메뉴 건너뛰기




Volumn 25, Issue 8, 2012, Pages 1710-1722

A wavelet-based estimating depth of anesthesia

Author keywords

Bispectral index scale (BIS); Depth of anesthesia; Electrocardiogram artifacts; Electroencephalogram (EEG); Wavelet transform (WT)

Indexed keywords

ANESTHESIA MONITORING; BISPECTRAL INDEX; BURST SUPPRESSION; COMPARISON RESULT; COMPUTATIONAL BURDEN; DEPTH OF ANESTHESIA; EEG SIGNALS; ELECTROENCEPHALOGRAM SIGNALS; ENERGY-ENTROPY; QUANTITATIVE INDICES; SINGLE-CHANNEL; STATISTICAL TOOLS; WAVELET COEFFICIENTS;

EID: 84868377291     PISSN: 09521976     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.engappai.2011.10.006     Document Type: Article
Times cited : (29)

References (46)
  • 2
    • 0001384773 scopus 로고    scopus 로고
    • Time-frequency analysis of electroencephalogram series (III): Wavelet packets and information cost function
    • S. Blanco, A. Figliola, R. Quian Quiroga, O.A. Rosso, and E. Serrano Time-frequency analysis of electroencephalogram series (III): wavelet packets and information cost function Phys. Rev. E 57 1998 932 940
    • (1998) Phys. Rev. e , vol.57 , pp. 932-940
    • Blanco, S.1    Figliola, A.2    Quian Quiroga, R.3    Rosso, O.A.4    Serrano, E.5
  • 3
    • 33748949415 scopus 로고    scopus 로고
    • Estimation of wavelet and short-time Fourier transform sonograms of normal and diabetic subjects electrogastrogram Original Research Article
    • F. Dirgenali, S. Kara, and Ş. Okkesim Estimation of wavelet and short-time Fourier transform sonograms of normal and diabetic subjects electrogastrogram Original Research Article Comput. Biol. Med. 36 2006 1289 1302
    • (2006) Comput. Biol. Med. , vol.36 , pp. 1289-1302
    • Dirgenali, F.1    Kara, S.2    Okkesim, Ş.3
  • 6
    • 33947509130 scopus 로고    scopus 로고
    • Optimal fractal-scaling analysis of human EEG dynamic for depth of anesthesia quantification
    • P. Gifani, H.R. Rabiee, M.H. Hashemi, P. Taslimi, and M. Ghanbari Optimal fractal-scaling analysis of human EEG dynamic for depth of anesthesia quantification J. Franklin Inst. 344 2007 212 229
    • (2007) J. Franklin Inst. , vol.344 , pp. 212-229
    • Gifani, P.1    Rabiee, H.R.2    Hashemi, M.H.3    Taslimi, P.4    Ghanbari, M.5
  • 7
    • 0015580754 scopus 로고
    • A simple on-line technique for removing eye movement artifacts from the EEG
    • D.G. Girton, and J. Kamiya A simple on-line technique for removing eye movement artifacts from the EEG Electroencephalogr. Clin. Neurophysiol. 34 1973 212 216
    • (1973) Electroencephalogr. Clin. Neurophysiol. , vol.34 , pp. 212-216
    • Girton, D.G.1    Kamiya, J.2
  • 10
    • 67349159110 scopus 로고    scopus 로고
    • Use of wavelet entropy to compare the EEG background activity of epileptic patients and control patients
    • Hornero, R.; Abasolo, D.E.; Espino, P.; 2003. Use of wavelet entropy to compare the EEG background activity of epileptic patients and control patients. In: Proceedings of the Seventh International Symposium, vol. 2, pp. 5-8.
    • (2003) Proceedings of the Seventh International Symposium , vol.2 , pp. 5-8
    • Hornero, R.1    Abasolo, D.E.2    Espino, P.3
  • 12
    • 0034917042 scopus 로고    scopus 로고
    • A field theory of consciousness
    • E. John A field theory of consciousness Conscious Cognit. 10 2001 184 213
    • (2001) Conscious Cognit. , vol.10 , pp. 184-213
    • John, E.1
  • 13
    • 0029826396 scopus 로고    scopus 로고
    • Autoregressive modeling with exogenous input of middle-latency auditory-evoked potentials to measure rapid changes in depth of anaesthesia
