메뉴 건너뛰기




Volumn 136, Issue 4, 2012, Pages 633-640

An amperometric cholesterol biosensor based on epoxy resin membrane bound cholesterol oxidase

Author keywords

Cholesterol; Cholesterol biosensor; Cholesterol oxidase; Epoxy resin membrane; Serum

Indexed keywords

CHOLESTEROL; CHOLESTEROL OXIDASE; EPOXY RESIN; PLATINUM; SILVER; SILVER CHLORIDE;

EID: 84869076416     PISSN: 09715916     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (18)
  • 1
    • 84868116677 scopus 로고    scopus 로고
    • Association between metabolic components and subclinical atherosclerosis in Korean adults
    • Suh S-Y, Seo A-R, Ahn HY, Yim E. Association between metabolic components and subclinical atherosclerosis in Korean adults. Korean J Fam Med 2012; 33: 229-36.
    • (2012) Korean J Fam Med , vol.33 , pp. 229-236
    • Suh, S-Y.1    Seo, A-R.2    Ahn, H.Y.3    Yim, E.4
  • 2
    • 0000832469 scopus 로고
    • Amperometric determination of total cholesterol in serum with use of immobilized cholesterol esterase and cholesterol oxidase
    • Karube I, Hera K, Matsuoka H, Suzuki S. Amperometric determination of total cholesterol in serum with use of immobilized cholesterol esterase and cholesterol oxidase. Anal Chim Acta 1982; 139: 127-32.
    • (1982) Anal Chim Acta , vol.139 , pp. 127-132
    • Karube, I.1    Hera, K.2    Matsuoka, H.3    Suzuki, S.4
  • 3
    • 0035804102 scopus 로고    scopus 로고
    • Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane
    • Sean B, Dyer NS, Anthony G. Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane Anal Chm Acta 2001; 448: 27-36.
    • (2001) Anal Chm Acta , vol.448 , pp. 27-36
    • Sean, B.1    Dyer, N.S.2    Anthony, G.3
  • 4
    • 4544254548 scopus 로고    scopus 로고
    • Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-blue layers helped with self-assembled monolayers
    • Vidal JC, Espuelas J, Garica-Ruiz E, castillo JR. Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-blue layers helped with self-assembled monolayers. Talanta 2004; 64: 655-64.
    • (2004) Talanta , vol.64 , pp. 655-664
    • Vidal, J.C.1    Espuelas, J.2    Garica-Ruiz, E.3    Castillo, J.R.4
  • 5
    • 11844266646 scopus 로고    scopus 로고
    • An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film
    • Ftan X, Li M, cai P, Luo L, Zou X. An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film. Anal Biochem 2005; 337: 111-20.
    • (2005) Anal Biochem , vol.337 , pp. 111-120
    • Ftan, X.1    Li, M.2    Cai, P.3    Luo, L.4    Zou, X.5
  • 6
    • 33749005079 scopus 로고    scopus 로고
    • Comparison of effective working electrode area on planar and porous silicon substrates for cholesterol biosensor
    • Song MJ, Yun DH, Jin JH, Min NK, Hong S. comparison of effective working electrode area on planar and porous silicon substrates for cholesterol biosensor. Jap J App Phy 2006; 45: 7197-202.
    • (2006) Jap J App Phy , vol.45 , pp. 7197-7202
    • Song, M.J.1    Yun, D.H.2    Jin, J.H.3    Min, N.K.4    Hong, S.5
  • 7
    • 33646557629 scopus 로고    scopus 로고
    • Covalent immobilization of cholesterol esterase and cholesterol oxidase on polyaniline films for application to cholesterol biosensor
    • Singh S, Solanki PR, Malhotra BD. Covalent immobilization of cholesterol esterase and cholesterol oxidase on polyaniline films for application to cholesterol biosensor. Anal Chim Acta 2006; 568: 126-32.
    • (2006) Anal Chim Acta , vol.568 , pp. 126-132
    • Singh, S.1    Solanki, P.R.2    Malhotra, B.D.3
  • 8
    • 34547311324 scopus 로고    scopus 로고
    • Malhotra Cholesterol biosensor based on covalently immobilized cholesterol oxidase on the Amino-Undecanethiol Self-Assembled Monolayer using Surface Plasma Resonance Technique
    • Solanki PR, Arya SK, Iwamoto NY, Malhotra Cholesterol biosensor based on covalently immobilized cholesterol oxidase on the Amino-Undecanethiol Self-Assembled Monolayer using Surface Plasma Resonance Technique. Langmuir 2007; 1021: 7398-403.
    • (2007) Langmuir , vol.1021 , pp. 7398-7403
    • Solanki, P.R.1    Arya, S.K.2    Iwamoto, N.Y.3
  • 9
    • 55449125087 scopus 로고    scopus 로고
    • Preparation of Pt based amperometric cholesterol biosensor using cellulose acetate membrane
