메뉴 건너뛰기




Volumn 1267, Issue , 2012, Pages 252-258

On-line capillary isotachophoresis-capillary zone electrophoresis analysis of bromate in drinking waters in an automated analyzer with coupled columns and photometric detection

Author keywords

Automated electrophoretic analyzer; Bromate; Column coupling electrophoresis; Drinking water; On line ITP sample pretreatment

Indexed keywords

AUTOMATED ELECTROPHORETIC ANALYZER; BROMATE; BUFFER SOLUTIONS; CAPILLARY ISOTACHOPHORESIS; CAPILLARY ZONE ELECTROPHORESIS; COLUMN-COUPLING ELECTROPHORESIS; CONCENTRATION LEVELS; CONDUCTIVITY DETECTORS; COUPLED COLUMN; ELECTROOSMOTIC FLOW; LIMIT OF DETECTION; MACRO-CONSTITUENTS; MIGRATION TIME; PEAK AREA; PHOTOMETRIC DETECTION; ROBUST ANALYTICAL METHODS; SAMPLE PREPARATION; SAMPLE PRETREATMENT; UV DETECTION; VALIDATION PARAMETERS; ZONE ELECTROPHORESIS;

EID: 84869086882     PISSN: 00219673     EISSN: 18733778     Source Type: Journal    
DOI: 10.1016/j.chroma.2012.07.075     Document Type: Article
Times cited : (18)

References (54)
  • 11
    • 0003183341 scopus 로고    scopus 로고
    • Council directive 98/83/EC of 3 November on the quality of water intended for human consumption
    • EC
    • EC Council directive 98/83/EC of 3 November on the quality of water intended for human consumption. Off. J. Eur. Commun. 1998, L330:32.
    • (1998) Off. J. Eur. Commun. , vol.L330 , pp. 32
  • 12
    • 0003771862 scopus 로고
    • World Health Organization, World Health Organization, Geneva, Switzerland
    • World Health Organization Guidelines for Drinking Water Quality 1993, World Health Organization, Geneva, Switzerland.
    • (1993) Guidelines for Drinking Water Quality
  • 14
    • 0000931409 scopus 로고    scopus 로고
    • National primary drinking water regulations: disinfectants and disinfection byproducts
    • U.S. EPA
    • U.S. EPA National primary drinking water regulations: disinfectants and disinfection byproducts. Fed. Reg. 1998, 63:69390.
    • (1998) Fed. Reg. , vol.63 , pp. 69390
  • 15
    • 0003399175 scopus 로고
    • US EPA Method 300.0: Methods for the Determination of Inorganic Substances in Environmental Samples
    • EPA-600/R-93-100, Cincinnati, OH
    • US EPA Method 300.0: Methods for the Determination of Inorganic Substances in Environmental Samples, EPA-600/R-93-100, Cincinnati, OH, 1993.
    • (1993)
  • 16
    • 0343114396 scopus 로고    scopus 로고
    • US EPA Method 300.1: Determination of Inorganic Anions in Drinking Water by Ion Chromatography
    • EPA/600/R-98/118, Cincinnati, OH
    • US EPA Method 300.1: Determination of Inorganic Anions in Drinking Water by Ion Chromatography, EPA/600/R-98/118, Cincinnati, OH, 1998.
    • (1998)
  • 17
    • 0003697783 scopus 로고    scopus 로고
    • US EPA Method 317.0: Determination of Inorganic Oxyhalide Disinfection By-products in Drinking Water Using Ion Chromatography in Drinking Water with the Addition of a Postcolumn Reagent for Trace Bromate Analysis
    • EPA 815-B-01-001, Cincinnati, OH
    • US EPA Method 317.0: Determination of Inorganic Oxyhalide Disinfection By-products in Drinking Water Using Ion Chromatography in Drinking Water with the Addition of a Postcolumn Reagent for Trace Bromate Analysis, EPA 815-B-01-001, Cincinnati, OH, 2001.
    • (2001)
  • 18
    • 84869085674 scopus 로고    scopus 로고
    • US EPA Method 326.0: Determination of Inorganic Oxyhalide Disinfection By-Products in Drinking Water Using Ion Chromatography Incorporating the Addition of a Suppresor Acidified Postcolumn Reagent for Trace Bromate Analysis
    • EPA 815-R-03-007, Cincinnati, OH
    • US EPA Method 326.0: Determination of Inorganic Oxyhalide Disinfection By-Products in Drinking Water Using Ion Chromatography Incorporating the Addition of a Suppresor Acidified Postcolumn Reagent for Trace Bromate Analysis, EPA 815-R-03-007, Cincinnati, OH, 2001.
    • (2001)
  • 19
    • 32744459023 scopus 로고    scopus 로고
    • US EPA Method 321.8: Determination of Bromate in Drinking Waters by Ion Chromatography Inductively Coupled Plasma-Mass Spectrometry, Cincinnati, OH
    • US EPA Method 321.8: Determination of Bromate in Drinking Waters by Ion Chromatography Inductively Coupled Plasma-Mass Spectrometry, Cincinnati, OH, 1997.
    • (1997)
  • 20
    • 84886009130 scopus 로고    scopus 로고
    • US EPA Method 302.0: Determination of Bromate in Drinking Water Using Two-Dimensional Ion Chromatography with Suppressed Conductivity Detection
    • EPA 815-B-09-014, Cincinnati, OH
    • US EPA Method 302.0: Determination of Bromate in Drinking Water Using Two-Dimensional Ion Chromatography with Suppressed Conductivity Detection, EPA 815-B-09-014, Cincinnati, OH, 2009.
    • (2009)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.