메뉴 건너뛰기




Volumn , Issue , 2011, Pages 1056-1059

Implementation of a smart-phone based portable Doppler flowmeter

Author keywords

Portable Ultrasound; Pulsed Wave Doppler; Smartphone

Indexed keywords

ARTERIAL BLOOD; BLOOD FLOW; BLOOD FLOW MEASUREMENT; BLOOD FLOW VELOCITY; CARDIO-VASCULAR DISEASE; COMPLEX CIRCUITS; CONTROL CIRCUITS; COUETTE FLOWS; DOPPLER; DOPPLER FLOWMETERS; DOPPLER MEASUREMENT; DOPPLER SHIFT SIGNALS; DOPPLER SIGNALS; DOPPLER ULTRASOUND; DYNAMIC MONITORING; FLOWING BLOOD; GRAPHIC DISPLAYS; HANDHELDS; IN-VITRO; IN-VIVO; MEDICAL ULTRASOUND; ON-BOARD MEMORY; PHYSIOLOGICAL SIGNALS; PORTABLE DEVICE; PORTABLE ULTRASOUND; PROGRAMMABLE TIMER; PULSED-WAVE DOPPLER; SPECTROGRAMS; ULTRASOUND SCANNERS;

EID: 84869000915     PISSN: 19485719     EISSN: 19485727     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2011.0259     Document Type: Conference Paper
Times cited : (6)

