Volumn 51, Issue 1-2, 2013, Pages 723-733

Effect of nozzle geometry on heat transfer characteristics from a single circular air jet

Author keywords

Chamfered edge; Impingement heat transfer; Nusslet number; Turbulence intensity

Indexed keywords

AIR JET; AIR JET IMPINGEMENT; CHAMFERED EDGE; FLAT PLATE; HEAT TRANSFER CHARACTERISTICS; HEAT TRANSFER DISTRIBUTIONS; IMPINGEMENT HEAT TRANSFER; IMPINGEMENT SURFACES; INLET NOZZLES; LENGTH TO DIAMETER RATIO; NOZZLE CONFIGURATION; NOZZLE DIAMETER; NOZZLE GEOMETRIES; NUSSLET NUMBER; PLATE SURFACES; SEPARATION DISTANCES; SINGLE NOZZLE; TURBULENCE INTENSITY;

EID: 84868516968     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2012.09.032     Document Type: Article
Times cited : (45)

References (25)
  • 1
    • 0342700188 scopus 로고    scopus 로고
    • Effects of nozzle-inlet chamfering on pressure drop and heat transfer in confined air jet impingement
    • DOI 10.1016/S0017-9310(99)00207-0, PII S0017931099002070
    • L.A. Brignoni, and S.V. Garimella Effect of nozzle inlet chamfering on pressure and heat transfer in confined air jet impingement International Journal of Heat and Mass Transfer 43 2000 1133 1139 (Pubitemid 30170602)
    • (2000) International Journal of Heat and Mass Transfer , vol.43 , Issue.7 , pp. 1133-1139
    • Brignoni, L.A.1    Garimella, S.V.2
  • 2
    • 0027545215 scopus 로고
    • Heat transfer to impinging isothermal gas and flame jets
    • R. Viskanta Heat transfer to impinging isothermal gas and flame jets Experimental Thermal Fluid Science 6 1993 111 134 (Pubitemid 23625774)
    • (1993) Experimental Thermal and Fluid Science , vol.6 , Issue.2 , pp. 111-134
    • Viskanta, R.1
  • 3
    • 51749104039 scopus 로고
    • Single phase liquid jet impingement heat transfer
    • Academic Press San Diego
    • B.W. Webb, and C.F. Ma Single Phase Liquid Jet Impingement Heat Transfer pp. 105-217 Advanced Heat Transfer vol. 26 1995 Academic Press San Diego
    • (1995) Advanced Heat Transfer , vol.26 , pp. 105-217
    • Webb, B.W.1    Ma, C.F.2
  • 4
    • 0030199147 scopus 로고    scopus 로고
    • Effect of nozzle geometry on local convection heat transfer to a confined impinging air jet
    • D.W. Carlucci, and R. Viskanta Effect of nozzle geometry on local convection heat transfer to a confined impinging air jet Experimental Thermal Fluid Science 13 1996 71 80
    • (1996) Experimental Thermal Fluid Science , vol.13 , pp. 71-80
    • Carlucci, D.W.1    Viskanta, R.2
  • 5
    • 0037570764 scopus 로고    scopus 로고
    • Heat transfer to impinging round jets with triangular tabs
    • DOI 10.1016/S0017-9310(03)00034-6
    • N. Gao, H. Sun, and D. Ewing Heat transfer to impinging round jets with triangular tabs International Journal of Heat and Mass Transfer 46 2003 2557 2569 (Pubitemid 36610810)
    • (2003) International Journal of Heat and Mass Transfer , vol.46 , Issue.14 , pp. 2557-2569
    • Gao, N.1    Sun, H.2    Ewing, D.3
  • 6
    • 0026953120 scopus 로고
    • Effect of nozzle configuration on transport in the stagnation zone of axisymmetric, impinging free-surface liquid jets. Part 1. Turbulent flow structure
    • J. Steven, Y. Pan, and B.W. Webb Effect of nozzle configuration on transport in the stagnation zone of axisymeteric impinging free surface liquid jets part 1: turbulent flow structure International Journal of Heat and Mass Transfer 114 1992 874 879 (Pubitemid 23581923)
    • (1992) Journal of Heat Transfer , vol.114 , Issue.4 , pp. 874-879
    • Stevens, J.1    Pan, Y.2    Webb, B.W.3
  • 7
    • 0026954579 scopus 로고
    • Effect of nozzle configuration on transport in the stagnation zone of axisymmetric, impinging free-surface liquid jets. Part 2. Local heat transfer
    • J. Steven, Y. Pan, and B.W. Webb Effect of nozzle configuration on transport in the stagnation zone of axisymeteric impinging free surface liquid jets part 2: local heat transfer International Journal of Heat and Mass 114 1992 880 886 (Pubitemid 23581922)
    • (1992) Journal of Heat Transfer , vol.114 , Issue.4 , pp. 880-886
    • Pan, Y.1    Stevens, J.2    Webb, B.W.3
  • 8
    • 58149131833 scopus 로고    scopus 로고
    • Influence of the shape of the nozzle on local heat transfer distribution between smooth flat surface and impinging air jet
    • G. Puneet, K. Vadiraj, and S.V. Prabhu Influence of the shape of the nozzle on local heat transfer distribution between smooth flat surface and impinging air jet International Journal of Thermal Sciences 48 2009 602 617
    • (2009) International Journal of Thermal Sciences , vol.48 , pp. 602-617
    • Puneet, G.1    Vadiraj, K.2    Prabhu, S.V.3
  • 9
    • 10444270185 scopus 로고    scopus 로고
    • Flow characteristics and heat transfer performances of a semi-confined impinging array of jets: Effect of nozzle geometry
    • DOI 10.1016/j.ijheatmasstransfer.2004.07.046, PII S0017931004004223
