-
2
-
-
0000064839
-
Some early developments in synthetic aperture radar systems
-
C.W. Sherwin, J.P. Ruina, and D. Rawcliffe Some early developments in synthetic aperture radar systems IRE Trans. Mil. Elect. MIL-6 1962 111 115
-
(1962)
IRE Trans. Mil. Elect.
, vol.6 MIL-
, pp. 111-115
-
-
Sherwin, C.W.1
Ruina, J.P.2
Rawcliffe, D.3
-
8
-
-
0021466923
-
Real-time digital image reconstruction: A description of imaging hardware and an analysis of quantization errors
-
D.K. Peterson, and G.S. Kino Real-time digital image reconstruction: a description of imaging hardware and an analysis of quantization errors IEEE Trans. Son. Ultrason. 31 1984 337 351
-
(1984)
IEEE Trans. Son. Ultrason.
, vol.31
, pp. 337-351
-
-
Peterson, D.K.1
Kino, G.S.2
-
10
-
-
0032636279
-
Theoretical assessment of a synthetic aperture beamformer for real-time 3-D imaging
-
C.R. Hazard, and G.R. Lockwood Theoretical assessment of a synthetic aperture beamformer for real-time 3-D imaging IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 46 1999 972 980
-
(1999)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.46
, pp. 972-980
-
-
Hazard, C.R.1
Lockwood, G.R.2
-
11
-
-
0026868890
-
Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging
-
M. O'Donnell, and L.J. Thomas Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 39 1992 366 380
-
(1992)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.39
, pp. 366-380
-
-
O'Donnell, M.1
Thomas, L.J.2
-
12
-
-
0030196861
-
A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics
-
C. Passmann, and H. Ermert A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 43 1996 545 552
-
(1996)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.43
, pp. 545-552
-
-
Passmann, C.1
Ermert, H.2
-
14
-
-
0036034664
-
Virtual ultrasound sources in high-resolution ultrasound imaging
-
S.I. Nikolov, J.A. Jensen, Virtual ultrasound sources in high-resolution ultrasound imaging, in: Proc. SPIE - Progress in biomedical optics and imaging, vol. 3, 2002, pp. 395-405.
-
(2002)
Proc. SPIE - Progress in Biomedical Optics and Imaging
, vol.3
, pp. 395-405
-
-
Nikolov, S.I.1
Jensen, J.A.2
-
15
-
-
0034580075
-
3D synthetic aperture imaging using a virtual source element in the elevation plane
-
S.I. Nikolov, J.A. Jensen, 3D synthetic aperture imaging using a virtual source element in the elevation plane, in: Proc. IEEE Ultrason. Symp. vol. 2, 2000, pp. 1743-1747.
-
(2000)
Proc. IEEE Ultrason. Symp.
, vol.2
, pp. 1743-1747
-
-
Nikolov, S.I.1
Jensen, J.A.2
-
16
-
-
0034315840
-
A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems
-
M.H. Bae, and M.K. Jeong A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 47 2000 1510 1519
-
(2000)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.47
, pp. 1510-1519
-
-
Bae, M.H.1
Jeong, M.K.2
-
17
-
-
48149101087
-
Synthetic aperture focusing applied to imaging using a rotating single element transducer
-
J. Kortbek, J.A. Jensen, K.L. Gammelmark, Synthetic aperture focusing applied to imaging using a rotating single element transducer, in: Proc. IEEE Ultrason. Symp. 2007, pp. 1504-1507.
-
(2007)
Proc. IEEE Ultrason. Symp.
, pp. 1504-1507
-
-
Kortbek, J.1
Jensen, J.A.2
Gammelmark, K.L.3
-
18
-
-
0026838720
-
Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
-
J.A. Jensen, and N.B. Svendsen Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 39 1992 262 267
-
(1992)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.39
, pp. 262-267
-
-
Jensen, J.A.1
Svendsen, N.B.2
-
20
-
-
35148832649
-
Effective and versatile software beamformation toolbox
-
651319
-
J. Kortbek, S.I. Nikolov, J.A. Jensen, Effective and versatile software beamformation toolbox, in: Proc. SPIE - Medical Imaging - Ultrasonic Imaging and Signal Processsing, vol. 651319, 2007, pp. 1-10.
