibition immunoassay for microcystin-LR Anal. Chim. Acta 2004, 521 (1) 37-44 (Pubitemid 39092875)
    • (2004) Analytica Chimica Acta , vol.521 , Issue.1 , pp. 37-44
    • Lindner, P.1    Molz, R.2    Yacoub-George, E.3    Durkop, A.4    Wolf, H.5
  • 14
    • 33846350216 scopus 로고    scopus 로고
    • A rapid competitive binding nonseparation electrochemical enzyme immunoassay (NEEIA) test strip for microcystin-LR (MCLR) determination
    • DOI 10.1016/j.bios.2006.06.021, PII S0956566306002843
    • Zhang, F.; Yang, S. H.; Kang, T. Y.; Cha, G. S.; Nam, H.; Meyerhoff, M. E. A rapid competitive binding nonseparation electrochemical enzyme immunoassay (NEEIA) test strip for microcystin-LR (MCLR) determination Biosens. Bioelectron. 2007, 22 (7) 1419-1425 (Pubitemid 46135991)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.7 , pp. 1419-1425
    • Zhang, F.1    Yang, S.H.2    Kang, T.Y.3    Cha, G.S.4    Nam, H.5    Meyerhoff, M.E.6
  • 15
    • 33845416939 scopus 로고    scopus 로고
    • Highly sensitive amperometric immunosensors for microcystin detection in algae
    • DOI 10.1016/j.bios.2006.04.025, PII S0956566306002314
    • Campàs, M.; Marty, J. L. Highly sensitive amperometric immunosensors for microcystin detection in algae Biosens. Bioelectron. 2007, 22 (6) 1034-1040 (Pubitemid 44894895)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.6 , pp. 1034-1040
    • Campas, M.1    Marty, J.-L.2
  • 16
    • 84861126478 scopus 로고    scopus 로고
    • A membrane-based ELISA assay and electrochemical immunosensor for microcystin-LR in water samples
    • Lotierzo, M.; Abuknesha, R.; Davis, F.; Tothill, I. E. A membrane-based ELISA assay and electrochemical immunosensor for microcystin-LR in water samples Environ. Sci. Technol. 2012, 46 (10) 5504-5510
    • (2012) Environ. Sci. Technol. , vol.46 , Issue.10 , pp. 5504-5510
    • Lotierzo, M.1    Abuknesha, R.2    Davis, F.3    Tothill, I.E.4
  • 17
    • 35248880258 scopus 로고    scopus 로고
    • A highly specific immunoassay for microcystin-LR detection based on a monoclonal antibody
    • DOI 10.1016/j.aca.2007.09.029, PII S0003267007015656
    • Sheng, J. W.; He, M.; Shi, H. C. A highly specific immunoassay for microcystin-LR detection based on a monoclonal antibody Anal. Chim. Acta 2007, 603 (1) 111-118 (Pubitemid 47562354)
    • (2007) Analytica Chimica Acta , vol.603 , Issue.1 , pp. 111-118
    • Sheng, J.-W.1    He, M.2    Shi, H.-C.3
  • 18
    • 82955207131 scopus 로고    scopus 로고
    • Nanoporous PtRu alloy enhanced nonenzymatic immunosensor for ultrasensitive detection of microcystin-LR
    • Wei, Q.; Zhao, Y. F.; Du, B.; Wu, D.; Cai, Y. Y.; Mao, K. X.; Li, H.; Xu, C. X. Nanoporous PtRu alloy enhanced nonenzymatic immunosensor for ultrasensitive detection of microcystin-LR Adv. Funct. Mater. 2011, 21 (21) 4193-4198
    • (2011) Adv. Funct. Mater. , vol.21 , Issue.21 , pp. 4193-4198
    • Wei, Q.1    Zhao, Y.F.2    Du, B.3    Wu, D.4    Cai, Y.Y.5    Mao, K.X.6    Li, H.7    Xu, C.X.8
  • 19
    • 71949095893 scopus 로고    scopus 로고
    • Simple, rapid, sensitive, and versatile SWNT-paper sensor for environmental toxin detection competitive with ELISA
    • Wang, L.; Chen, W.; Xu, D.; Shim, B.; Zhu, Y.; Sun, F.; Liu, L.; Peng, C.; Jin, Z.; Xu, C.; Kotov, N. A. Simple, rapid, sensitive, and versatile SWNT-paper sensor for environmental toxin detection competitive with ELISA Nano Lett. 2009, 9 (12) 4147-4152
    • (2009) Nano Lett. , vol.9 , Issue.12 , pp. 4147-4152
