메뉴 건너뛰기




Volumn 47, Issue 1, 2012, Pages 378-387

A modified multi-ground-layer model for borehole ground heat exchangers with an inhomogeneous groundwater flow

Author keywords

Borehole; Ground heat exchanger; Ground source heat pump; Groundwater; Groundwater table

Indexed keywords

BOREHOLES; FLOW VELOCITY; GEOLOGIC MODELS; GEOTHERMAL HEAT PUMPS; GROUNDWATER FLOW; THREE DIMENSIONAL;

EID: 84868577509     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2012.09.056     Document Type: Article
Times cited : (87)

References (28)
  • 1
    • 18944387882 scopus 로고    scopus 로고
    • Ground-source heat pump system research-past, present and future
    • Spitler J.D. Ground-source heat pump system research-past, present and future. HVAC&R Research 2005, 11(2):165-167.
    • (2005) HVAC&R Research , vol.11 , Issue.2 , pp. 165-167
    • Spitler, J.D.1
  • 5
    • 0036870964 scopus 로고    scopus 로고
    • A finite line-source model for boreholes in geothermal heat exchangers
    • Zeng H.Y., Diao N.R., Fang Z.H. A finite line-source model for boreholes in geothermal heat exchangers. Heat Transfer - Asian Research 2002, 31(7):558-567.
    • (2002) Heat Transfer - Asian Research , vol.31 , Issue.7 , pp. 558-567
    • Zeng, H.Y.1    Diao, N.R.2    Fang, Z.H.3
  • 6
    • 77949917534 scopus 로고    scopus 로고
    • A new model and analytical solutions for borehole and pile ground heat exchangers
    • Man Y., Yang H., Diao N., Liu J., Fang Z. A new model and analytical solutions for borehole and pile ground heat exchangers. International Journal of Heat and Mass Transfer 2010, 53(13-14):2593-2601.
    • (2010) International Journal of Heat and Mass Transfer , vol.53 , Issue.13-14 , pp. 2593-2601
    • Man, Y.1    Yang, H.2    Diao, N.3    Liu, J.4    Fang, Z.5
  • 7
    • 0003887997 scopus 로고
    • Thermal analysis of heat extraction boreholes
    • Department of Mathematical Physics and Building Technology, University of Lund
    • Eskilson P. Thermal analysis of heat extraction boreholes, Doctoral thesis. Department of Mathematical Physics and Building Technology, University of Lund; 1987, p. 264.
    • (1987) Doctoral thesis , pp. 264
    • Eskilson, P.1
  • 8
    • 0003619510 scopus 로고
    • Ground heat storage. Thermal analysis of duct storage Systems
    • Department of Mathematical Physics, University of Lund, Sweden
    • Hellstrom G. Ground heat storage. Thermal analysis of duct storage Systems: part I theory, Doctoral thesis. Department of Mathematical Physics, University of Lund, Sweden; 1991.
    • (1991) part I theory, Doctoral thesis
    • Hellstrom, G.1
  • 9
    • 0033309869 scopus 로고    scopus 로고
    • A short time step response model for vertical ground loop heat exchangers
    • Yavuzturk C., Spitler J.D. A short time step response model for vertical ground loop heat exchangers. ASHRAE Transactions 1999, 105(2):475-485.
    • (1999) ASHRAE Transactions , vol.105 , Issue.2 , pp. 475-485
    • Yavuzturk, C.1    Spitler, J.D.2
  • 10
    • 79957475225 scopus 로고    scopus 로고
    • Simulation of a domestic ground source heat pump system using a three-dimensional numerical borehole heat exchanger model
    • He M., Rees S., Shao L. Simulation of a domestic ground source heat pump system using a three-dimensional numerical borehole heat exchanger model. Journal of Building Performance Simulation 2011, 4(2):141-155.
    • (2011) Journal of Building Performance Simulation , vol.4 , Issue.2 , pp. 141-155
    • He, M.1    Rees, S.2    Shao, L.3
  • 11
