-
1
-
-
36549007486
-
Computed tomography: An increasing source of radiation exposure
-
10.1056/NEJMra072149
-
D. J. Brenner and E. J. Hall, Computed tomography: An increasing source of radiation exposure., N. Engl. J. Med. 357, 2277-2284 (2007). 10.1056/NEJMra072149
-
(2007)
N. Engl. J. Med.
, vol.357
, pp. 2277-2284
-
-
Brenner, D.J.1
Hall, E.J.2
-
2
-
-
67650536250
-
-
National Council on Radiation Protection and Measurements Scientific Committee 6-2 on Radiation Exposure of the U.S. Population, NCRP Report No. 160 (National Council on Radiation Protection and Measurements, Bethesda, MD.)
-
National Council on Radiation Protection and Measurements Scientific Committee 6-2 on Radiation Exposure of the U.S. Population, Ionizing radiation exposure of the population of the United States., NCRP Report No. 160 (National Council on Radiation Protection and Measurements, Bethesda, MD., 2009).
-
(2009)
Ionizing Radiation Exposure of the Population of the United States
-
-
-
3
-
-
77953262593
-
Normalized CT dose index of the CT scanners used in the national lung screening trial
-
10.2214/AJR.09.3268
-
D. D. Cody, H. J. Kim, C. H. Cagnon, F. J. Larke, M. M. McNitt-Gray, R. L. Kruger, M. J. Flynn, J. A. Seibert, P. F. Judy, and X. Z. Wu, Normalized CT dose index of the CT scanners used in the national lung screening trial., Am. J. Roentgenol. 194, 1539-1546 (2010). 10.2214/AJR.09.3268
-
(2010)
Am. J. Roentgenol.
, vol.194
, pp. 1539-1546
-
-
Cody, D.D.1
Kim, H.J.2
Cagnon, C.H.3
Larke, F.J.4
McNitt-Gray, M.M.5
Kruger, R.L.6
Flynn, M.J.7
Seibert, J.A.8
Judy, P.F.9
Wu, X.Z.10
-
4
-
-
33750592120
-
Diagnostic reference levels in radiology
-
E. Seeram and P. C. Brennan, Diagnostic reference levels in radiology., Radiol. Technol. 77, 373-384 (2006).
-
(2006)
Radiol. Technol.
, vol.77
, pp. 373-384
-
-
Seeram, E.1
Brennan, P.C.2
-
5
-
-
70349656670
-
Radiation dose for body CT protocols: Variability of scanners at one institution
-
10.2214/AJR.09.2330
-
T. A. Jaffe, T. T. Yoshizumi, G. Toncheva, C. Anderson-Evans, C. Lowry, C. M. Miller, R. C. Nelson, and C. E. Ravin, Radiation dose for body CT protocols: Variability of scanners at one institution., AJR, Am. J. Roentgenol. 193, 1141-1147 (2009). 10.2214/AJR.09.2330
-
(2009)
AJR, Am. J. Roentgenol.
, vol.193
, pp. 1141-1147
-
-
Jaffe, T.A.1
Yoshizumi, T.T.2
Toncheva, G.3
Anderson-Evans, C.4
Lowry, C.5
Miller, C.M.6
Nelson, R.C.7
Ravin, C.E.8
-
6
-
-
77955595611
-
Radiation dose for routine clinical adult brain CT: Variability on different scanners at one institution
-
10.2214/AJR.09.3957
-
T. A. Jaffe, J. K. Hoang, T. T. Yoshizumi, G. Toncheva, C. Lowry, and C. Ravin, Radiation dose for routine clinical adult brain CT: Variability on different scanners at one institution., AJR, Am. J. Roentgenol. 195, 433-438 (2010). 10.2214/AJR.09.3957
-
(2010)
AJR, Am. J. Roentgenol.
, vol.195
, pp. 433-438
-
-
Jaffe, T.A.1
Hoang, J.K.2
Yoshizumi, T.T.3
Toncheva, G.4
Lowry, C.5
Ravin, C.6
-
7
-
-
45149100678
-
Effective dose: A useful concept in diagnostic radiology
-
10.1093/rpd/ncn056
-
D. Brenner and W. Huda, Effective dose: A useful concept in diagnostic radiology., Radiat. Prot. Dosim. 128, 503-508 (2008). 10.1093/rpd/ncn056
-
(2008)
Radiat. Prot. Dosim.