    • Wang, L.1    Chen, W.2    Xu, D.3    Shim, B.4    Zhu, Y.5    Sun, F.6    Liu, L.7    Peng, C.8    Jin, Z.9    Xu, C.10    Kotov, N.A.11
  • 20
    • 76149083240 scopus 로고    scopus 로고
    • Carbon nanohorn sensitized electrochemical immunosensor for rapid detection of microcystin-LR
    • Zhang, J.; Lei, J. P.; Xu, C. L.; Ding, L.; Ju, H. X. Carbon nanohorn sensitized electrochemical immunosensor for rapid detection of microcystin-LR Anal. Chem. 2010, 82 (3) 1117-1122
    • (2010) Anal. Chem. , vol.82 , Issue.3 , pp. 1117-1122
    • Zhang, J.1    Lei, J.P.2    Xu, C.L.3    Ding, L.4    Ju, H.X.5
  • 22
    • 79959241244 scopus 로고    scopus 로고
    • G-quadruplex DNAzyme-based microcystin-LR (toxin) determination by a novel immunosensor
    • Zhu, Y. Y.; Xu, L. G.; Ma, W.; Chen, W.; Yan, W. J.; Kuang, H.; Wang, L. B.; Xu, C. L. G-quadruplex DNAzyme-based microcystin-LR (toxin) determination by a novel immunosensor Biosens. Bioelectron. 2011, 26 (11) 4393-4398
    • (2011) Biosens. Bioelectron. , vol.26 , Issue.11 , pp. 4393-4398
    • Zhu, Y.Y.1    Xu, L.G.2    Ma, W.3    Chen, W.4    Yan, W.J.5    Kuang, H.6    Wang, L.B.7    Xu, C.L.8
  • 24
    • 46149122724 scopus 로고    scopus 로고
    • Label-free capacitive immunosensor for microcystin-LR using self-assembled thiourea monolayer incorporated with Ag nanoparticles on gold electrode
    • Loyprasert, S.; Thavarungkul, P.; Asawatreratanakul, P.; Wongkittsuksa, B.; Limsakul, C.; Kanatharana, P. Label-free capacitive immunosensor for microcystin-LR using self-assembled thiourea monolayer incorporated with Ag nanoparticles on gold electrode Biosens. Bioelectron. 2008, 24 (1) 78-86
    • (2008) Biosens. Bioelectron. , vol.24 , Issue.1 , pp. 78-86
    • Loyprasert, S.1    Thavarungkul, P.2    Asawatreratanakul, P.3    Wongkittsuksa, B.4    Limsakul, C.5    Kanatharana, P.6
  • 25
  • 26
    • 80052714095 scopus 로고    scopus 로고
    • Bead-based competitive fluorescence immunoassay for sensitive and rapid diagnosis of cyanotoxin risk in drinking water
    • Yu, H. W.; Jang, A.; Kim, L. H.; Kim, S. J.; Kim, I. S. Bead-based competitive fluorescence immunoassay for sensitive and rapid diagnosis of cyanotoxin risk in drinking water Environ. Sci. Technol. 2011, 45 (18) 7804-7811
    • (2011) Environ. Sci. Technol. , vol.45 , Issue.18 , pp. 7804-7811
    • Yu, H.W.1    Jang, A.2    Kim, L.H.3    Kim, S.J.4    Kim, I.S.5
  • 27
    • 84755160636 scopus 로고    scopus 로고
    • Compact quantitative optic fiber-based immunoarray biosensor for rapid detection of small analytes
    • Long, F.; He, M.; Zhu, A.; Song, B. D.; Sheng, J. W.; Shi, H. C. Compact quantitative optic fiber-based immunoarray biosensor for rapid detection of small analytes Biosens. Bioelectron. 2010, 26 (1) 16-22
    • (2010) Biosens. Bioelectron. , vol.26 , Issue.1 , pp. 16-22
    • Long, F.1    He, M.2    Zhu, A.3    Song, B.D.4    Sheng, J.W.5    Shi, H.C.6
  • 28
    • 84857356057 scopus 로고    scopus 로고
    • Automated portable array biosensor for multisample microcystin analysis in freshwater samples
    • Herranz, S.; Marazuela, M. D.; Moreno-Bondi, M. C. Automated portable array biosensor for multisample microcystin analysis in freshwater samples Biosens. Bioelectron. 2012, 33 (1) 50-55
    • (2012) Biosens. Bioelectron. , vol.33 , Issue.1 , pp. 50-55
    • Herranz, S.1    Marazuela, M.D.2    Moreno-Bondi, M.C.3
  • 30
    • 79951662173 scopus 로고    scopus 로고
    • Highly sensitive and rapid detection of microcystin-LR in source and finished water samples using cantilever sensors
