메뉴 건너뛰기




Volumn , Issue , 2011, Pages 389-392

A novel imaging method of coded THI using multi chirp signals

Author keywords

[No Author keywords available]

Indexed keywords

AXIAL RESOLUTIONS; CHIRP SIGNALS; CODED EXCITATION; CODED SIGNAL; CROSS CORRELATIONS; ECHO SIGNALS; FUNDAMENTAL COMPONENT; HARMONIC COMPONENTS; HIGH SNR; IMAGING METHOD; MEDICAL ULTRASOUND IMAGING; PULSE INVERSION; SIGNALTONOISE RATIO (SNR); SPECTRAL OVERLAP; TEMPORAL OVERLAP; TISSUE HARMONIC IMAGING; TISSUE MOTION; TRANSMITTED SIGNAL;

EID: 84869050473     PISSN: 19485719     EISSN: 19485727     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2011.0093     Document Type: Conference Paper
Times cited : (2)

References (10)
  • 4
    • 15844367336 scopus 로고    scopus 로고
    • Coded Excitation for Diagnostic Ultrasound: A System Developer's Perspective
    • R. Y. Chiao, & X. Hao, "Coded Excitation for Diagnostic Ultrasound: A System Developer's Perspective," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 52, 2005, pp.160-170.
    • (2005) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.52 , pp. 160-170
    • Chiao, R.Y.1    Hao, X.2
  • 5
    • 0035328090 scopus 로고    scopus 로고
    • Imaging System for Intravascular Ultrasonography Using Pulse Compression Technique
    • Z. Hu, T. Moriya, & Y. Tanahashi, "Imaging System for Intravascular Ultrasonography Using Pulse Compression Technique," Jpn. J. Appl. Phys., vol. 40, 2001, pp.3896.
    • (2001) Jpn. J. Appl. Phys. , vol.40 , pp. 3896
    • Hu, Z.1    Moriya, T.2    Tanahashi, Y.3
  • 7
    • 34547251781 scopus 로고    scopus 로고
    • Coded Excitation Methods for Ultrasound Harmonic Imaging
    • R. Arshadi, A. C. H. Yu, & R. S. C. Cobbold, "Coded Excitation Methods for Ultrasound Harmonic Imaging," Canadian Acoustics, vol. 35 No. 2 2007, pp.35-46.
    • (2007) Canadian Acoustics , vol.35 , Issue.2 , pp. 35-46
    • Arshadi, R.1    Yu, A.C.H.2    Cobbold, R.S.C.3
  • 8
    • 54949137714 scopus 로고    scopus 로고
    • 3 Single Crystal and Poly(Vinylidene Fluoride) for Harmonic Pulse Compression Imaging
    • 3 Single Crystal and Poly(Vinylidene Fluoride) for Harmonic Pulse Compression Imaging," Jpn. J. Appl. Phys., vol. 47, 2008, pp.4149-4154.
    • (2008) Jpn. J. Appl. Phys. , vol.47 , pp. 4149-4154
    • Tanabe, M.1    Okubo, K.2    Tagawa, N.3    Moriya, T.4
  • 9
    • 77949491457 scopus 로고    scopus 로고
    • Coded Excitation for Ultrasound Tissue Harmonic Imaging
    • J. Song, S. Kim, H. Sohn, T. Song & Y. M. Yoo, "Coded Excitation for Ultrasound Tissue Harmonic Imaging," Ultrasonics, vol. 50, 2010, pp.613-619.
    • (2010) Ultrasonics , vol.50 , pp. 613-619
    • Song, J.1    Kim, S.2    Sohn, H.3    Song, T.4    Yoo, Y.M.5
  • 10
    • 77956586413 scopus 로고    scopus 로고
    • Medical Ultrasound Imaging Using Pulse Compression Technique Based on Split and Merge Strategy
    • M. Tanabe, T. Yamamura, K. Okubo, & N. Tagawa, "Medical Ultrasound Imaging Using Pulse Compression Technique Based on Split and Merge Strategy," Jpn. J. Appl. Phys., vol. 49, 2010, pp.07HF15.1-07HF15.5.
    • (2010) Jpn. J. Appl. Phys. , vol.49
    • Tanabe, M.1    Yamamura, T.2    Okubo, K.3    Tagawa, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.