    • E.W. Jensen, P. Lindholm, and S. Henneberg Autoregressive modeling with exogenous input of middle-latency auditory-evoked potentials to measure rapid changes in depth of anaesthesia Methods Inf. Med. 35 1996 256 260
    • (1996) Methods Inf. Med. , vol.35 , pp. 256-260
    • Jensen, E.W.1    Lindholm, P.2    Henneberg, S.3
  • 14
    • 34548437097 scopus 로고    scopus 로고
    • An automatic analysis method for detecting and eliminating ECG artifacts in EEG
    • J.A. Jiang, C.F. Chao, M.J. Chiu, R.G. Lee, C.L. Tseng, and R. Lin An automatic analysis method for detecting and eliminating ECG artifacts in EEG Comput. Biol. Med. 37 2007 1660 1671
    • (2007) Comput. Biol. Med. , vol.37 , pp. 1660-1671
    • Jiang, J.A.1    Chao, C.F.2    Chiu, M.J.3    Lee, R.G.4    Tseng, C.L.5    Lin, R.6
  • 17
    • 0036326962 scopus 로고    scopus 로고
    • Comparison of conventional averaged and rapid averaged, autoregressive-based extracted auditory evoked potentials for monitoring the hypnotic level during propofol induction
    • H. Litvan, E.W. Jensen, J. Galan, J. Lund, B.E. Rodriguez, S.W. Henneberg, P. Caminal, and J.M. Villar Landeira Comparison of conventional averaged and rapid averaged, autoregressive-based extracted auditory evoked potentials for monitoring the hypnotic level during propofol induction Anesthesiology 97 2002 351 358
    • (2002) Anesthesiology , vol.97 , pp. 351-358
    • Litvan, H.1    Jensen, E.W.2    Galan, J.3    Lund, J.4    Rodriguez, B.E.5    Henneberg, S.W.6    Caminal, P.7    Villar Landeira, J.M.8
  • 18
    • 70149091472 scopus 로고    scopus 로고
    • Fractal and multifractal analysis
    • R. Lopes, and N. Betrouni Fractal and multifractal analysis Med. Image Anal. 13 2009 634 649
    • (2009) Med. Image Anal. , vol.13 , pp. 634-649
    • Lopes, R.1    Betrouni, N.2
  • 19
    • 0037369568 scopus 로고    scopus 로고
    • Changes in consciousness, conceptual memory, and quantitative electroencephalographical measures during recovery from sevoflurane and remifentanil based anesthesia
    • A. Muncaster, J. Sleigh, and M. Williams Changes in consciousness, conceptual memory, and quantitative electroencephalographical measures during recovery from sevoflurane and remifentanil based anesthesia Anesth. Analg. 96 2003 720 725
    • (2003) Anesth. Analg. , vol.96 , pp. 720-725
    • Muncaster, A.1    Sleigh, J.2    Williams, M.3
  • 20
    • 2542562742 scopus 로고    scopus 로고
    • Bispectral index monitoring to prevent awareness during anaesthesia: The B-WARE randomized controlled trial
    • P. Myles, K. Leslie, J. McNeil, A. Forbes, and M. Chan Bispectral index monitoring to prevent awareness during anaesthesia: the B-WARE randomized controlled trial Lancet 363 2004 1757 1763
    • (2004) Lancet , vol.363 , pp. 1757-1763
    • Myles, P.1    Leslie, K.2    McNeil, J.3    Forbes, A.4    Chan, M.5
  • 21
    • 33846414754 scopus 로고    scopus 로고
    • A new measure to characterize multifractality of sleep electroencephalogram
    • Q. Ma, X. Ning, J. Wang, and C. Bianl A new measure to characterize multifractality of sleep electroencephalogram Chin. Sci. Bull. 51 2006 3059
    • (2006) Chin. Sci. Bull. , vol.51 , pp. 3059
    • Ma, Q.1    Ning, X.2    Wang, J.3    Bianl, C.4
  • 22
    • 0026123844 scopus 로고
    • The multifractal nature of turbulent energy dissipation
    • C. Meneveau, and K.R. Sreenivasan The multifractal nature of turbulent energy dissipation J. Fluid Mech. 224 1991 429 484
    • (1991) J. Fluid Mech. , vol.224 , pp. 429-484
    • Meneveau, C.1    Sreenivasan, K.R.2
  • 23
    • 67549125599 scopus 로고    scopus 로고
    • Assessment of the complexity/regularity of transient brain waves (EEG) during sleep, based on wavelet theory and the concept of entropy
