-
1
-
-
0024619710
-
Capillary-zone electrophoresis/fast-atom bombardment mass spectrometry: Design of an on-line coaxial continuous-flow interface
-
M. A. Moseley, L. J. Deterding, K. B. Tomer, J. W. Jorgenson,. Capillary-zone electrophoresis/fast-atom bombardment mass spectrometry: design of an on-line coaxial continuous-flow interface. Rapid Commun. Mass Spectrom. 1989, 3, 87.
-
(1989)
Rapid Commun. Mass Spectrom.
, vol.3
, pp. 87
-
-
Moseley, M.A.1
Deterding, L.J.2
Tomer, K.B.3
Jorgenson, J.W.4
-
2
-
-
0026555061
-
Comparison of liquid-junction and coaxial interfaces for capillary electrophoresis mass-spectrometry with application to compounds of concern to the aquaculture industry
-
S. Pleasance, P. Thibault, J. Kelly,. Comparison of liquid-junction and coaxial interfaces for capillary electrophoresis mass-spectrometry with application to compounds of concern to the aquaculture industry. J. Chromatogr. 1992, 591, 325.
-
(1992)
J. Chromatogr.
, vol.591
, pp. 325
-
-
Pleasance, S.1
Thibault, P.2
Kelly, J.3
-
3
-
-
33845281491
-
Online mass-spectrometric detection for capillary zone electrophoresis
-
J. A. Olivares, N. T. Nguyen, C. R. Yonker, R. D. Smith,. Online mass-spectrometric detection for capillary zone electrophoresis. Anal. Chem. 1987, 59, 1230.
-
(1987)
Anal. Chem.
, vol.59
, pp. 1230
-
-
Olivares, J.A.1
Nguyen, N.T.2
Yonker, C.R.3
Smith, R.D.4
-
4
-
-
51249111721
-
Recent applications of capillary electrophoresis-mass spectrometry (CE-MS): CE performing functions beyond separation
-
C. A. Nesbitt, H. X. Zhang, K. K. C. Yeung,. Recent applications of capillary electrophoresis-mass spectrometry (CE-MS): CE performing functions beyond separation. Anal. Chim. Acta 2008, 627, 3.
-
(2008)
Anal. Chim. Acta
, vol.627
, pp. 3
-
-
Nesbitt, C.A.1
Zhang, H.X.2
Yeung, K.K.C.3
-
5
-
-
0028351170
-
Sheathless capillary electrophoresis-electrospray ionization mass spectrometry using 10 [mu]m I.D. capillaries: Analyses of tryptic digests of cytochrome c
-
J. H. Wahl, D. C. Gale, R. D. Smith,. Sheathless capillary electrophoresis-electrospray ionization mass spectrometry using 10 [mu]m I.D. capillaries: Analyses of tryptic digests of cytochrome c. J. Chromatogr. A 1994, 659, 217.
-
(1994)
J. Chromatogr. A
, vol.659
, pp. 217
-
-
Wahl, J.H.1
Gale, D.C.2
Smith, R.D.3
-
6
-
-
14044265644
-
Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip
-
A. P. Dahlin, M. Wetterhall, G. Liljegren, S. K. Bergstrom, P. Andren, L. Nyholm, K. E. Markides, J. Bergquist,. Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip. Analyst 2005, 130, 193.
-
(2005)
Analyst
, vol.130
, pp. 193
-
-
Dahlin, A.P.1
Wetterhall, M.2
Liljegren, G.3
Bergstrom, S.K.4
Andren, P.5
Nyholm, L.6
Markides, K.E.7
Bergquist, J.8
-
7
-
-
0037108744
-
A colloidal graphite-coated emitter for sheathless capillary electrophoresis/nanoelectrospray ionization mass spectrometry
-
X. F. Zhu, S. Thiam, B. C. Valle, I. M. Warner,. A colloidal graphite-coated emitter for sheathless capillary electrophoresis/ nanoelectrospray ionization mass spectrometry. Anal. Chem. 2002, 74, 5405.
-
(2002)
Anal. Chem.
, vol.74
, pp. 5405
-
-
Zhu, X.F.1
Thiam, S.2
Valle, B.C.3
Warner, I.M.4
-
8
-
-
0035500076
-
Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated tapered fused-silica capillary with a beveled edge
-
Y. Z. Chang, Y. R. Chen, G. R. Her,. Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated tapered fused-silica capillary with a beveled edge. Anal. Chem. 2001, 73, 5083.
-
(2001)
Anal. Chem.
, vol.73
, pp. 5083
-
-
Chang, Y.Z.1
Chen, Y.R.2
Her, G.R.3
-
9
-
-
0000104674
-
Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused silica capillary
-
Y. Z. Chang, G. R. Her,. Sheathless capillary electrophoresis/ electrospray mass spectrometry using a carbon-coated fused silica capillary. Anal. Chem. 2000, 72, 626.
