메뉴 건너뛰기




Volumn 6, Issue 1, 2012, Pages 115-124

Stress analysis of an endosseus dental implant by BEM and FEM

Author keywords

Alveolar nerve; BEM; Dental implant; FEM; Human mandible; Mandibular canal; Submodelling technique

Indexed keywords

ALVEOLAR NERVE; BEM; BONE-IMPLANT INTERFACES; CONSTITUTIVE MATERIAL LAW; FINITE ELEMENT METHOD FEM; HIGH FLEXIBILITY; HUMAN MANDIBLE; LATERAL LOADING CONDITIONS; LINEAR ELASTIC; LOCALISATION; MANDIBULAR BONE; OSTEOINTEGRATION; POST PROCESSING; STRESS FIELD; STRESS GRADIENT; SUB-MODELLING; SUBMODELS;

EID: 84869043508     PISSN: None     EISSN: 1874155X     Source Type: Journal    
DOI: 10.2174/1874155X01206010115     Document Type: Article
Times cited : (11)

References (22)
  • 1
    • 4644291445 scopus 로고    scopus 로고
    • Biomechanical aspects of marginal bone resorption around osteointegrated implants: Considerations based on a three - dimensional finite element analysis
    • E. Kitamura, R. Stegaroiu, S. Nomura, O. Miyakawa, "Biomechanical aspects of marginal bone resorption around osteointegrated implants: considerations based on a three - dimensional finite element analysis", Clinical Oral Implants Research, vol. 15, no. 4, pp. 401-412, 2004.
    • (2004) Clinical Oral Implants Research , vol.15 , Issue.4 , pp. 401-412
    • Kitamura, E.1    Stegaroiu, R.2    Nomura, S.3    Miyakawa, O.4
  • 2
    • 0030750912 scopus 로고    scopus 로고
    • Patient's perception of sensory disturbances of the mental nerve before and after implant surgery: A prospective study of 110 patients
    • D. Wismeijer, M.A.J. van Waas, W.K. Vermeeren, "Patient's perception of sensory disturbances of the mental nerve before and after implant surgery: a prospective study of 110 patients", British Journal of Oral and Maxillofacial Surgery, vol. 35, pp. 254-259, 1997.
    • (1997) British Journal of Oral and Maxillofacial Surgery , vol.35 , pp. 254-259
    • Wismeijer, D.1    van Waas, M.A.J.2    Vermeeren, W.K.3
  • 3
    • 0642335136 scopus 로고    scopus 로고
    • Apicoectomy of an endosseous implant to relieve paresthesia: A case report
    • D.S. Levitt, "Apicoectomy of an endosseous implant to relieve paresthesia: a case report", Implant Dentistry, vol. 12, no. 3, pp. 202-205, 2003.
    • (2003) Implant Dentistry , vol.12 , Issue.3 , pp. 202-205
    • Levitt, D.S.1
  • 4
    • 33845734722 scopus 로고    scopus 로고
    • The mental foramen and nerve: Clinical and anatomical factors related to dental implant placement: A literature review
    • G. Greenstein, D. Tarnow, "The mental foramen and nerve: Clinical and anatomical factors related to dental implant placement: a literature review", Journalof Periodontology, vol. 20, pp. 1933-1943, 2006.
    • (2006) Journalof Periodontology , vol.20 , pp. 1933-1943
    • Greenstein, G.1    Tarnow, D.2
  • 5
    • 0031916213 scopus 로고    scopus 로고
    • Indications and limitations of three-dimensional models in cranio-maxillofacial surgery
    • G. Santler, H. Karcher, C. Ruda, "Indications and limitations of three-dimensional models in cranio-maxillofacial surgery", Journal of Cranio-Maxillofacial Surgery, vol. 26, pp. 11-16, 1998.
    • (1998) Journal of Cranio-Maxillofacial Surgery , vol.26 , pp. 11-16
    • Santler, G.1    Karcher, H.2    Ruda, C.3
  • 6
    • 0035296232 scopus 로고    scopus 로고
    • Predictable single tooth peri-implant aesthetics: Five diagnostic keys
    • J.C. Kois, "Predictable single tooth peri-implant aesthetics: five diagnostic keys", Compendium of Continuing Education in Dentistry, vol. 22, pp. 199-206, 2001.
    • (2001) Compendium of Continuing Education In Dentistry , vol.22 , pp. 199-206
    • Kois, J.C.1
  • 8
    • 51249120726 scopus 로고    scopus 로고
    • Analysis of the occlusal stress transmitted to the inferior alveolar nerve by an osseointegrated threaded implant
    • G. Sammartino, G. Marenzi, R. Citarella, R. Ciccarelli, H.-L. Wang, "Analysis of the occlusal stress transmitted to the inferior alveolar nerve by an osseointegrated threaded implant", Journal of Periodontology, vol. 79, no. 9, pp. 1735-1744, 2008.
    • (2008) Journal of Periodontology , vol.79 , Issue.9 , pp. 1735-1744
    • Sammartino, G.1    Marenzi, G.2    Citarella, R.3    Ciccarelli, R.4    Wang, H.-L.5
  • 11
    • 84863784932 scopus 로고    scopus 로고
    • Effects of thread features in osseo-integrated titanium implants using a statistics-based finite element method
    • P. Ausiello, P. Franciosa, M. Martorelli, D.C. Watts, "Effects of thread features in osseo-integrated titanium implants using a statistics-based finite element method", Dental Materials, Vol. 8, no. 8, 2012, pp. 919-927.