    • P.E. Pertrand, A.J. Liburdy, and K. Kanokjaruvijit Flow characteristics and heat transfer performances of a semi-confined impinging array of jets: effect of nozzle geometry International Journal of Heat and Mass Transfer 48 2005 691 701 (Pubitemid 39637664)
    • (2005) International Journal of Heat and Mass Transfer , vol.48 , Issue.3-4 , pp. 691-701
    • Dano, B.P.E.1    Liburdy, J.A.2    Kanokjaruvijit, K.3
  • 11
    • 0033930917 scopus 로고    scopus 로고
    • Effect of nozzle configuration on stagnation region heat transfer enhancement of axisymmetric jet impinging
    • J. Lee, and S.J. Lee Effect of nozzle configuration on stagnation region heat transfer enhancement of axisymmetric jet impinging International Journal of Heat and Mass Transfer 43 2000 3497 3509
    • (2000) International Journal of Heat and Mass Transfer , vol.43 , pp. 3497-3509
    • Lee, J.1    Lee, S.J.2
  • 13
    • 31744436708 scopus 로고    scopus 로고
    • Effect of nozzle geometry on pressure drop and heat transfer in submerged jet arrays
    • DOI 10.1016/j.ijheatmasstransfer.2005.11.014, PII S0017931005006873
    • A. Royne, and C.J. Dey Effect of nozzle geometry on pressure drop and heat transfer in submerged jet arrays International Journal of Heat and Mass Transfer 49 2006 800 804 (Pubitemid 43177726)
    • (2006) International Journal of Heat and Mass Transfer , vol.49 , Issue.3-4 , pp. 800-804
    • Royne, A.1    Dey, C.J.2
  • 15
    • 0027628293 scopus 로고
    • Impinging jet studies for turbulence model assessment, II. An examination of four turbulence models
    • T.j. Craft, L.J. Graham, and E.B. Launder Impinging jet studies for turbulence model assessment, II. An examination of four turbulence models International Journal Heat Mass Transfer 36 1993 2685 2697
    • (1993) International Journal Heat Mass Transfer , vol.36 , pp. 2685-2697
    • Craft, T.J.1    Graham, L.J.2    Launder, E.B.3
  • 16
    • 59449106006 scopus 로고    scopus 로고
    • Heat transfer characteristics from in-line arrays of free impinging jets
    • M. Attalla, and E. Specht Heat transfer characteristics from in-line arrays of free impinging jets Heat and Mass Transfer 45 2009 537 543
    • (2009) Heat and Mass Transfer , vol.45 , pp. 537-543
    • Attalla, M.1    Specht, E.2
  • 18
    • 0002477246 scopus 로고
    • Describing uncertainties in single sample experiments
    • S.J. Kline, and F.A. McClintock Describing uncertainties in single sample experiments Mechanical Engineering 75 1953 3 8
    • (1953) Mechanical Engineering , vol.75 , pp. 3-8
    • Kline, S.J.1    McClintock, F.A.2
  • 20
    • 0030285839 scopus 로고    scopus 로고
    • Heat transfer and pressure distribution of an impinging jet on a flat surface
    • A.A. Tawfek Heat transfer and pressure distribution of an impinging jet on a flat surface International Journal Heat and Mass Transfer 32 1996 49 54
    • (1996) International Journal Heat and Mass Transfer , vol.32 , pp. 49-54
    • Tawfek, A.A.1
  • 21
    • 0345044934 scopus 로고    scopus 로고
    • The effect of nozzle aspect ratio on stagnation region heat transfer characteristic of elliptic impinging jet
    • J. Lee, and Sang-Joon Lee The effect of nozzle aspect ratio on stagnation region heat transfer characteristic of elliptic impinging jet International Journal of Heat and Mass Transfer 43 2000 555 575
    • (2000) International Journal of Heat and Mass Transfer , vol.43 , pp. 555-575
    • Lee, J.1    Lee, S.-J.2
  • 22
    • 0032648115 scopus 로고    scopus 로고
    • Stagnation region heat transfer of a turbulent axisymmetric jet impingement
    • J. Lee, and Sang-Joon Lee Stagnation region heat transfer of a turbulent axisymmetric jet impingement Experimental Heat Transfer Journal 12 1999 137 156
    • (1999) Experimental Heat Transfer Journal , vol.12 , pp. 137-156
    • Lee, J.1    Lee, S.-J.2
  • 23
    • 71749116913 scopus 로고    scopus 로고
    • Heat transfer characteristics of impinging air jet under a fixed pumping power condition
    • K.S. Choo, and S.J. Kim Heat transfer characteristics of impinging air jet under a fixed pumping power condition International Journal of Heat and Mass Transfer 53 2010 320 326
    • (2010) International Journal of Heat and Mass Transfer , vol.53 , pp. 320-326
    • Choo, K.S.1    Kim, S.J.2
  • 24
    • 2042430733 scopus 로고
    • Prediction of stagnation point heat transfer for a slot jet impinging on a flat surface
    • Kharagpur and India
    • R.K. Brahma Prediction of stagnation point heat transfer for a slot jet impinging on a flat surface Kharagpur and India Warm und Stoffübertragung 27 1992 61 66
    • (1992) Warm und Stoffübertragung , vol.27 , pp. 61-66
    • Brahma, R.K.1
  • 25
    • 0028082814 scopus 로고
    • Convective heat transfer to a confined impinging array of air jets with spent air exits
    • A.M. Huber, and R. Viskanta Convection heat transfer to a confined impinging array of air jets with spent air exit Journal of Heat Transfer, ASME 116 1994 570 576 (Pubitemid 283051)
    • (1994) Transactions - ASME: Journal of Heat Transfer , vol.116 , Issue.3 , pp. 570-576
    • Huber, A.M.1    Viskanta, R.2