메뉴 건너뛰기




Volumn 186, Issue 1-2, 2012, Pages 157-160

Minor groove binder modification of widely used TaqMan probe for hepatitis E virus reduces risk of false negative real-time PCR results

Author keywords

Hepatitis E virus; HEV; Minor groove binder; Real time PCR; TaqMan probe

Indexed keywords

VIRUS RNA;

EID: 84869014115     PISSN: 01660934     EISSN: 18790984     Source Type: Journal    
DOI: 10.1016/j.jviromet.2012.07.027     Document Type: Article
Times cited : (107)

References (20)
  • 2
    • 79953882444 scopus 로고    scopus 로고
    • Standardization of hepatitis E virus (HEV) nucleic acid amplification technique-based assays: an initial study to evaluate a panel of HEV strains and investigate laboratory performance
    • HEV Collaborative Study Group
    • Baylis S.A., Hanschmann K.M., Blümel J., Nübling C.M. Standardization of hepatitis E virus (HEV) nucleic acid amplification technique-based assays: an initial study to evaluate a panel of HEV strains and investigate laboratory performance. Journal of Clinical Microbiology 2011, 49:1234-1239. HEV Collaborative Study Group.
    • (2011) Journal of Clinical Microbiology , vol.49 , pp. 1234-1239
    • Baylis, S.A.1    Hanschmann, K.M.2    Blümel, J.3    Nübling, C.M.4
  • 3
    • 77951015275 scopus 로고    scopus 로고
    • A comparison of two commercially available anti-HEV IgG kits and a re-evaluation of anti-HEV IgG seroprevalence data in developed countries
    • Bendall R., Ellis V., Ijaz S., Ali R., Dalton H. A comparison of two commercially available anti-HEV IgG kits and a re-evaluation of anti-HEV IgG seroprevalence data in developed countries. Journal of Medical Virology 2010, 82:799-805.
    • (2010) Journal of Medical Virology , vol.82 , pp. 799-805
    • Bendall, R.1    Ellis, V.2    Ijaz, S.3    Ali, R.4    Dalton, H.5
  • 5
    • 33745713015 scopus 로고    scopus 로고
    • Validation of single real-time TaqMan PCR assay for the detection and quantitation of four major genotypes of hepatitis E virus in clinical specimens
    • Enouf V., Dos Reis G., Guthmann J.P., Guerin P.J., Caron M., Marechal V., Nicand E. Validation of single real-time TaqMan PCR assay for the detection and quantitation of four major genotypes of hepatitis E virus in clinical specimens. Journal of Medical Virology 2006, 78:1076-1082.
    • (2006) Journal of Medical Virology , vol.78 , pp. 1076-1082
    • Enouf, V.1    Dos Reis, G.2    Guthmann, J.P.3    Guerin, P.J.4    Caron, M.5    Marechal, V.6    Nicand, E.7
  • 6
    • 84855211613 scopus 로고    scopus 로고
    • Quantitation of hepatitis delta virus using a single-step internally controlled real-time RT-qPCR and a full-length genomic RNA calibration standard
    • Ferns R.B., Nastouli E., Garson J.A. Quantitation of hepatitis delta virus using a single-step internally controlled real-time RT-qPCR and a full-length genomic RNA calibration standard. Journal of Virological Methods 2012, 179:189-194.
    • (2012) Journal of Virological Methods , vol.179 , pp. 189-194
    • Ferns, R.B.1    Nastouli, E.2    Garson, J.A.3
  • 7
    • 35648929940 scopus 로고    scopus 로고
    • Universal detection of hepatitis E virus by two real-time PCR assays: TaqMan and primer-probe energy transfer
    • Gyarmati P., Mohammed N., Norder H., Blomberg J., Belák S., Widén F. Universal detection of hepatitis E virus by two real-time PCR assays: TaqMan and primer-probe energy transfer. Journal of Virological Methods 2007, 146:226-235.