    • Hooda V, Pundir CS. Preparation of Pt based amperometric cholesterol biosensor using cellulose acetate membrane. J Scient Indust Res 2008; 67: 299-306.
    • (2008) J Scient Indust Res , vol.67 , pp. 299-306
    • Hooda, V.1    Pundir, C.S.2
  • 10
    • 58249128568 scopus 로고    scopus 로고
    • Biosensor based on enzyme coupled PVC reaction cell for electrochemical measurement of serum total cholesterol
    • Gahlaut A, Kumar H, Pundir CS. Biosensor based on enzyme coupled PVC reaction cell for electrochemical measurement of serum total cholesterol Sens Actuats B Chem 2009; 136: 235-41.
    • (2009) Sens Actuats B Chem , vol.136 , pp. 235-241
    • Gahlaut, A.1    Kumar, H.2    Pundir, C.S.3
  • 11
    • 46149102221 scopus 로고    scopus 로고
    • Screen-printed electrodes based on carbon nanotubes and cytochrome P450scc for highly-sensitive cholesterol biosensors
    • Carrara S, Shumyantseva V, Alexander I, Archakov, Samorì B. Screen-printed electrodes based on carbon nanotubes and cytochrome P450scc for highly-sensitive cholesterol biosensors. Biosens Bioelect 2008; 24: 148-50.
    • (2008) Biosens Bioelect , vol.24 , pp. 148-150
    • Carrara, S.1    Shumyantseva, V.2    Alexander, I.3    Archakov4    Samorì, B.5
  • 12
    • 34748920018 scopus 로고    scopus 로고
    • Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor
    • Arya SK, Pandey P, Singh SP, Datta M, Malhotra BD. Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor. Analyst 2007; 132: 1005-9.
    • (2007) Analyst , vol.132 , pp. 1005-1009
    • Arya, S.K.1    Pandey, P.2    Singh, S.P.3    Datta, M.4    Malhotra, B.D.5
  • 13
    • 75149181338 scopus 로고    scopus 로고
    • Highly sensitive amperometric cholesterol biosensor based on Pt-incorporated fullerene-like ZnO nanospheres
    • Ahmad M, Caofeng P, Lin G, Zeeshan N, Jing Z. Highly sensitive amperometric cholesterol biosensor based on Pt-incorporated fullerene-like ZnO nanospheres. J Phys Chem C 2010; 114: 243-50.
    • (2010) J Phys Chem C , vol.114 , pp. 243-250
    • Ahmad, M.1    Caofeng, P.2    Lin, G.3    Zeeshan, N.4    Jing, Z.5
  • 14
    • 60349127412 scopus 로고    scopus 로고
    • Poly(pyrrole) versus poly(3,4-ethylenedioxythiophene):Amperometric cholesterol biosensor matrices
    • Htürkarslan O, Kayahan SK, toppare L. Poly(pyrrole) versus poly(3,4-ethylenedioxythiophene):amperometric cholesterol biosensor matrices. J Solid State Electrochem 2009; 13: 657-63.
    • (2009) J Solid State Electrochem , vol.13 , pp. 657-663
    • Htürkarslan, O.1    Kayahan, S.K.2    Toppare, L.3
  • 15
    • 54249161324 scopus 로고    scopus 로고
    • Polyaniline-carbon nanotube composite film for cholesterol biosensor
    • Dhand c, Arya SK, Datta M, Malhotra bD. Polyaniline-carbon nanotube composite film for cholesterol biosensor. Anal Biochem 2008; 83: 194-9.
    • (2008) Anal Biochem , vol.83 , pp. 194-199
    • Dhand, C.1    Arya, S.K.2    Datta, M.3    Malhotrab, D.4
  • 16
    • 84869061110 scopus 로고    scopus 로고
    • Amperometric determination of serum cholesterol with pencil graphite rod
    • Chauhan N, Narang J, Pundir CS. Amperometric determination of serum cholesterol with pencil graphite rod. Am J Anal Chem 2010; 2: 41-6.
    • (2010) Am J Anal Chem , vol.2 , pp. 41-46
    • Chauhan, N.1    Narang, J.2    Pundir, C.S.3
  • 17
    • 67649640015 scopus 로고    scopus 로고
    • Fabrication of dissolved O2 metric uric acid biosensor using uricase epoxy resin biocomposite membrane
    • Arora J, Nandwani S, bhambi M, Pundir cS. Fabrication of dissolved O2 metric uric acid biosensor using uricase epoxy resin biocomposite membrane. Anal Chim Acta 2009; 647: 195-201.
    • (2009) Anal Chim Acta , vol.647 , pp. 195-201
    • Arora, J.1    Nandwani, S.2    Bhambi, M.3    Pundirc, S.4
  • 18
    • 84887618311 scopus 로고    scopus 로고
    • Construction of an amperometric ascorbate biosensor using epoxy resin membrane bound Lagenaria siceraria fruit ascorbate oxidase, Artif Cells
    • Pundir CS, Chauhan N, Jyoti. Construction of an amperometric ascorbate biosensor using epoxy resin membrane bound Lagenaria siceraria fruit ascorbate oxidase, Artif Cells, Blood Sub Biotech 2010; 10: 219-23.
    • (2010) Blood Sub Biotech , vol.10 , pp. 219-223
    • Pundir, C.S.1    Chauhan, N.2    Jyoti3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.