-
(2000)
Anal. Chem.
, vol.72
, pp. 626
-
-
Chang, Y.Z.1
Her, G.R.2
-
10
-
-
0036916875
-
A new sheathless electrospray interface for coupling of capillary electrophoresis to ion-trap mass spectrometry
-
L. Bendahl, S. H. Hansen, J. Olsen,. A new sheathless electrospray interface for coupling of capillary electrophoresis to ion-trap mass spectrometry. Rapid Commun. Mass Spectrom. 2002, 16, 2333.
-
(2002)
Rapid Commun. Mass Spectrom.
, vol.16
, pp. 2333
-
-
Bendahl, L.1
Hansen, S.H.2
Olsen, J.3
-
11
-
-
33644747762
-
Copper-coated microsprayer interface for on-line sheathless capillary electrophoresis electrospray mass spectrometry of carbohydrates
-
A. D. Zamfir, N. Dinca, E. Sisu, J. Peter-Katalinic,. Copper-coated microsprayer interface for on-line sheathless capillary electrophoresis electrospray mass spectrometry of carbohydrates. J. Sep. Sci. 2006, 29, 414.
-
(2006)
J. Sep. Sci.
, vol.29
, pp. 414
-
-
Zamfir, A.D.1
Dinca, N.2
Sisu, E.3
Peter-Katalinic, J.4
-
12
-
-
0037288371
-
A simple method for fabrication of silver-coated sheathless electrospray emitters
-
Y. R. Chen, G. R. Her,. A simple method for fabrication of silver-coated sheathless electrospray emitters. Rapid Commun. Mass Spectrom. 2003, 17, 437.
-
(2003)
Rapid Commun. Mass Spectrom.
, vol.17
, pp. 437
-
-
Chen, Y.R.1
Her, G.R.2
-
13
-
-
15944405767
-
Design and performance of a sheathless capillary electrophoresis/mass spectrometry interface by combining fused-silica capillaries with gold-coated nanoelectrospray tips
-
Z. Kele, G. Ferenc, T. Klement, G. K. Toth, T. Janaky,. Design and performance of a sheathless capillary electrophoresis/mass spectrometry interface by combining fused-silica capillaries with gold-coated nanoelectrospray tips. Rapid Commun. Mass Spectrom. 2005, 19, 881.
-
(2005)
Rapid Commun. Mass Spectrom.
, vol.19
, pp. 881
-
-
Kele, Z.1
Ferenc, G.2
Klement, T.3
Toth, G.K.4
Janaky, T.5
-
14
-
-
0038269753
-
Gold-coated fused-silica sheathless electrospray emitters based on vapor-deposited titanium adhesion layers
-
S. Nilsson, O. Klett, M. Svedberg, A. Amirkhani, L. Nyholm,. Gold-coated fused-silica sheathless electrospray emitters based on vapor-deposited titanium adhesion layers. Rapid Commun. Mass Spectrom. 2003, 17, 1535.
-
(2003)
Rapid Commun. Mass Spectrom.
, vol.17
, pp. 1535
-
-
Nilsson, S.1
Klett, O.2
Svedberg, M.3
Amirkhani, A.4
Nyholm, L.5
-
15
-
-
84986816012
-
Capillary electrophoresis electrospray-ionization ion-trap mass-spectrometry using a sheathless interface
-
R. S. Ramsey, S. A. McLuckey,. Capillary electrophoresis electrospray-ionization ion-trap mass-spectrometry using a sheathless interface. J. Microcolumn Sep. 1995, 7, 461.
-
(1995)
J. Microcolumn Sep.
, vol.7
, pp. 461
-
-
Ramsey, R.S.1
McLuckey, S.A.2
-
16
-
-
0034759998
-
A simple and robust conductive graphite coating for sheathless electrospray emitters used in capillary electrophoresis/mass spectrometry
-
S. Nilsson, M. Wetterhall, J. Bergquist, L. Nyholm, K. E. Markides,. A simple and robust conductive graphite coating for sheathless electrospray emitters used in capillary electrophoresis/mass spectrometry. Rapid Commun. Mass Spectrom. 2001, 15, 1997.
-
(2001)
Rapid Commun. Mass Spectrom.
, vol.15
, pp. 1997
-
-
Nilsson, S.1
Wetterhall, M.2
Bergquist, J.3
Nyholm, L.4
Markides, K.E.5
-
17
-
-
0028051558
-
Online time-of-flight mass-spectrometric analysis of peptides separated by capillary electrophoresis
-
L. L. Fang, R. Zhang, E. R. Williams, R. N. Zare,. Online time-of-flight mass-spectrometric analysis of peptides separated by capillary electrophoresis. Anal. Chem. 1994, 66, 3696.
-
(1994)
Anal. Chem.