    • 39349108931 scopus 로고    scopus 로고
    • Computer simulation of borehole ground heat exchangers for geothermal heat pump systems
    • Lee C.K., Lam H.N. Computer simulation of borehole ground heat exchangers for geothermal heat pump systems. Renewable Energy 2008, 33(6):1286-1296.
    • (2008) Renewable Energy , vol.33 , Issue.6 , pp. 1286-1296
    • Lee, C.K.1    Lam, H.N.2
  • 12
    • 4544235062 scopus 로고    scopus 로고
    • Heat transfer in ground heat exchangers with groundwater advection
    • Diao N., Li Q., Fang Z. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences 2004, 43(12):1203-1211.
    • (2004) International Journal of Thermal Sciences , vol.43 , Issue.12 , pp. 1203-1211
    • Diao, N.1    Li, Q.2    Fang, Z.3
  • 13
    • 0038693752 scopus 로고    scopus 로고
    • Analytical studies of the influence of regional groundwater flow on the performance of borehole heat exchangers
    • Conference on Thermal Energy Storage, Terrastock 2000, Stuttgart, Germany
    • Claesson J, Hellstrom G. Analytical studies of the influence of regional groundwater flow on the performance of borehole heat exchangers. In: Proceedings of the 8th international Conference on Thermal Energy Storage, Terrastock 2000, Stuttgart, Germany 2000;195-200.
    • (2000) In: Proceedings of the 8th international , pp. 195-200
    • Claesson, J.1    Hellstrom, G.2
  • 15
    • 80052701931 scopus 로고    scopus 로고
    • A moving finite line source model to simulate borehole heat exchangers with groundwater advection
    • Molina-Giraldo M., Blum P., Zhu K., Bayer P., Fang Z. A moving finite line source model to simulate borehole heat exchangers with groundwater advection. International Journal of Thermal Sciences 2011, 50(12):2506-2513.
    • (2011) International Journal of Thermal Sciences , vol.50 , Issue.12 , pp. 2506-2513
    • Molina-Giraldo, M.1    Blum, P.2    Zhu, K.3    Bayer, P.4    Fang, Z.5
  • 16
    • 84861618239 scopus 로고    scopus 로고
    • New analytical solution for sizing vertical borehole ground heat exchangers in environments with significant groundwater flow: parameter estimation from thermal response test data
    • Chiasson A., O'Connell A. New analytical solution for sizing vertical borehole ground heat exchangers in environments with significant groundwater flow: parameter estimation from thermal response test data. HVAC&R Research 2011, 17(6):1000-1011.
    • (2011) HVAC&R Research , vol.17 , Issue.6 , pp. 1000-1011
    • Chiasson, A.1    O'Connell, A.2
  • 17
    • 0033725398 scopus 로고    scopus 로고
    • A preliminary assessment of the effects of groundwater flow on closed-loop ground-source heat pump systems
    • Chiasson A.D., Rees S.J., Spitler J.D. A preliminary assessment of the effects of groundwater flow on closed-loop ground-source heat pump systems. ASHRAE Transactions 2000, 106(1):380-393.
    • (2000) ASHRAE Transactions , vol.106 , Issue.1 , pp. 380-393
    • Chiasson, A.D.1    Rees, S.J.2    Spitler, J.D.3
  • 18
    • 34548512538 scopus 로고    scopus 로고
    • A study on the performance of a geothermal heat exchanger under coupled heat conduction and groundwater advection
    • Fan R., Jiang Y., Yao Y., Deng S., Ma Z. A study on the performance of a geothermal heat exchanger under coupled heat conduction and groundwater advection. Energy 2007, 32(11):2199-2209.
    • (2007) Energy , vol.32 , Issue.11 , pp. 2199-2209
    • Fan, R.1    Jiang, Y.2    Yao, Y.3    Deng, S.4    Ma, Z.5
  • 19
    • 73749084137 scopus 로고    scopus 로고
