메뉴 건너뛰기




Volumn 39, Issue 11, 2012, Pages 6764-6771

Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image

Author keywords

CT dose; patient dose; patient size; size specific dose estimate; water equivalent diameter

Indexed keywords

ANALYTICAL MODELS; ATOMS; COMPUTERIZED TOMOGRAPHY; CYLINDERS (SHAPES); PEDIATRICS; PHANTOMS;

EID: 84868553392     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4754303     Document Type: Article
Times cited : (72)

References (18)
  • 1
    • 79955015001 scopus 로고    scopus 로고
    • CT dose index and patient dose: They are not the same thing
    • 10.1148/radiol.11101800
    • C. H. McCollough, S. Leng, L. Yu, D. D. Cody, J. M. Boone, and M. F. McNitt-Gray, CT dose index and patient dose: They are not the same thing., Radiology 259, 311-316 (2011). 10.1148/radiol.11101800
    • (2011) Radiology , vol.259 , pp. 311-316
    • McCollough, C.H.1    Leng, S.2    Yu, L.3    Cody, D.D.4    Boone, J.M.5    McNitt-Gray, M.F.6
  • 2
    • 77950585055 scopus 로고    scopus 로고
    • The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDIvol to account for differences between scanners
    • 10.1118/1.3368596
    • A. C. Turner, M. Zankl, J. J. DeMarco, C. H. Cagnon, D. Zhang, E. Angel, D. D. Cody, D. M. Stevens, C. H. McCollough, and M. F. McNitt-Gray, The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDIvol to account for differences between scanners., Med. Phys. 37, 1816-1825 (2010). 10.1118/1.3368596
    • (2010) Med. Phys. , vol.37 , pp. 1816-1825
    • Turner, A.C.1    Zankl, M.2    Demarco, J.J.3    Cagnon, C.H.4    Zhang, D.5    Angel, E.6    Cody, D.D.7    Stevens, D.M.8    McCollough, C.H.9    McNitt-Gray, M.F.10
  • 4
    • 84862505274 scopus 로고    scopus 로고
    • American Association of Physicists in Medicine, (Task Grou204). College Park, MD, American Association of Physicists in Medicine, 2011
    • American Association of Physicists in Medicine, Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations., (Task Group 204). College Park, MD, American Association of Physicists in Medicine, 2011.
    • Size-specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations
  • 5
    • 0034037495 scopus 로고    scopus 로고
    • Effective doses to patients undergoing thoracic computed tomography examinations
    • 10.1118/1.598949
    • W. Huda, E. M. Scalzetti, and M. Roskopf, Effective doses to patients undergoing thoracic computed tomography examinations., Med. Phys. 27, 838-844 (2000). 10.1118/1.598949
    • (2000) Med. Phys. , vol.27 , pp. 838-844
    • Huda, W.1    Scalzetti, E.M.2    Roskopf, M.3
  • 6
    • 22544435185 scopus 로고    scopus 로고
    • Comparison of different body size parameters for individual dose adaptation in body CT of adults
    • 10.1148/radiol.2362041327
    • J. Menke, Comparison of different body size parameters for individual dose adaptation in body CT of adults., Radiology 236, 565-571 (2005). 10.1148/radiol.2362041327
    • (2005) Radiology , vol.236 , pp. 565-571
    • Menke, J.1
  • 7
    • 34347401255 scopus 로고    scopus 로고
    • The influence of patient centering on CT dose and image noise
    • 10.1118/1.2748113
    • T. Toth, Z. Ge, and M. P. Daly, The influence of patient centering on CT dose and image noise., Med. Phys. 34, 3093-3101 (2007). 10.1118/1.2748113
    • (2007) Med. Phys. , vol.34 , pp. 3093-3101
    • Toth, T.1    Ge, Z.2    Daly, M.P.3
  • 8
    • 78149453086 scopus 로고
    • Siemens Medical Engineering Internal Report (Siemens Medical Solutions, Forchheim, Germany)
