메뉴 건너뛰기




Volumn 5, Issue 11, 2012, Pages 1147-1155

Quantitative and qualitative changes in DES-related neointimal tissue based on serial OCT

Author keywords

neointima; optical coherence tomography; stent

Indexed keywords

EVEROLIMUS; PACLITAXEL; RAPAMYCIN; ZOTAROLIMUS;

EID: 84869098386     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2012.01.024     Document Type: Article
Times cited : (66)

References (29)
  • 1
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • J.W. Moses, M.B. Leon, J.J. Popma Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery N Engl J Med 349 2003 1315 1323
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 2
    • 9144249927 scopus 로고    scopus 로고
    • A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease
    • G.W. Stone, S.G. Ellis, D.A. Cox A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease N Engl J Med 350 2004 221 231
    • (2004) N Engl J Med , vol.350 , pp. 221-231
    • Stone, G.W.1    Ellis, S.G.2    Cox, D.A.3
  • 3
    • 33847167065 scopus 로고    scopus 로고
    • Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study
    • J. Daemen, P. Wenaweser, K. Tsuchida Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study Lancet 369 2007 667 678
    • (2007) Lancet , vol.369 , pp. 667-678
    • Daemen, J.1    Wenaweser, P.2    Tsuchida, K.3
  • 4
    • 33845319222 scopus 로고    scopus 로고
    • Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: An observational study of drug-eluting versus bare-metal stents
    • M. Pfisterer, H.P. Brunner-La Rocca, P.T. Buser Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents J Am Coll Cardiol 48 2006 2584 2591
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2584-2591
    • Pfisterer, M.1    Brunner-La Rocca, H.P.2    Buser, P.T.3
  • 5
    • 34248219973 scopus 로고    scopus 로고
    • Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization
    • A.V. Finn, M. Joner, G. Nakazawa Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization Circulation 115 2007 2435 2441
    • (2007) Circulation , vol.115 , pp. 2435-2441
    • Finn, A.V.1    Joner, M.2    Nakazawa, G.3
  • 6
    • 79952414020 scopus 로고    scopus 로고
    • The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents
    • G. Nakazawa, F. Otsuka, M. Nakano The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents J Am Coll Cardiol 57 2011 1314 1322
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1314-1322
    • Nakazawa, G.1    Otsuka, F.2    Nakano, M.3
  • 7
    • 77952295017 scopus 로고    scopus 로고
    • Intravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation
    • C.W. Lee, S.J. Kang, D.W. Park Intravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation J Am Coll Cardiol 55 2010 1936 1942
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1936-1942
    • Lee, C.W.1    Kang, S.J.2    Park, D.W.3
  • 8
    • 72549090920 scopus 로고    scopus 로고
    • Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography
    • M. Takano, M. Yamamoto, S. Inami Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography J Am Coll Cardiol 55 2009 26 32
    • (2009) J Am Coll Cardiol , vol.55 , pp. 26-32
    • Takano, M.1    Yamamoto, M.2    Inami, S.3
  • 9
    • 75249103029 scopus 로고    scopus 로고
    • Intracoronary thrombus formation after drug-eluting stents implantation: Optical coherence tomographic study
    • J.S. Kim, M.K. Hong, C. Fan Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study Am Heart J 159 2010 278 283
    • (2010) Am Heart J , vol.159 , pp. 278-283
    • Kim, J.S.1    Hong, M.K.2    Fan, C.3
  • 10
    • 72149133094 scopus 로고    scopus 로고
    • Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: The ENDEAVOR OCT trial
    • J.S. Kim, I.K. Jang, C. Fan Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial J Am Coll Cardiol Intv 2 2009 1240 1247