, vol.66
, pp. 3696
-
-
Fang, L.L.1
Zhang, R.2
Williams, E.R.3
Zare, R.N.4
-
18
-
-
34250185717
-
Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip
-
M. Moini,. Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip. Anal. Chem. 2007, 79, 4241.
-
(2007)
Anal. Chem.
, vol.79
, pp. 4241
-
-
Moini, M.1
-
19
-
-
78449269358
-
High Capacity Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry: Coupling a Porous Sheathless Interface with Transient- Isotachophoresis
-
J.-M. Busnel, B. Schoenmaker, R. Ramautar, A. Carrasco-Pancorbo, C. Ratnayake, J. S. Feitelson, J. D. Chapman, A. M. Deelder, O. A. Mayboroda,. High Capacity Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry: Coupling a Porous Sheathless Interface with Transient-Isotachophoresis. Anal. Chem. 2010, 82, 9476.
-
(2010)
Anal. Chem.
, vol.82
, pp. 9476
-
-
Busnel, J.-M.1
Schoenmaker, B.2
Ramautar, R.3
Carrasco-Pancorbo, A.4
Ratnayake, C.5
Feitelson, J.S.6
Chapman, J.D.7
Deelder, A.M.8
Mayboroda, O.A.9
-
20
-
-
51949112165
-
Analysis of major protein-protein and protein-metal complexes of erythrocytes directly from cell lysate utilizing capillary electrophoresis mass spectrometry
-
A. Nguyen, M. Moini,. Analysis of major protein-protein and protein-metal complexes of erythrocytes directly from cell lysate utilizing capillary electrophoresis mass spectrometry. Anal. Chem. 2008, 80, 7169.
-
(2008)
Anal. Chem.
, vol.80
, pp. 7169
-
-
Nguyen, A.1
Moini, M.2
-
21
-
-
77955891883
-
Metal displacement and stoichiometry of protein-metal complexes under native conditions using capillary electrophoresis/mass spectrometry
-
M. Moini,. Metal displacement and stoichiometry of protein-metal complexes under native conditions using capillary electrophoresis/mass spectrometry. Rapid Commun. Mass Spectrom. 2010, 24, 2730.
-
(2010)
Rapid Commun. Mass Spectrom.
, vol.24
, pp. 2730
-
-
Moini, M.1
-
22
-
-
78149357330
-
Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins
-
R. Haselberg, C. K. Ratnayake, G. J. de Jong, G. W. Somsen,. Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins. J. Chromatogr. A 2010, 1217, 7605.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 7605
-
-
Haselberg, R.1
Ratnayake, C.K.2
De Jong, G.J.3
Somsen, G.W.4
-
23
-
-
70349886556
-
Folding of glycoproteins: Toward understanding the biophysics of the glycosylation code
-
D. Shental-Bechor, Y. Levy,. Folding of glycoproteins: toward understanding the biophysics of the glycosylation code. Curr. Opin. Struct. Biol. 2009, 19, 524.
-
(2009)
Curr. Opin. Struct. Biol.
, vol.19
, pp. 524
-
-
Shental-Bechor, D.1
Levy, Y.2
-
24
-
-
0035958532
-
Head-column field-amplified sample stacking in presence of siphoning - Application to capillary electrophoresis-electrospray ionization mass spectrometry of opioids in urine
-
A. B. Wey, W. Thormann,. Head-column field-amplified sample stacking in presence of siphoning-Application to capillary electrophoresis-electrospray ionization mass spectrometry of opioids in urine. J. Chromatogr. A 2001, 924, 507.
-
(2001)
J. Chromatogr. A
, vol.924
, pp. 507
-
-
Wey, A.B.1
Thormann, W.2
-
25
-
-
0026760082
-
Drug of abuse confirmation in human urine using stepwise solid-phase extraction and micellar electrokinetic capillary chromatography
-
P. Wernly, W. Thormann,. Drug of abuse confirmation in human urine using stepwise solid-phase extraction and micellar electrokinetic capillary chromatography. Anal. Chem. 1992, 64, 2155.
-
(1992)
Anal. Chem.
, vol.64
, pp. 2155
-
-
Wernly, P.1
Thormann, W.2
-
26
-
-
0035835419
-
Column-switching high-performance liquid chromatography-electrospray ionization mass spectrometry for identification of heroin metabolites in human urine
-
M. Katagi, M. Nishikawa, M. Tatsuno, A. Miki, H. Tsuchihashi,. Column-switching high-performance liquid chromatography-electrospray ionization mass spectrometry for identification of heroin metabolites in human urine. J. Chromatogr. B 2001, 751, 177.
-
(2001)
J. Chromatogr. B
, vol.751
, pp. 177
-
-
Katagi, M.1
Nishikawa, M.2
Tatsuno, M.3
Miki, A.4
Tsuchihashi, H.5
|