메뉴 건너뛰기




Volumn , Issue , 2011, Pages 2134-2137

Dual sided automated ultrasound system in the mammographic geometry

Author keywords

biomedical instrumentation; breast imaging; image processing; ultrasound

Indexed keywords

ACOUSTIC COUPLING; ATTENUATION CORRECTION; BIOMEDICAL INSTRUMENTATION; BREAST IMAGING; BREAST SCREENING; IMAGE VOLUME; MAMMOGRAPHIC; SIMPLE METHOD; ULTRASOUND SYSTEM; ULTRASOUND TRANSDUCERS; ULTRASOUND WAVES; VISUAL COMPARISON;

EID: 84869067809     PISSN: 19485719     EISSN: 19485727     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2011.0529     Document Type: Conference Paper
Times cited : (11)

References (12)
  • 1
    • 84869044125 scopus 로고    scopus 로고
    • Combined Pulse Echo, X-ray Tomosynthetic, Photoacoustic and Speed of Sound Imaging in the Mammographic Geometry
    • Procs. AIUM Annual Meeting, New York City
    • Carson P. "Combined Pulse Echo, X-ray Tomosynthetic, Photoacoustic and Speed of Sound Imaging in the Mammographic Geometry," in Procs. AIUM Annual Meeting, J Ultra Med, 30, S49, New York City, 2011. http://www.aapm.org/ meetings/2011AM/PRAbs.asp?mid=59&aid=17282.
    • (2011) J Ultra Med , vol.30
    • Carson, P.1
  • 5
    • 37049038616 scopus 로고    scopus 로고
    • Characterization of cysts using differential correlation coefficient values from two dimensional breast elastography: Preliminary study
    • PMC2330278
    • Booi RC, Carson PL, O'Donnell M, Roubidoux MA, Hall AL, Rubin JM, "Characterization of cysts using differential correlation coefficient values from two dimensional breast elastography: preliminary study," Ultrasound Med. Biol. 34(1), 12-21, PMC2330278, (2008). http://www.ncbi.nlm.nih. gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list- uids=17900795.
    • (2008) Ultrasound Med. Biol. , vol.34 , Issue.1 , pp. 12-21
    • Booi, R.C.1    Carson, P.L.2    O'Donnell, M.3    Roubidoux, Ma.4    Hall, A.L.5    Rubin, J.M.6
  • 8
    • 73049112893 scopus 로고    scopus 로고
    • New Compression Paddle for Wire Localization in Mammography
    • Blane CE, Goodsitt MM, Grimm JC, Pavlik J, March D, Ong JT, Blacklaw L, Helvie MA, "New Compression Paddle for Wire Localization in Mammography," Acad. Radiol. 17(2), 142-145, (2010). http://www.scopus.com/ inward/record.url?eid=2-s2.0-73049112893&partnerID=40&md5= e75a48432f8d625954a33a55841da5b2.
    • (2010) Acad. Radiol. , vol.17 , Issue.2 , pp. 142-145
    • Blane, C.E.1    Goodsitt, M.M.2    Grimm, J.C.3    Pavlik, J.4    March, D.5    Ong, J.T.6    Blacklaw, L.7    Helvie, M.A.8
  • 10
    • 84869031989 scopus 로고    scopus 로고
    • Combined Pulse Echo, X-Ray Tomosynthetic, Photoacoustic and Speed of Sound Imaging in the Mammographic Geometry
    • Number, Vancouver
    • Carson P, "Combined Pulse Echo, X-Ray Tomosynthetic, Photoacoustic and Speed of Sound Imaging in the Mammographic Geometry," AAPM Annual Meeting, Med Phys, 38, 3775, Number, Vancouver 2011). http://online.medphys.org/ resource/1/mphya6/v38/i6/p3775-s2.
    • (2011) AAPM Annual Meeting, Med Phys , vol.38 , pp. 3775
    • Carson, P.1
  • 12
    • 77954472314 scopus 로고    scopus 로고
    • Effect of a Gel Retainment Dam on Automated Ultrasound Coverage in a Dual-Modality Breast Imaging System
    • PMCID: PMC3098001, 〈Go to ISI〉://000279480400008
    • Li J, Goodsitt MM, Padilla F, Fowlkes JB, Hooi FM, Lashbrook CR, Thomenius KE, Carson PL, "Effect of a Gel Retainment Dam on Automated Ultrasound Coverage in a Dual-Modality Breast Imaging System," J. Ultrasound Med. 29(7), 1075-1081, PMCID: PMC3098001, (2010). 〈Go to ISI〉://000279480400008.
    • (2010) J. Ultrasound Med , vol.29 , Issue.7 , pp. 1075-1081
    • Li, J.1    Goodsitt, M.M.2    Padilla, F.3    Fowlkes, J.B.4    Hooi, F.M.5    Lashbrook, C.R.6    Thomenius, K.E.7    Carson, P.L.8