-
(2007)
Proc. SPIE - Medical Imaging - Ultrasonic Imaging and Signal Processsing
, pp. 1-10
-
-
Kortbek, J.1
Nikolov, S.I.2
Jensen, J.A.3
-
22
-
-
84942213276
-
Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogenities - Part I: Basic principles
-
L.F. Nock, and G.E. Trahey Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogenities - Part I: basic principles IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 39 1992 489 495
-
(1992)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.39
, pp. 489-495
-
-
Nock, L.F.1
Trahey, G.E.2
-
23
-
-
0000474501
-
Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogenities - Part II: Effects of and correction for motion
-
G.E. Trahey, and L.F. Nock Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogenities - Part II: effects of and correction for motion IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 39 1992 496 501
-
(1992)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.39
, pp. 496-501
-
-
Trahey, G.E.1
Nock, L.F.2
-
24
-
-
0030351754
-
Motion estimation using common spatial frequencies in synthetic aperture imaging
-
H.Ş. Bilge, M. Karaman, M. O'Donnell, Motion estimation using common spatial frequencies in synthetic aperture imaging, in: Proc. IEEE Ultrason. Symp. 1996, pp. 1551-1554.
-
(1996)
Proc. IEEE Ultrason. Symp.
, pp. 1551-1554
-
-
H. Ş. Bilge1
-
25
-
-
0032115862
-
Adaptive multi-element synthetic aperture imaging with motion and phase aberration correction
-
M. Karaman, H.Ş. Bilge, and M. O'Donnell Adaptive multi-element synthetic aperture imaging with motion and phase aberration correction IEEE Trans. Ultrason. Ferroelec. Freq. Contr. 42 1998 1077 1087
-
(1998)
IEEE Trans. Ultrason. Ferroelec. Freq. Contr.
, vol.42
, pp. 1077-1087
-
-
Karaman, M.1
Bilge, H.Ş.2
O'Donnell, M.3
-
26
-
-
0033295063
-
Effects of motion artifacts on a synthetic aperture beamformer for real-time 3D ultrasound
-
C.R. Hazard, G.R. Lockwood, Effects of motion artifacts on a synthetic aperture beamformer for real-time 3D ultrasound, in: Proc. IEEE Ultrason. Symp. 1999, pp. 1221-1224.
-
(1999)
Proc. IEEE Ultrason. Symp.
, pp. 1221-1224
-
-
Hazard, C.R.1
Lockwood, G.R.2
-
27
-
-
0034579682
-
Effects and limitations of motion compensation in synthetic aperture techniques
-
J.S. Jeong, J.S. Hwang, M.H. Bae, T.K. Song, Effects and limitations of motion compensation in synthetic aperture techniques, in: Proc. IEEE Ultrason. Symp. 2000, pp. 1759 -1762.
-
(2000)
Proc. IEEE Ultrason. Symp.
, pp. 1759-1762
-
-
Jeong, J.S.1
Hwang, J.S.2
Bae, M.H.3
Song, T.K.4
-
28
-
-
4143088474
-
K-space model of motion artifacts in synthetic transmit aperture ultrasound imaging
-
S.I. Nikolov, J.A. Jensen, K-space model of motion artifacts in synthetic transmit aperture ultrasound imaging, in: Proc. IEEE Ultrason. Symp. 2003, pp. 1824-1828.
-
(2003)
Proc. IEEE Ultrason. Symp.
, pp. 1824-1828
-
-
Nikolov, S.I.1
Jensen, J.A.2
-
29
-
-
85047688862
-
Multielement synthetic transmit aperture imaging using temporal encoding
-
K.L. Gammelmark, and J.A. Jensen Multielement synthetic transmit aperture imaging using temporal encoding IEEE Trans. Med. Imag. 22 2003 552 563
-
(2003)
IEEE Trans. Med. Imag.
, vol.22
, pp. 552-563
-
-
Gammelmark, K.L.1
Jensen, J.A.2
-
30
-
-
4143057975
-
Duplex synthetic aperture imaging with tissue motion compensation
-
K.L. Gammelmark, J.A. Jensen, Duplex synthetic aperture imaging with tissue motion compensation, in: Proc. IEEE Ultrason. Symp. 2003, pp. 1569-1573.
-
(2003)
Proc. IEEE Ultrason. Symp.
, pp. 1569-1573
-
-
Gammelmark, K.L.1
Jensen, J.A.2
-
31
-
-
0033293675
-
Recursive ultrasound imaging
-
S.I. Nikolov, K. Gammelmark, J.A. Jensen, Recursive ultrasound imaging, in: Proc. IEEE Ultrason. Symp. vol. 2, 1999, pp. 1621-1625.
-
(1999)
Proc. IEEE Ultrason. Symp.
, vol.2
, pp. 1621-1625
-
-
Nikolov, S.I.1
Gammelmark, K.2
Jensen, J.A.3
|