    • Computer modeling and simulation of geothermal heat pump and ground-coupled liquid desiccant air conditioning systems
    • Doctoral thesis, Department of Mechanical Engineering, University of Hong Kong
    • Lee CK. Computer modeling and simulation of geothermal heat pump and ground-coupled liquid desiccant air conditioning systems in sub-tropical regions. Doctoral thesis, Department of Mechanical Engineering, University of Hong Kong; 2008. http://hdl.handle.net/10722/51910.
    • (2008) in sub-tropical regions
    • Lee, C.K.1
  • 21
    • 29144494070 scopus 로고    scopus 로고
    • Effective thermal conductivity for single-bore vertical heat exchangers with groundwater flow
    • Barcenilla J.R., Nutter D.W., Couvillion R.J. Effective thermal conductivity for single-bore vertical heat exchangers with groundwater flow. ASHRAE Transactions 2005, 111(2):258-263.
    • (2005) ASHRAE Transactions , vol.111 , Issue.2 , pp. 258-263
    • Barcenilla, J.R.1    Nutter, D.W.2    Couvillion, R.J.3
  • 22
    • 0036459671 scopus 로고    scopus 로고
    • An algorithm for approximating the performance of vertical bore heat exchangers installed in a stratified geological regime
    • Sutton M.G., Couvillion R.J., Nutter D.W., Davis R.K. An algorithm for approximating the performance of vertical bore heat exchangers installed in a stratified geological regime. ASHRAE Transactions 2002, 108(2):177-184.
    • (2002) ASHRAE Transactions , vol.108 , Issue.2 , pp. 177-184
    • Sutton, M.G.1    Couvillion, R.J.2    Nutter, D.W.3    Davis, R.K.4
  • 23
    • 62749085637 scopus 로고    scopus 로고
    • Heat transfer analysis of underground heat exchangers in multi-soil beds
    • [in Chinese]
    • Wang Z., Yan A., Guo J. Heat transfer analysis of underground heat exchangers in multi-soil beds. Acta Energiae Solaris Sinica 2009, 30(2):188-192. [in Chinese].
    • (2009) Acta Energiae Solaris Sinica , vol.30 , Issue.2 , pp. 188-192
    • Wang, Z.1    Yan, A.2    Guo, J.3
  • 25
    • 0003678867 scopus 로고    scopus 로고
    • The Solar Energy Laboratory, University of Wisconsin-Madison, TRNSYS
    • TRNSYS A transient system simulation program 2006, The Solar Energy Laboratory, University of Wisconsin-Madison.
    • (2006) A transient system simulation program
  • 26
    • 80052259146 scopus 로고    scopus 로고
    • Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation
    • Lee C.K. Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation. Applied Energy 2011, 88(12):4405-4410.
    • (2011) Applied Energy , vol.88 , Issue.12 , pp. 4405-4410
    • Lee, C.K.1
  • 27
    • 0042830430 scopus 로고    scopus 로고
    • Heat transfer analysis of boreholes in vertical ground heat exchangers
    • Zeng H., Diao N., Fang Z. Heat transfer analysis of boreholes in vertical ground heat exchangers. International Journal of Heat and Mass Transfer 2003, 46(23):4467-4481.
    • (2003) International Journal of Heat and Mass Transfer , vol.46 , Issue.23 , pp. 4467-4481
    • Zeng, H.1    Diao, N.2    Fang, Z.3
  • 28
    • 85018007539 scopus 로고    scopus 로고
    • Effect of groundwater table on thermal response test analysis for ground-source heat pump systems
    • Conference on Applied Energy, Suzhou 2012;2141-45
    • Lee CK, Lam HN. Effect of groundwater table on thermal response test analysis for ground-source heat pump systems. In: Proceedings of the 4th International Conference on Applied Energy, Suzhou 2012;2141-45.
    • In: Proceedings of the 4th International
    • Lee, C.K.1    Lam, H.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.