메뉴 건너뛰기




Volumn 105, Issue 1, 2012, Pages 127-132

Out-of-field contributions for IMRT and volumetric modulated arc therapy measured using gafchromic films and compared to calculations using a superposition/convolution based treatment planning system

Author keywords

Dosimetry; Radiation oncology; Second tumors

Indexed keywords

ARTICLE; BIOFILM; COMPUTER PROGRAM; CONTROLLED STUDY; DOSIMETRY; GAFCHROMIC FILM; HUMAN; INTENSITY MODULATED RADIATION THERAPY; MALE; NEUTRON DOSIMETRY; OPEN FIELD TEST; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; ROTATION; TREATMENT PLANNING; VOLUMETRIC MODULATED ARC THERAPY; VOLUMETRY; WHOLE BODY RADIATION;

EID: 84868376514     PISSN: 01678140     EISSN: 18790887     Source Type: Journal    
DOI: 10.1016/j.radonc.2011.12.030     Document Type: Article
Times cited : (27)

References (22)
  • 1
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • ISSN 0094-2405
    • P. Almond, P. Biggs, B. Coursey, W. Hanson, M. Huq, and R. Nath AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams Med Phys 26 1999 1847 1870 ISSN 0094-2405
    • (1999) Med Phys , vol.26 , pp. 1847-1870
    • Almond, P.1    Biggs, P.2    Coursey, B.3    Hanson, W.4    Huq, M.5    Nath, R.6
  • 2
    • 38049117854 scopus 로고    scopus 로고
    • The use of LiF (TLD-100) as an out-of-field dosimeter
    • S. Kry, M. Price, and D. Followill The use of LiF (TLD-100) as an out-of-field dosimeter J Appl Clin Med Phys 8 2007 169 175
    • (2007) J Appl Clin Med Phys , vol.8 , pp. 169-175
    • Kry, S.1    Price, M.2    Followill, D.3
  • 3
    • 70350517931 scopus 로고    scopus 로고
    • Calculated organ doses from selected prostate treatment plans using Monte Carlo simulations and an anatomically realistic computational phantom
    • B. Bednarz, C. Hancox, and X. Xu Calculated organ doses from selected prostate treatment plans using Monte Carlo simulations and an anatomically realistic computational phantom Phys Med Biol 54 2009 5271 5286
    • (2009) Phys Med Biol , vol.54 , pp. 5271-5286
    • Bednarz, B.1    Hancox, C.2    Xu, X.3
  • 4
    • 33745321145 scopus 로고    scopus 로고
    • Organ doses from prostate radiotherapy and associated concomitant exposures
    • R. Harrison, M. Wilkinson, and A. Shemil Organ doses from prostate radiotherapy and associated concomitant exposures Br J Radiol 79 2006 487 496
    • (2006) Br J Radiol , vol.79 , pp. 487-496
    • Harrison, R.1    Wilkinson, M.2    Shemil, A.3
  • 5
    • 0032761750 scopus 로고    scopus 로고
    • Risk assessment of radiation-induced malignancies based on whole-body equivalent dose estimates for IMRT treatment in the head and neck region
    • [ISSN 0167-8140]
    • D. Verellen, and F. Vanhavere Risk assessment of radiation-induced malignancies based on whole-body equivalent dose estimates for IMRT treatment in the head and neck region Radther Oncol 53 1999 199 203 [ISSN 0167-8140]
    • (1999) Radther Oncol , vol.53 , pp. 199-203
    • Verellen, D.1    Vanhavere, F.2
  • 6
    • 81755166367 scopus 로고    scopus 로고
    • The superiority of hybrid-volumetric arc therapy (VMAT) technique over double arcs VMAT and 3D-conformal technique in the treatment of locally advanced non-small cell lung cancer. A planning study
    • O.S. Chan, M.C. Lee, A.W. Hung, A.T. Chang, R.M. Yeung, and A.W. Lee The superiority of hybrid-volumetric arc therapy (VMAT) technique over double arcs VMAT and 3D-conformal technique in the treatment of locally advanced non-small cell lung cancer. A planning study Radiother Oncol 101 2011 298 302
    • (2011) Radiother Oncol , vol.101 , pp. 298-302
    • Chan, O.S.1    Lee, M.C.2    Hung, A.W.3    Chang, A.T.4    Yeung, R.M.5    Lee, A.W.6
  • 7
    • 79954592313 scopus 로고    scopus 로고
    • Cranio-spinal irradiation with volumetric modulated arc therapy: A multi-institutional treatment experience
    • A. Fogliata, S. Bergström, I. Cafaro, A. Clivio, L. Cozzi, and G. Dipasquale Cranio-spinal irradiation with volumetric modulated arc therapy: a multi-institutional treatment experience Radiother Oncol 99 2011 79 85
    • (2011) Radiother Oncol , vol.99 , pp. 79-85
    • Fogliata, A.1    Bergström, S.2    Cafaro, I.3    Clivio, A.4    Cozzi, L.5    Dipasquale, G.6
  • 8
    • 81855175342 scopus 로고    scopus 로고
    • Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT & Arc technique for esophageal carcinoma
    • S. Martin, J.Z. Chen, A.R. Dar, and S. Yartsev Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT & Arc technique for esophageal carcinoma Radiother Oncol 101 2011 431 437
    • (2011) Radiother Oncol , vol.101 , pp. 431-437
    • Martin, S.1    Chen, J.Z.2    Dar, A.R.3    Yartsev, S.4
  • 9
    • 0028850911 scopus 로고
    • Fetal dose from radiotherapy with photon beams: Report of AAPM Radiation Therapy Committee Task Group No. 36
    • M. Stovall, C.R. Blackwell, J. Cundiff, D.H. Novack, J.R. Palta, and L.K. Wagner Fetal dose from radiotherapy with photon beams: report of AAPM Radiation Therapy Committee Task Group No. 36 Med Phys 22 1995 63 82
    • (1995) Med Phys , vol.22 , pp. 63-82
    • Stovall, M.1    Blackwell, C.R.2    Cundiff, J.3    Novack, D.H.4    Palta, J.R.5    Wagner, L.K.6
  • 10
    • 84875382630 scopus 로고    scopus 로고
    • Tongue cancers during pregnancy: Case reports and review of literature
    • 10.1002/hed.21924 [n/a-n/a ISSN 1097-0347]
    • M. Mhallem Gziri, S.N. Han, K. Van Calsteren, L. Heyns, P. Delaere, and S. Nuyts Tongue cancers during pregnancy: case reports and review of literature Head Neck 2011 10.1002/hed.21924 [n/a-n/a ISSN 1097-0347, http://dx.doi.org/10. 1002/hed.21924 ]
    • (2011) