메뉴 건너뛰기




Volumn , Issue , 2011, Pages 927-930

In vivo microbubble cavitation imaging

Author keywords

Cavitation; Cavitation monitoring; Contrast Agents; Image guided therapy; Microbubbles; Sonothrombolysis; Stroke

Indexed keywords

CONTRAST AGENT; IMAGE GUIDED THERAPY; MICROBUBBLES; SONOTHROMBOLYSIS; STROKE;

EID: 84869053050     PISSN: 19485719     EISSN: 19485727     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2011.0227     Document Type: Conference Paper
Times cited : (3)

References (14)
  • 2
    • 1542298170 scopus 로고    scopus 로고
    • Utilization of tissue plasminogen activator for acute ischemic stroke
    • Katzan, I.L., et al. Utilization of tissue plasminogen activator for acute ischemic stroke. Arch Neurol 61(3): 346-50 (2004).
    • (2004) Arch Neurol , vol.61 , Issue.3 , pp. 346-350
    • Katzan, I.L.1
  • 3
    • 0028783948 scopus 로고
    • Tissue plasminogen activator for acute ischemic stroke
    • NINDS The National Institue of Neurological Disorders and Stroke rt-PA Stroke Study Group
    • NINDS. Tissue plasminogen activator for acute ischemic stroke. The National Institue of Neurological Disorders and Stroke rt-PA Stroke Study Group, N Engl J Med 333(24): 1581-7 (1995).
    • (1995) N Engl J Med , vol.333 , Issue.24 , pp. 1581-1587
  • 4
    • 77449126716 scopus 로고    scopus 로고
    • Safety and efficacy of ultrasound-enhanced thrombolysis: A comprehensive review and meta-analysis of randomized and nonrandomized studies
    • Tsivgoulis, G., et al. Safety and efficacy of ultrasound-enhanced thrombolysis: a comprehensive review and meta-analysis of randomized and nonrandomized studies. Stroke 41(2): 280-7 (2010).
    • (2010) Stroke , vol.41 , Issue.2 , pp. 280-287
    • Tsivgoulis, G.1
  • 5
    • 78149317618 scopus 로고    scopus 로고
    • In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice
    • Tung, Y. S., et al. In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice. Physics in medicine and biology 55: 6141-55 (2010).
    • (2010) Physics in Medicine and Biology , vol.55 , pp. 6141-6155
    • Tung, Y.S.1
  • 6
    • 69249140960 scopus 로고    scopus 로고
    • Transcranial ultrasound in clinical sonothrombolysis (TUCSON) trial
    • Molina, C. A., et al. Transcranial ultrasound in clinical sonothrombolysis (TUCSON) trial. Ann Neurol 66(1): 28-38 (2009)..
    • (2009) Ann Neurol , vol.66 , Issue.1 , pp. 28-38
    • Molina, C.A.1
  • 7
    • 20444498107 scopus 로고    scopus 로고
    • Effectiveness of lipid microbubbles and ultrasound in declotting thrombosis
    • Xie, F., et al. Effectiveness of lipid microbubbles and ultrasound in declotting thrombosis. Ultrasound Med Biol31(7): 979-85 (2005)..
    • (2005) Ultrasound Med Biol , vol.31 , Issue.7 , pp. 979-985
    • Xie, F.1
  • 8
    • 64149108807 scopus 로고    scopus 로고
    • Treatment of acute intravascular thrombi with diagnostic ultrasound and intravenous microbubbles
    • Xie, F., et al. Treatment of acute intravascular thrombi with diagnostic ultrasound and intravenous microbubbles. JACC Cardiovasc Imaging 2(4): 511-8 (2009)..
    • (2009) JACC Cardiovasc Imaging , vol.2 , Issue.4 , pp. 511-518
    • Xie, F.1
  • 9
    • 84869025921 scopus 로고    scopus 로고
    • Investigation of image-guided sonothrombolysis in a porcine acute ischemic stroke model
    • To appear in
    • Shi, W., et al. Investigation of image-guided sonothrombolysis in a porcine acute ischemic stroke model. To appear in IEEE IUS conference proceedings, Orlando, October 18-21 (2011).
    • IEEE IUS Conference Proceedings, Orlando, October 18-21 (2011)
    • Shi, W.1
  • 11
    • 43849099679 scopus 로고    scopus 로고
    • Transcranial sound field characterization
    • Holscher, T., al. Transcranial sound field characterization. Ultrasound Med Biol 34(6): 973-80 (2008).
    • (2008) Ultrasound Med Biol , vol.34 , Issue.6 , pp. 973-980
    • Holscher, T.1
  • 12
  • 14
    • 78649585152 scopus 로고    scopus 로고
    • The stripe artifact in transcranial ultrasound imaging
    • Vignon, F., et al. The stripe artifact in transcranial ultrasound imaging. J Ultrasound Med 29 (12): 1779-86 (2010)
    • (2010) J Ultrasound Med , vol.29 , Issue.12 , pp. 1779-1786
    • Vignon, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.