    • (2012) Dental Materials , vol.8 , Issue.8 , pp. 919-927
    • Ausiello, P.1    Franciosa, P.2    Martorelli, M.3    Watts, D.C.4
  • 12
    • 0019628891 scopus 로고
    • Occlusal forces during chewing and swallowing as measured by sound transmission
    • C.H. Gibbs, P.E. Mahan, H.C. Lundeen, "Occlusal forces during chewing and swallowing as measured by sound transmission", Journal of Prosthetic Dentistry, vol. 46, pp. 443-449, 1982.
    • (1982) Journal of Prosthetic Dentistry , vol.46 , pp. 443-449
    • Gibbs, C.H.1    Mahan, P.E.2    Lundeen, H.C.3
  • 13
    • 0023882786 scopus 로고
    • A three dimensional mathematical model of the human masticatory system predicting maximum possible bite forces
    • J.H. Koolstra, T.M. van Eijden, W.A. Weijs, M. Naeije, "A three dimensional mathematical model of the human masticatory system predicting maximum possible bite forces", Journal of Biomechanics, vol. 21, pp. 573-576, 1988.
    • (1988) Journal of Biomechanics , vol.21 , pp. 573-576
    • Koolstra, J.H.1    van Eijden, T.M.2    Weijs, W.A.3    Naeije, M.4
  • 14
    • 78651588747 scopus 로고    scopus 로고
    • FEM sensitivity analyses on the stress levels in a human mandible with a varying ATM modelling complexity
    • E. Armentani, F. Caputo, R. Citarella, "FEM sensitivity analyses on the stress levels in a human mandible with a varying ATM modelling complexity", The Open Mechanical Engineering Journal, vol. 4, pp. 8-15, 2010.
    • (2010) The Open Mechanical Engineering Journal , vol.4 , pp. 8-15
    • Armentani, E.1    Caputo, F.2    Citarella, R.3
  • 16
    • 33749322538 scopus 로고    scopus 로고
    • Experimental Evaluation of Physical Properties of Bone Structures
    • F.V. Antunes, C. Pereira, M.C. Gaspar, "Experimental Evaluation of Physical Properties of Bone Structures", Applied Mechanics and Materials, vol. 5-6, pp. 71-76, 2006.
    • (2006) Applied Mechanics and Materials , vol.5-6 , pp. 71-76
    • Antunes, F.V.1    Pereira, C.2    Gaspar, M.C.3
  • 17
    • 33847035218 scopus 로고    scopus 로고
    • Numerical estimation of bone density and elastic constants distribution in a human mandible
    • J.M. Reina, J.M. García-Aznar, J. Domínguez, M. Doblaré, "Numerical estimation of bone density and elastic constants distribution in a human mandible", Journal of Biomechanics, vol. 40, no. 4, pp. 828-836, 2007.
    • (2007) Journal of Biomechanics , vol.40 , Issue.4 , pp. 828-836
    • Reina, J.M.1    García-Aznar, J.M.2    Domínguez, J.3    Doblaré, M.4
  • 18
    • 0026821443 scopus 로고
    • Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants
    • A. Shirazi-Adl, M. Dammak, G. Paiement, "Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants", Journal of Biomedical Materials Research., vol. 27, pp. 167-175, 1993.
    • (1993) Journal of Biomedical Materials Research , vol.27 , pp. 167-175
    • Shirazi-Adl, A.1    Dammak, M.2    Paiement, G.3
  • 19
    • 0026976828 scopus 로고
    • Finite element stress and strain analysis of the bone surrounding a dental implant: Effect of variations in bone modulus
    • S. E. Clift, J. Fisher, C. J. Watson, "Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus", Proceedings of the Institution of Mechanical Engineers, vol. 206, pp. 233-241, 1992.
    • (1992) Proceedings of the Institution of Mechanical Engineers , vol.206 , pp. 233-241
    • Clift, S.E.1    Fisher, J.2    Watson, C.J.3
  • 20
    • 84869853930 scopus 로고
    • Dental implants inserts - A possibility to improve the stress distribution in the jaw
    • Freiburg, F.R.G
    • D. Siegele, U. Soltesz, H. Scheicher, "Dental implants inserts - A possibility to improve the stress distribution in the jaw", Fraunhofer - Institute fur Werkstoffmechanik, Freiburg, F.R.G., 1985.
    • (1985) Fraunhofer - Institute Fur Werkstoffmechanik
    • Siegele, D.1    Soltesz, U.2    Scheicher, H.3
  • 21
    • 0024782190 scopus 로고
    • Numerical investigations of the influence of implant shape on stress distribution in the jaw bone
    • D. Siegele, U. Soltész, "Numerical investigations of the influence of implant shape on stress distribution in the jaw bone", The International Journal of Oral & Maxillofacial Implants, vol. 4, no. 4, pp. 333-340, 1989.
    • (1989) The International Journal of Oral & Maxillofacial Implants , vol.4 , Issue.4 , pp. 333-340
    • Siegele, D.1    Soltész, U.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.