Volumn 108, Issue 3, 2012, Pages 1206-1215

Dynamic, location-based channel selection for power consumption reduction in EEG analysis

Author keywords

Channel selection; EEG; Seizure detection

Indexed keywords

AVERAGE POWER; CHANNEL SELECTION; CLASSIFICATION RESULTS; COMPUTATIONAL SAVINGS; DETECTION ACCURACY; DETECTION PERFORMANCE; EEG ANALYSIS; LOCATION BASED; NO REDUCTION; POWER CONSUMPTION REDUCTION; POWER SAVINGS; PRIMARY SCREENING; SEIZURE DETECTION;

EID: 84868532997     PISSN: 01692607     EISSN: 18727565     Source Type: Journal    
DOI: 10.1016/j.cmpb.2012.06.005     Document Type: Article
Times cited : (25)

References (24)
  • 1
    • 70349783404 scopus 로고    scopus 로고
    • How long does it take to make an accurate diagnosis in an epilepsy monitoring unit?
    • Friedman D.E., Hirsch L.J. How long does it take to make an accurate diagnosis in an epilepsy monitoring unit?. Journal of Clinical Neurophysiology 2009, 26(4):213-217. 10.1097/WNP.0b013e3181b2f2da.
    • (2009) Journal of Clinical Neurophysiology , vol.26 , Issue.4 , pp. 213-217
    • Friedman, D.E.1    Hirsch, L.J.2
  • 7
    • 84877097820 scopus 로고    scopus 로고
    • Patent application: WO2010/115939A2: a method of analysing an electroencephalogram (EEG) signal (April 2010).
    • S. Faul, A. Temko, W. Marnane, G. Lightbody, G. Boylan, Patent application: WO2010/115939A2: a method of analysing an electroencephalogram (EEG) signal (April 2010).
    • Faul, S.1    Temko, A.2    Marnane, W.3    Lightbody, G.4    Boylan, G.5
  • 8
    • 78751613317 scopus 로고    scopus 로고
    • EEG-based neonatal seizure detection with support vector machines
    • Temko A., Thomas E., Marnane W., Lightbody G., Boylan G. EEG-based neonatal seizure detection with support vector machines. Clinical Neurophysiology 2011, 122(3):464-473. 10.1016/j.clinph.2010.06.034.
    • (2011) Clinical Neurophysiology , vol.122 , Issue.3 , pp. 464-473
    • Temko, A.1    Thomas, E.2    Marnane, W.3    Lightbody, G.4    Boylan, G.5
  • 10
    • 0003243224 scopus 로고    scopus 로고
    • Probabilistic outputs for support vector machines and comparisons to regularized likelihood methods
    • MIT Press, pp. 61-74
    • Platt J.C. Probabilistic outputs for support vector machines and comparisons to regularized likelihood methods. Advances in Large Margin Classifiers 1999, MIT Press, pp. 61-74.
    • (1999) Advances in Large Margin Classifiers
    • Platt, J.C.1
  • 15
    • 78751633678 scopus 로고    scopus 로고
    • Performance assessment for EEG-based neonatal seizure detectors
    • Temko A., Thomas E., Marnane W., Lightbody G., Boylan G.B. Performance assessment for EEG-based neonatal seizure detectors. Clinical Neurophysiology 2011, 122(3):474-482. 10.1016/j.clinph.2010.06.035.
    • (2011) Clinical Neurophysiology , vol.122 , Issue.3 , pp. 474-482
    • Temko, A.1    Thomas, E.2    Marnane, W.3    Lightbody, G.4    Boylan, G.B.5
  • 16
    • 70350778433 scopus 로고    scopus 로고
    • Automated neonatal seizure detection
    • Ph.D. Thesis, University College Cork,
    • S.D. Faul, Automated neonatal seizure detection, Ph.D. Thesis, University College Cork, 2007.
    • (2007)
    • Faul, S.D.1
  • 17
    • 58149308174 scopus 로고    scopus 로고
    • Classifier models and architectures for EEG-based neonatal seizure detection
    • Greene B.R., Marnane W.P., Lightbody G., Reilly R.B., Boylan G.B. Classifier models and architectures for EEG-based neonatal seizure detection. Physiological Measurement 2008, 29(10):1157-1178. 10.1088/0967-3334/29/10/002.
    • (2008) Physiological Measurement , vol.29 , Issue.10 , pp. 1157-1178
    • Greene, B.R.1    Marnane, W.P.2    Lightbody, G.3    Reilly, R.B.4    Boylan, G.B.5
  • 18
    • 77954108725 scopus 로고    scopus 로고
    • Gaussian mixture models for classification of neonatal seizures using EEG
    • Thomas E.M., Temko A., Lightbody G., Marnane W.P., Boylan G.B. Gaussian mixture models for classification of neonatal seizures using EEG. Physiological Measurement 2010, 31(7):1047-1064. 10.1088/0967-3334/31/7/013.
    • (2010) Physiological Measurement , vol.31 , Issue.7 , pp. 1047-1064
    • Thomas, E.M.1    Temko, A.2    Lightbody, G.3    Marnane, W.P.4    Boylan, G.B.5
  • 19
    • 84877089919 scopus 로고    scopus 로고
    • University of Freiburg EEG Database,
    • University of Freiburg EEG Database, 2010. https://epilepsy.uni-freiburg.de.
    • (2010)
  • 21
    • 84877096937 scopus 로고    scopus 로고
    • Neonatal Seizures
    • (accessed 29.03.11).
    • R.D. Sheth, Neonatal Seizures, 2009. (accessed 29.03.11). http://emedicine.medscape.com/article/1177069-overview.
    • (2009)
    • Sheth, R.D.1
  • 23
    • 72649084821 scopus 로고    scopus 로고
    • Toward online data reduction for portable electroencephalography systems in epilepsy
    • Casson A.J., Rodriguez-Villegas E. Toward online data reduction for portable electroencephalography systems in epilepsy. IEEE Transactions on Biomedical Engineering 2009, 56(12):2816-2825. 10.1109/TBME.2009.2027607.
    • (2009) IEEE Transactions on Biomedical Engineering , vol.56 , Issue.12 , pp. 2816-2825
    • Casson, A.J.1    Rodriguez-Villegas, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.