, vol.128
, pp. 503-508
-
-
Brenner, D.1
Huda, W.2
-
8
-
-
40949104442
-
The 2007 recommendations of the international commission on radiological protection. ICRP publication 103
-
ICRP, 10.1016/j.icr2007.11.001
-
ICRP, The 2007 recommendations of the international commission on radiological protection. ICRP publication 103., Ann. ICRP 37, 1-332 (2007). 10.1016/j.icrp.2007.11.001
-
(2007)
Ann. ICRP
, vol.37
, pp. 1-332
-
-
-
9
-
-
81255161356
-
RADIANCE: An automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates
-
10.1148/rg.317115048
-
T. S. Cook, S. L. Zimmerman, S. R. Steingall, A. D. Maidment, W. Kim, and W. W. Boonn, RADIANCE: An automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates., Radiographics 31, 1833-1846 (2011). 10.1148/rg.317115048
-
(2011)
Radiographics
, vol.31
, pp. 1833-1846
-
-
Cook, T.S.1
Zimmerman, S.L.2
Steingall, S.R.3
Maidment, A.D.4
Kim, W.5
Boonn, W.W.6
-
10
-
-
84928096065
-
ACR dose index registry
-
10.1016/j.jacr.2010.12.022
-
R. L. Morin, L. P. Coombs, and M. B. Chatfield, ACR dose index registry., J. Am. Coll. Radiol. 8, 288-291 (2011). 10.1016/j.jacr.2010.12.022
-
(2011)
J. Am. Coll. Radiol.
, vol.8
, pp. 288-291
-
-
Morin, R.L.1
Coombs, L.P.2
Chatfield, M.B.3
-
11
-
-
51549112607
-
-
AAPM Report No. 96 (American Association of Physicists in Medicine, College Park, MD)
-
C. McCollough, The Measurement, Reporting, and Management of Radiation Dose in CT., AAPM Report No. 96 (American Association of Physicists in Medicine, College Park, MD, 2008).
-
(2008)
The Measurement, Reporting, and Management of Radiation Dose in CT
-
-
McCollough, C.1
-
12
-
-
85027217144
-
-
AAPM Report No. (American Association of Physicists in Medicine, College Park, MD)
-
S. Boone, D. Cody, C. McCollough, M. McNitt-Gray, and T. Toth, Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations., AAPM Report No. 204 (American Association of Physicists in Medicine, College Park, MD, 2011).
-
(2011)
Size-specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations
, vol.204
-
-
Boone, S.1
Cody, D.2
McCollough, C.3
McNitt-Gray, M.4
Toth, T.5
-
13
-
-
59249102780
-
Comparison of patient size-based methods for estimating quantum noise in CT images of the lung
-
10.1118/1.3058482
-
X. Li and E. Samei, Comparison of patient size-based methods for estimating quantum noise in CT images of the lung., Med. Phys. 36, 541-546 (2009). 10.1118/1.3058482
-
(2009)
Med. Phys.
, vol.36
, pp. 541-546
-
-
Li, X.1
Samei, E.2
-
14
-
-
36849012640
-
AAPMRSNA physics tutorial for residents: Technologic advances in multidetector CT with a focus on cardiac imaging
-
10.1148/rg.276075120
-
D. D. Cody and M. Mahesh, AAPMRSNA physics tutorial for residents: Technologic advances in multidetector CT with a focus on cardiac imaging., Radiographics 27, 1829-1837 (2007). 10.1148/rg.276075120
-
(2007)
Radiographics
, vol.27
, pp. 1829-1837
-
-
Cody, D.D.1
Mahesh, M.2
-
15
-
-
27244435866
-
Is it time to retire the CTDI for CT quality assurance and dose optimization
-
10.1118/1.2040747
-
D. J. Brenner, Is it time to retire the CTDI for CT quality assurance and dose optimization, Med. Phys. 32, 3225-3226 (2005). 10.1118/1.2040747
-
(2005)
Med. Phys.
, vol.32
, pp. 3225-3226
-
-
Brenner, D.J.1
-
16
-
-
0038038881
-
A new look at CT dose measurement: Beyond CTDI
-
10.1118/1.1576952
-
R. L. Dixon, A new look at CT dose measurement: Beyond CTDI., Med. Phys. 30, 1272-1280 (2003). 10.1118/1.1576952
-
(2003)
Med. Phys.
, vol.30
, pp. 1272-1280
-
-
Dixon, R.L.1
-
17
-
-
78650876726
-
Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
-
10.1118/1.3515864
-
X. Li, E. Samei, W. P. Segars, G. M. Sturgeon, J. G. Colsher, G. Toncheva, T. T. Yoshizumi, and D. P. Frush, Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients., Med. Phys. 38, 408-419 (2011). 10.1118/1.3515864
-
(2011)
Med. Phys.
, vol.38
, pp. 408-419
-
-
Li, X.1
Samei, E.2
Segars, W.P.3
Sturgeon, G.M.4
Colsher, J.G.5
Toncheva, G.6
Yoshizumi, T.T.7
Frush, D.P.8
|