    • M. Mikaili, and S. Hashemi Assessment of the complexity/regularity of transient brain waves (EEG) during sleep, based on wavelet theory and the concept of entropy Iran. J. Sci. Technol. 26 2002 639 646
    • (2002) Iran. J. Sci. Technol. , vol.26 , pp. 639-646
    • Mikaili, M.1    Hashemi, S.2
  • 24
    • 74849102402 scopus 로고    scopus 로고
    • Improving the accuracy of depth of anaesthesia using modified detrended fluctuation analysis method
    • T. Nguyen-Ky, P. Wen, and Y. Li Improving the accuracy of depth of anaesthesia using modified detrended fluctuation analysis method Biomed. Signal Process. Control 5 2010 59 65
    • (2010) Biomed. Signal Process. Control , vol.5 , pp. 59-65
    • Nguyen-Ky, T.1    Wen, P.2    Li, Y.3
  • 25
    • 0023233215 scopus 로고
    • Elimination of ECG artifacts from EEG records: A new method of noncephalic referential EEG recording electroencephalogram
    • M. Nakamura, and H. Shibasaki Elimination of ECG artifacts from EEG records: a new method of noncephalic referential EEG recording electroencephalogram Clin. Neurophysiol. 66 1987 89 92
    • (1987) Clin. Neurophysiol. , vol.66 , pp. 89-92
    • Nakamura, M.1    Shibasaki, H.2
  • 26
    • 40849085158 scopus 로고    scopus 로고
    • Depth of anesthesia monitor and the frequency of intraoperative awareness
    • B.A. Orser Depth of anesthesia monitor and the frequency of intraoperative awareness N. Engl. J. Med. 358 2008 1189 1191
    • (2008) N. Engl. J. Med. , vol.358 , pp. 1189-1191
    • Orser, B.A.1
  • 27
    • 0029434863 scopus 로고
    • Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series
    • C.K. Peng, S. Havlin, H.E. Stanley, and A.L. Goldberger Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series Chaos 5 1995 827
    • (1995) Chaos , vol.5 , pp. 827
    • Peng, C.K.1    Havlin, S.2    Stanley, H.E.3    Goldberger, A.L.4
  • 28
    • 0036940591 scopus 로고    scopus 로고
    • Automated detection and elimination of periodic ECG artifacts in EEG using the energy interval histogram method
    • H.J. Park, D.U. Jeong, and K.S. Park Automated detection and elimination of periodic ECG artifacts in EEG using the energy interval histogram method IEEE Trans. Biomed. Eng. 49 2002 1526 1533
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , pp. 1526-1533
    • Park, H.J.1    Jeong, D.U.2    Park, K.S.3
  • 29
    • 0031657514 scopus 로고    scopus 로고
    • A primer for EEG signal processing in anesthesia
    • J. Rampil A primer for EEG signal processing in anesthesia Anesthesiology 89 1998 981 1001
    • (1998) Anesthesiology , vol.89 , pp. 981-1001
    • Rampil, J.1
  • 30
    • 0035216740 scopus 로고    scopus 로고
    • Bispectral index monitoring, anesthesiology clinics of North America
    • C. Rosow, and P. Manberg Bispectral index monitoring, anesthesiology clinics of North America Ann. Anesthetic Pharmacol. 19 2001 947 966
    • (2001) Ann. Anesthetic Pharmacol. , vol.19 , pp. 947-966
    • Rosow, C.1    Manberg, P.2
  • 32
    • 0037410182 scopus 로고    scopus 로고
    • Wavelet analysis of generalized tonic-clonic epileptic seizures
    • O.A. Rosso, S. Blanco, and A. Rabinowicz Wavelet analysis of generalized tonic-clonic epileptic seizures Signal Process. 83 2003 1275 1289
    • (2003) Signal Process. , vol.83 , pp. 1275-1289
    • Rosso, O.A.1    Blanco, S.2    Rabinowicz, A.3
  • 33
    • 68249141233 scopus 로고    scopus 로고
    • Relationship between depth of anesthesia and effect-site concentration of propofol during induction with the target-controlled infusion technique in elderly patients