    • K. Stierstorfer, MOCASSIM: A Monte Carlo scatter simulation tool., Siemens Medical Engineering Internal Report (Siemens Medical Solutions, Forchheim, Germany, 1993).
    • (1993) MOCASSIM: A Monte Carlo Scatter Simulation Tool
    • Stierstorfer, K.1
  • 9
    • 78149455882 scopus 로고    scopus 로고
    • Strategies for scatter correction in dual source CT
    • 10.1118/1.3504606
    • M. Petersilka, Strategies for scatter correction in dual source CT., Med. Phys. 37, 5971-5992 (2010). 10.1118/1.3504606
    • (2010) Med. Phys. , vol.37 , pp. 5971-5992
    • Petersilka, M.1
  • 11
    • 84868533600 scopus 로고    scopus 로고
    • (personal communication)
    • K. Stierstorfer (personal communication, 2011).
    • (2011)
    • Stierstorfer, K.1
  • 12
    • 0038038881 scopus 로고    scopus 로고
    • A new look at CT dose measurement: Beyond CTDI
    • 10.1118/1.1576952
    • R. L. Dixon, A new look at CT dose measurement: Beyond CTDI., Med. Phys. 30, 1272-1280 (2003). 10.1118/1.1576952
    • (2003) Med. Phys. , vol.30 , pp. 1272-1280
    • Dixon, R.L.1
  • 13
    • 70349667186 scopus 로고    scopus 로고
    • Dose spread functions in computed tomography: A Monte Carlo study
    • 10.1118/1.3223634
    • J. M. Boone, Dose spread functions in computed tomography: A Monte Carlo study., Med. Phys. 36, 4547-4554 (2009). 10.1118/1.3223634
    • (2009) Med. Phys. , vol.36 , pp. 4547-4554
    • Boone, J.M.1
  • 14
    • 0030959607 scopus 로고    scopus 로고
    • An approach for the estimation of effective radiation dose at CT in pediatric patients
    • W. Huda, J. V. Atherton, D. E. Ware, and W. A. Cumming, An approach for the estimation of effective radiation dose at CT in pediatric patients., Radiology 203, 417-422 (1997).
    • (1997) Radiology , vol.203 , pp. 417-422
    • Huda, W.1    Atherton, J.V.2    Ware, D.E.3    Cumming, W.A.4
  • 15
    • 0029029977 scopus 로고
    • CT doses in cylindrical phantoms
    • 10.1088/0031-9155/40/5/012
    • J. V. Atherton and W. Huda, CT doses in cylindrical phantoms., Phys. Med. Biol. 40, 891-911 (1995). 10.1088/0031-9155/40/5/012
    • (1995) Phys. Med. Biol. , vol.40 , pp. 891-911
    • Atherton, J.V.1    Huda, W.2
  • 16
    • 84863523468 scopus 로고    scopus 로고
    • Comparison of topogram-based body size indices for CT dose consideration and scan protocol optimization
    • 10.1118/1.4718569
    • B. Li, R. H. Behrman, and A. M. Norbash, Comparison of topogram-based body size indices for CT dose consideration and scan protocol optimization., Med. Phys. 39, 3456-3465 (2012). 10.1118/1.4718569
    • (2012) Med. Phys. , vol.39 , pp. 3456-3465
    • Li, B.1    Behrman, R.H.2    Norbash, A.M.3
  • 17
    • 13244297711 scopus 로고    scopus 로고
    • Techniques and applications of automatic tube current modulation for CT
    • 10.1148/radiol.2333031150
    • M. K. Kalra, M. M. Maher, T. L. Toth, B. Schmidt, B. L. Westerman, H. T. Morgan, and S. Saini, Techniques and applications of automatic tube current modulation for CT., Radiology 233, 649-657 (2004). 10.1148/radiol.2333031150
    • (2004) Radiology , vol.233 , pp. 649-657
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3    Schmidt, B.4    Westerman, B.L.5    Morgan, H.T.6    Saini, S.7
  • 18
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • 18. 10.1148/rg.262055138
    • C. H. McCollough, M. R. Bruesewitz, and J. M. Kofler Jr., CT dose reduction and dose management tools: Overview of available options., Radiographics 26, 503-512 (2006). 10.1148/rg.262055138
    • (2006) Radiographics , vol.26 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.