References (26)
  • 3
    • 0017727644 scopus 로고
    • Pulsed Doppler echocardiography: Principles and application
    • D. W. Baker, S. A. Rubenstein, and G. S. Lorch, "Pulsed Doppler echocardiography: principles and application," Am. J. Med., Vol.63, pp.69-80, 1977.
    • (1977) Am. J. Med. , vol.63 , pp. 69-80
    • Baker, D.W.1    Rubenstein, S.A.2    Lorch, G.S.3
  • 4
    • 31644443827 scopus 로고    scopus 로고
    • In vitro study on the assessment of blood coagulation and clot formation using Doppler ultrasound
    • C. C. Huang, S. H. Wang, and P. H. Tsui, "In vitro study on the assessment of blood coagulation and clot formation using Doppler ultrasound," Jap. J. Appl. Phys., Vol. 44, pp. 8727-8732, 2005.
    • (2005) Jap. J. Appl. Phys. , vol.44 , pp. 8727-8732
    • Huang, C.C.1    Wang, S.H.2    Tsui, P.H.3
  • 5
    • 68649094755 scopus 로고    scopus 로고
    • Cyclic variations of high-frequency ultrasonic backscattering from blood under pulsatile flow
    • C. C. Huang, "Cyclic variations of high-frequency ultrasonic backscattering from blood under pulsatile flow," IEEE Trans Ultrason. Ferroelec. Freq. Contr., Vol. 56, pp. 1677-1688, 2009.
    • (2009) IEEE Trans Ultrason. Ferroelec. Freq. Contr. , vol.56 , pp. 1677-1688
    • Huang, C.C.1
  • 6
    • 79955533701 scopus 로고    scopus 로고
    • Detecting spatial variations of erythrocytes by ultrasound backscattering statistical parameters under pulsatile flow
    • C. C. Huang, "Detecting spatial variations of erythrocytes by ultrasound backscattering statistical parameters under pulsatile flow," IEEE Trans. Biomed. Eng., Vol. 58, pp. 1163-1171, 2011.
    • (2011) IEEE Trans. Biomed. Eng. , vol.58 , pp. 1163-1171
    • Huang, C.C.1
  • 7
    • 0026488677 scopus 로고
    • Regional cerebral artery mean flow velocity and blood flow during dynamic exercise in humans
    • L. G. Jorgensen, G. Perko, and N. H. Secher, "Regional cerebral artery mean flow velocity and blood flow during dynamic exercise in humans," J Appl. Physiol., vol. 73, pp. 1825-1830, 1992.
    • (1992) J Appl. Physiol. , vol.73 , pp. 1825-1830
    • Jorgensen, L.G.1    Perko, G.2    Secher, N.H.3
  • 8
    • 0030017310 scopus 로고    scopus 로고
    • Carotid artery blood flow and middle cerebral artery blood flow velocity during physical exercise
    • G. Hellstrom, W. Fischer-Colbrie, N. G. Wahlgren, and T. Jogestrand, "Carotid artery blood flow and middle cerebral artery blood flow velocity during physical exercise," J Appl. Physiol., Vol. 81, pp. 413-418, 1996.
    • (1996) J Appl. Physiol. , vol.81 , pp. 413-418
    • Hellstrom, G.1    Fischer-Colbrie, W.2    Wahlgren, N.G.3    Jogestrand, T.4
  • 12
    • 0030206435 scopus 로고    scopus 로고
    • Three channels telemetry system: ECG, blood velocities of the carotid and the brachial arteries
    • J. He, A. W. Pan, T. Ozaki, Y. Kinouchi, and H. Yamaguchi, "Three channels telemetry system: ECG, blood velocities of the carotid and the brachial arteries," Biomed. Eng. Appl., Basis, Commun., Vol. 8-4, pp. 364-369, 1996.
    • (1996) Biomed. Eng. Appl., Basis, Commun. , vol.8 , Issue.4 , pp. 364-369
    • He, J.1    Pan, A.W.2    Ozaki, T.3    Kinouchi, Y.4    Yamaguchi, H.5
  • 15
    • 0027993758 scopus 로고
    • Implementation of directional Doppler techniques using a digital signal processor
    • N. Aydin and D. H. Evans, "Implementation of directional Doppler techniques using a digital signal processor," Med. & Biol. Eng. & Comput., Vol. 32, pp. S157-S164, 1994.
    • (1994) Med. & Biol. Eng. & Comput. , vol.32
    • Aydin, N.1    Evans, D.H.2
  • 16
    • 0014797429 scopus 로고
    • Pulsed ultrasonic Doppler blood flow sensing
    • D. W. Baker, "Pulsed ultrasonic Doppler blood flow sensing," IEEE Trans. Sonics. and Ultrasonics., Vol. SU-17, pp.170-185, 1970
    • (1970) IEEE Trans. Sonics. and Ultrasonics. , vol.SU-17 , pp. 170-185
    • Baker, D.W.1
  • 17
    • 0016299743 scopus 로고
    • Ultrasonic pulsed Doppler system for measuring blood flow in small vessels
    • C. J. Hartley and J. S. Cole, "Ultrasonic pulsed Doppler system for measuring blood flow in small vessels," J. Appl. Physiol., Vol. 37, pp. 626-629, 1974.
    • (1974) J. Appl. Physiol. , vol.37 , pp. 626-629
    • Hartley, C.J.1    Cole, J.S.2
  • 18
    • 0016589855 scopus 로고
    • Low-power integrated circuits for an implantable pulsed Doppler ultrasonic blood flowmeter
    • R. W. Gill and J. D. Meindl, "Low-power integrated circuits for an implantable pulsed Doppler ultrasonic blood flowmeter," IEEE J. Solid-State Circuits, Vol.SC-10, pp. 464-470, 1975.
    • (1975) IEEE J. Solid-State Circuits , vol.SC-10 , pp. 464-470
    • Gill, R.W.1    Meindl, J.D.2
  • 19
    • 0017082281 scopus 로고
    • Noninvasive measurement of velocity profiles and blood flow in the common carotid artery by pulsed Doppler ultrasound
    • H. M. Keller, W.E. Meier, M. Anliker, and D. A. Kumpe, "Noninvasive measurement of velocity profiles and blood flow in the common carotid artery by pulsed Doppler ultrasound," Stroke, Vol. 7, pp. 370-377, 1976.
    • (1976) Stroke , vol.7 , pp. 370-377
    • Keller, H.M.1    Meier, W.E.2    Anliker, M.3    Kumpe, D.A.4
  • 20
    • 0018052331 scopus 로고
    • Integrated circuits for a bidirectional implantable pulsed Doppler ultrasonic blood flowmeter
    • H. V. Allen, J. W. Kutti, and J. D. Meindl, "Integrated circuits for a bidirectional implantable pulsed Doppler ultrasonic blood flowmeter," IEEE J. Solid-State Circuits, Vol. 13, pp.853-863, 1978.
    • (1978) IEEE J. Solid-State Circuits , vol.13 , pp. 853-863
    • Allen, H.V.1    Kutti, J.W.2    Meindl, J.D.3
  • 21
    • 0025500914 scopus 로고
    • The electronic detail of a pulsed Doppler blood flow measurement system
    • I. Güler and N. F. Güler, "The electronic detail of a pulsed Doppler blood flow measurement system," Meas. Sci. Technol., Vol. 1, pp. 1087-1092, 1990.
    • (1990) Meas. Sci. Technol. , vol.1 , pp. 1087-1092
    • Güler, I.1    Güler, N.F.2
  • 23
    • 48149093845 scopus 로고    scopus 로고
    • Design of a digital high frequency linear array ultrasound imaging system with high frame rate
    • C. H. Hu, K. K. Shung, and A. Chang, "Design of a digital high frequency linear array ultrasound imaging system with high frame rate," IEEE Ultrason. Symp. Proc., pp. 1529-1532, 2007.
    • (2007) IEEE Ultrason. Symp. Proc. , pp. 1529-1532
    • Hu, C.H.1    Shung, K.K.2    Chang, A.3
  • 24
    • 40949100390 scopus 로고    scopus 로고
    • High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array
    • X. Xu, L. Sun, J. M. Cannata, J. T. Yen, and K. K. Shung, "High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array," Ultrasound Med. Biol., Vol. 34, pp. 638-646, 2008.
    • (2008) Ultrasound Med. Biol. , vol.34 , pp. 638-646
    • Xu, X.1    Sun, L.2    Cannata, J.M.3    Yen, J.T.4    Shung, K.K.5
  • 25
    • 33847699414 scopus 로고    scopus 로고
    • A low-cost bipolar pulse generator for high-frequency ultrasound application
    • X. Xu, J. T. Yen, and K. K. Shung, "A low-cost bipolar pulse generator for high-frequency ultrasound application," IEEE Trans Ultrason. Ferroelec. Freq. Contr., Vol. 54, pp. 443-447, 2007.
    • (2007) IEEE Trans Ultrason. Ferroelec. Freq. Contr. , vol.54 , pp. 443-447
    • Xu, X.1    Yen, J.T.2    Shung, K.K.3
  • 26
    • 84869051056 scopus 로고    scopus 로고
    • http://www.android.com/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.