    • (2007) Journal of Virological Methods , vol.146 , pp. 226-235
    • Gyarmati, P.1    Mohammed, N.2    Norder, H.3    Blomberg, J.4    Belák, S.5    Widén, F.6
  • 10
    • 28844437948 scopus 로고    scopus 로고
    • A broadly reactive one-step real-time RT-PCR assay for rapid and sensitive detection of hepatitis E virus
    • Jothikumar N., Cromeans T.L., Robertson B.H., Meng X.J., Hill V.R. A broadly reactive one-step real-time RT-PCR assay for rapid and sensitive detection of hepatitis E virus. Journal of Virological Methods 2006, 131:65-71.
    • (2006) Journal of Virological Methods , vol.131 , pp. 65-71
    • Jothikumar, N.1    Cromeans, T.L.2    Robertson, B.H.3    Meng, X.J.4    Hill, V.R.5
  • 11
    • 0028965601 scopus 로고
    • Vertical transmission of hepatitis E virus
    • Khuroo M.S., Kamili S., Jameel S. Vertical transmission of hepatitis E virus. Lancet 1995, 345:1025-1026.
    • (1995) Lancet , vol.345 , pp. 1025-1026
    • Khuroo, M.S.1    Kamili, S.2    Jameel, S.3
  • 12
    • 3242810530 scopus 로고    scopus 로고
    • Hepatitis E virus infection may be transmitted through blood transfusions in an endemic area
    • Khuroo M.S., Kamili S., Yattoo G.N. Hepatitis E virus infection may be transmitted through blood transfusions in an endemic area. Journal of Gastroenterology and Hepatology 2004, 19:778-784.
    • (2004) Journal of Gastroenterology and Hepatology , vol.19 , pp. 778-784
    • Khuroo, M.S.1    Kamili, S.2    Yattoo, G.N.3
  • 14
    • 40549122323 scopus 로고    scopus 로고
    • Hepatitis E virus: molecular virology, clinical features, diagnosis, transmission, epidemiology, and prevention
    • Mushahwar I.K. Hepatitis E virus: molecular virology, clinical features, diagnosis, transmission, epidemiology, and prevention. Journal of Medical Virology 2008, 80:646-658.
    • (2008) Journal of Medical Virology , vol.80 , pp. 646-658
    • Mushahwar, I.K.1
  • 15
    • 33847643776 scopus 로고    scopus 로고
    • Quantification of mRNA using real-time RT-PCR
    • Nolan T., Hands R.E., Bustin S.A. Quantification of mRNA using real-time RT-PCR. Nature Protocols 2006, 1:1559-1582.
    • (2006) Nature Protocols , vol.1 , pp. 1559-1582
    • Nolan, T.1    Hands, R.E.2    Bustin, S.A.3
  • 19
    • 0342436692 scopus 로고    scopus 로고
    • World Health Organisation
    • Collaborative study to establish a World Health Organization International Standard for hepatitis E virus RNA for nucleic acid amplification technology (NAT)-based assays.
    • World Health Organisation, 2011. Collaborative study to establish a World Health Organization International Standard for hepatitis E virus RNA for nucleic acid amplification technology (NAT)-based assays. http://whqlibdoc.who.int/hq/2011/WHO_BS_2011.2175_eng.pdf.
    • (2011)
  • 20
    • 35549012250 scopus 로고    scopus 로고
    • Comparison of real-time fluorescent RT-PCR and conventional RT-PCR for the detection of hepatitis E virus genotypes prevalent in China
    • Zhao C., Li Z., Yan B., Harrison T.J., Guo X., Zhang F., Yin J., Yan Y., Wang Y. Comparison of real-time fluorescent RT-PCR and conventional RT-PCR for the detection of hepatitis E virus genotypes prevalent in China. Journal of Medical Virology 2007, 79:1966-1973.
    • (2007) Journal of Medical Virology , vol.79 , pp. 1966-1973
    • Zhao, C.1    Li, Z.2    Yan, B.3    Harrison, T.J.4    Guo, X.5    Zhang, F.6    Yin, J.7    Yan, Y.8    Wang, Y.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.