    • Ding, Y.; Mutharasan, R. Highly sensitive and rapid detection of microcystin-LR in source and finished water samples using cantilever sensors Environ. Sci. Technol. 2011, 45 (4) 1490-1496
    • (2011) Environ. Sci. Technol. , vol.45 , Issue.4 , pp. 1490-1496
    • Ding, Y.1    Mutharasan, R.2
  • 31
    • 81255129158 scopus 로고    scopus 로고
    • Graphene and its derivative-based sensing materials for analytical devices
    • Guo, S. J.; Dong, S. J. Graphene and its derivative-based sensing materials for analytical devices J. Mater. Chem. 2011, 21 (46) 18503-18516
    • (2011) J. Mater. Chem. , vol.21 , Issue.46 , pp. 18503-18516
    • Guo, S.J.1    Dong, S.J.2
  • 32
    • 84862731002 scopus 로고    scopus 로고
    • Graphene oxide as an optical biosensing platform
    • Morales-Narváez, E.; Merkoçi, A. Graphene oxide as an optical biosensing platform Adv. Mater. 2012, 24 (25) 3298-3308
    • (2012) Adv. Mater. , vol.24 , Issue.25 , pp. 3298-3308
    • Morales-Narváez, E.1    Merkoçi, A.2
  • 33
    • 80054712237 scopus 로고    scopus 로고
    • Colorimetric biosensing using smart materials
    • Song, Y.; Wei, W.; Qu, X. Colorimetric biosensing using smart materials Adv. Mater. 2011, 23 (27) 4215-4236
    • (2011) Adv. Mater. , vol.23 , Issue.27 , pp. 4215-4236
    • Song, Y.1    Wei, W.2    Qu, X.3
  • 36
    • 49349118143 scopus 로고    scopus 로고
    • Resonance energy transfer from a dye molecule to graphene
    • Swathi, R. S.; Sebastian, K. L. Resonance energy transfer from a dye molecule to graphene J. Chem. Phys. 2008, 129, 054703
    • (2008) J. Chem. Phys. , vol.129 , pp. 054703
    • Swathi, R.S.1    Sebastian, K.L.2
  • 37
    • 84860365592 scopus 로고    scopus 로고
    • Interface engineering catalytic graphene for smart colorimetric biosensing
    • Liu, M.; Zhao, H.; Chen, S.; Yu, H.; Quan, X. Interface engineering catalytic graphene for smart colorimetric biosensing ACS Nano 2012, 6 (4) 3142-3151
    • (2012) ACS Nano , vol.6 , Issue.4 , pp. 3142-3151
    • Liu, M.1    Zhao, H.2    Chen, S.3    Yu, H.4    Quan, X.5
  • 38
    • 38949108623 scopus 로고    scopus 로고
    • Processable aqueous dispersions of graphene nanosheets
    • DOI 10.1038/nnano.2007.451, PII NNANO2007451
    • Li, D.; Müller, M. B.; Gilje, S.; Kaner, R. B.; Wallace, G. G. Processable aqueous dispersions of graphene nanosheets Nat. Nanotechnol. 2008, 3 (2) 101-105 (Pubitemid 351225404)
    • (2008) Nature Nanotechnology , vol.3 , Issue.2 , pp. 101-105
    • Li, D.1    Muller, M.B.2    Gilje, S.3    Kaner, R.B.4    Wallace, G.G.5
  • 39
    • 67650684978 scopus 로고    scopus 로고
    • Hydrothermal dehydration for the "green" reduction of exfoliated graphene oxide to graphene and demonstration of tunable optical limiting properties
    • Zhou, Y.; Bao, Q. L.; Tang, L. A. L.; Zhong, Y. L.; Loh, K. P. Hydrothermal dehydration for the "green" reduction of exfoliated graphene oxide to graphene and demonstration of tunable optical limiting properties Chem. Mater. 2009, 21 (13) 2950-2956
    • (2009) Chem. Mater. , vol.21 , Issue.13 , pp. 2950-2956
    • Zhou, Y.1    Bao, Q.L.2    Tang, L.A.L.3    Zhong, Y.L.4    Loh, K.P.5
  • 40
    • 78649527520 scopus 로고    scopus 로고
    • Graphene oxide as a chemically tunable platform for optical applications
    • Loh, K. P.; Bao, Q.; Eda, G.; Chhowalla, M. Graphene oxide as a chemically tunable platform for optical applications Nat. Chem. 2010, 2 (12) 1015-1024
    • (2010) Nat. Chem. , vol.2 , Issue.12 , pp. 1015-1024
    • Loh, K.P.1    Bao, Q.2    Eda, G.3    Chhowalla, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.