    • L. Shao-hua, W. Wei, D. Guan-nan, K. Jing-dong, H. Fang-xiao, and T. Ming Relationship between depth of anesthesia and effect-site concentration of propofol during induction with the target-controlled infusion technique in elderly patients Chin. Med. J. 122 2009 935 940
    • (2009) Chin. Med. J. , vol.122 , pp. 935-940
    • Shao-Hua, L.1    Wei, W.2    Guan-Nan, D.3    Jing-Dong, K.4    Fang-Xiao, H.5    Ming, T.6
  • 35
    • 0001275041 scopus 로고
    • Monitoring depth of anesthesia, in anesthesia
    • R.D. Miller, Churchill Livingstone New York
    • D.R. Stanski Monitoring depth of anesthesia, in anesthesia R.D. Miller, Anesthesia 1994 Churchill Livingstone New York 1127 1159
    • (1994) Anesthesia , pp. 1127-1159
    • Stanski, D.R.1
  • 37
    • 0242332304 scopus 로고    scopus 로고
    • Narcotrend and bispectral index monitor are superior to classic electroencephalographic parameters for the assessment of anesthetic states during propofol-remifentanil anesthesia
    • G. Schmidt, P. Bischoff, T. Standl, K. Jensen, M. Voigt, and J.A.M. Schulte Esch Narcotrend and bispectral index monitor are superior to classic electroencephalographic parameters for the assessment of anesthetic states during propofol-remifentanil anesthesia Anesthesiology 99 2003 1072 1077
    • (2003) Anesthesiology , vol.99 , pp. 1072-1077
    • Schmidt, G.1    Bischoff, P.2    Standl, T.3    Jensen, K.4    Voigt, M.5    Schulte Esch, J.A.M.6
  • 39
    • 78049528154 scopus 로고    scopus 로고
    • A new approach for EEG signal classification of schizophrenic and control participants
    • M. Sabeti, S.D. Katebi, R. Boostani, and G.W. Price A new approach for EEG signal classification of schizophrenic and control participants Expert Syst. Appl. 38 2011 2063 2071
    • (2011) Expert Syst. Appl. , vol.38 , pp. 2063-2071
    • Sabeti, M.1    Katebi, S.D.2    Boostani, R.3    Price, G.W.4
  • 40
    • 33646153511 scopus 로고    scopus 로고
    • Optimal selection of wavelet basis function applied to ECG signal denoising
    • B.N. Singh, and A.K. Tiwari Optimal selection of wavelet basis function applied to ECG signal denoising Digital Signal Process. 16 2006 275 287
    • (2006) Digital Signal Process. , vol.16 , pp. 275-287
    • Singh, B.N.1    Tiwari, A.K.2
  • 41
    • 0021523445 scopus 로고
    • Estimation of QRS complex power spectra for design of a QRS filter
    • N.V. Thakor, J.G. Webster, and W.J. Tompkins Estimation of QRS complex power spectra for design of a QRS filter IEEE Trans. Biomed. Eng. 31 1984 702 705
    • (1984) IEEE Trans. Biomed. Eng. , vol.31 , pp. 702-705
    • Thakor, N.V.1    Webster, J.G.2    Tompkins, W.J.3
  • 42
    • 9944233504 scopus 로고    scopus 로고
    • Quantification of the dynamic behavior over time of narrow-band components present in heart rate variability by means of the instantaneous amplitude and frequency Original Research Article
    • H.G. van Steenis, W.L.J. Martens, and J.H.M. Tulen Quantification of the dynamic behavior over time of narrow-band components present in heart rate variability by means of the instantaneous amplitude and frequency Original Research Article Comput. Biol. Med. 35 2005 197 215
    • (2005) Comput. Biol. Med. , vol.35 , pp. 197-215
    • Van Steenis, H.G.1    Martens, W.L.J.2    Tulen, J.H.M.3
  • 44
    • 70350716318 scopus 로고    scopus 로고
    • Spatio-temporal analysis of monofractal and multifractal properties of the human sleep EEG
    • B. Weiss, Z. Clemens, R. Bódizs, Z. Vágó, and P. Halász Spatio-temporal analysis of monofractal and multifractal properties of the human sleep EEG J. Neurosci. Methods 185 2009 116
    • (2009) J. Neurosci. Methods , vol.185 , pp. 116
    • Weiss, B.1    Clemens, Z.2    Bódizs, R.3    Vágó, Z.4    Halász, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.