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 1240-1247
    • Kim, J.S.1    Jang, I.K.2    Fan, C.3
  • 11
    • 40749148045 scopus 로고    scopus 로고
    • Intravascular optical coherence tomography: Optimisation of image acquisition and quantitative assessment of stent strut apposition
    • J. Tanigawa, P. Barlis, C. Di Mario Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition EuroIntervention 3 2007 128 136
    • (2007) EuroIntervention , vol.3 , pp. 128-136
    • Tanigawa, J.1    Barlis, P.2    Di Mario, C.3
  • 12
    • 64849091370 scopus 로고    scopus 로고
    • The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography
    • J. Tanigawa, P. Barlis, K. Dimopoulos, M. Dalby, P. Moore, C. Di Mario The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography Int J Cardiol 134 2009 180 188
    • (2009) Int J Cardiol , vol.134 , pp. 180-188
    • Tanigawa, J.1    Barlis, P.2    Dimopoulos, K.3    Dalby, M.4    Moore, P.5    Di Mario, C.6
  • 13
    • 84861482050 scopus 로고    scopus 로고
    • Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: Comparison with sirolimus-eluting stent using optical coherence tomography
    • H.H. Choi, J.S. Kim, D.H. Yoon Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography Int J Cardiovasc Imaging 28 2012 491 497
    • (2012) Int J Cardiovasc Imaging , vol.28 , pp. 491-497
    • Choi, H.H.1    Kim, J.S.2    Yoon, D.H.3
  • 14
    • 67650361247 scopus 로고    scopus 로고
    • Optical coherence tomography patterns of stent restenosis
    • N. Gonzalo, P.W. Serruys, T. Okamura Optical coherence tomography patterns of stent restenosis Am Heart J 158 2009 284 293
    • (2009) Am Heart J , vol.158 , pp. 284-293
    • Gonzalo, N.1    Serruys, P.W.2    Okamura, T.3
  • 15
    • 33644874009 scopus 로고    scopus 로고
    • Optical coherence tomography findings at 5-year follow-up after coronary stent implantation
    • E. Regar, H.M.M. van Beusekom, W.J. van der Gissen, P.W. Serruys Optical coherence tomography findings at 5-year follow-up after coronary stent implantation Circulation 112 2005 e345 e346
    • (2005) Circulation , vol.112
    • Regar, E.1    Van Beusekom, H.M.M.2    Van Der Gissen, W.J.3    Serruys, P.W.4
  • 16
    • 78650159117 scopus 로고    scopus 로고
    • Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: Serial observations by intracoronary optical coherence tomography
    • M. Takano, M. Yamamoto, M. Mizuno Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: serial observations by intracoronary optical coherence tomography Circ Cardiovasc Interv 3 2010 476 483
    • (2010) Circ Cardiovasc Interv , vol.3 , pp. 476-483
    • Takano, M.1    Yamamoto, M.2    Mizuno, M.3
  • 17
    • 34447634702 scopus 로고    scopus 로고
    • Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal stent coronary interventions
    • L.O. Jensen, M. Maeng, A. Kaltoft Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal stent coronary interventions J Am Coll Cardiol 50 2007 463 470
    • (2007) J Am Coll Cardiol , vol.50 , pp. 463-470
    • Jensen, L.O.1    Maeng, M.2    Kaltoft, A.3
  • 18
    • 0141885290 scopus 로고    scopus 로고
    • Pathological mechanisms of fatal late coronary stent thrombosis in humans
    • A. Farb, A.P. Burke, F.D. Kolodgie, R. Virmani Pathological mechanisms of fatal late coronary stent thrombosis in humans Circulation 108 2003 1701 1706
    • (2003) Circulation , vol.108 , pp. 1701-1706
    • Farb, A.1    Burke, A.P.2    Kolodgie, F.D.3    Virmani, R.4
  • 19
    • 34147135208 scopus 로고    scopus 로고
    • Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation
    • M. Takano, S. Inami, I.K. Jang Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation Am J Cardiol 99 2007 1033 1038
    • (2007) Am J Cardiol , vol.99 , pp. 1033-1038
    • Takano, M.1    Inami, S.2    Jang, I.K.3
  • 20
    • 34548329438 scopus 로고    scopus 로고
    • Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: Evaluated by optical coherence tomography
    • D. Matsumoto, J. Shite, T. Shinke Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography Eur Heart J 28 2007 961 967
    • (2007) Eur Heart J , vol.28 , pp. 961-967
    • Matsumoto, D.1    Shite, J.2    Shinke, T.3
  • 21
    • 77954746572 scopus 로고    scopus 로고
    • Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents
    • G. Guagliumi, G. Musumeci, V. Sirbu Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents J Am Coll Cardiol Intv 3 2010 531 539
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 531-539
    • Guagliumi, G.1    Musumeci, G.2    Sirbu, V.3
  • 22
    • 77951723057 scopus 로고    scopus 로고
    • Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure - 6-month follow-up - 6-month f
    • N. Miyoshi, J. Shite, T. Shinke Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure - 6-month follow-up - Circ J 74 2010 903 908
    • (2010) Circ J , vol.74 , pp. 903-908
    • Miyoshi, N.1    Shite, J.2    Shinke, T.3
  • 23
    • 72049117874 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: Comparison with sirolimus-eluting stents
    • J.S. Kim, I.K. Jang, T.H. Kim Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents Heart 95 2009 1907 1912
    • (2009) Heart , vol.95 , pp. 1907-1912
    • Kim, J.S.1    Jang, I.K.2    Kim, T.H.3
  • 24
    • 75749123502 scopus 로고    scopus 로고
    • Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation
    • J.S. Kim, T.H. Kim, C. Fan Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation Circ J 74 2010 320 326
    • (2010) Circ J , vol.74 , pp. 320-326
    • Kim, J.S.1    Kim, T.H.2    Fan, C.3
  • 25
    • 83955163002 scopus 로고    scopus 로고
    • Long-term (<2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: Comparison to 9-month follow-up results
    • T.H. Kim, J.S. Kim, B.K. Kim Long-term (<2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: comparison to 9-month follow-up results Int J Cardiovasc Imaging 27 2011 875 881
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 875-881
    • Kim, T.H.1    Kim, J.S.2    Kim, B.K.3
  • 26
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk
    • M. Joner, A.V. Finn, A. Farb Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk J Am Coll Cardiol 48 2006 193 202
    • (2006) J Am Coll Cardiol , vol.48 , pp. 193-202
    • Joner, M.1    Finn, A.V.2    Farb, A.3
  • 27
    • 65549161443 scopus 로고    scopus 로고
    • One step forward and two steps back with drug-eluting-stents: From preventing restenosis to causing late thrombosis and nouveau atherosclerosis
    • G. Nakazawa, M. Vorpahl, A.V. Finn, J. Narula, R. Virmani One step forward and two steps back with drug-eluting-stents: from preventing restenosis to causing late thrombosis and nouveau atherosclerosis J Am Coll Cardiol Img 2 2009 625 628
    • (2009) J Am Coll Cardiol Img , vol.2 , pp. 625-628
    • Nakazawa, G.1    Vorpahl, M.2    Finn, A.V.3    Narula, J.4    Virmani, R.5
  • 28
    • 79959938987 scopus 로고    scopus 로고
    • Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation
    • S.J. Kang, G.S. Mintz, T. Akasaka Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation Circulation 123 2011 2954 2963
    • (2011) Circulation , vol.123 , pp. 2954-2963
    • Kang, S.J.1    Mintz, G.S.2    Akasaka, T.3
  • 29
    • 79960338344 scopus 로고    scopus 로고
    • Pitfalls in plaque characterization by OCT: Image artifacts in native coronary arteries
    • G. van Soest, E. Regar, T.P. Goderie Pitfalls in plaque characterization by OCT: image artifacts in native coronary arteries J Am Coll Cardiol Img 4 2011 810 813
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 810-813
    • Van Soest, G.1    Regar, E.2    Goderie, T.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.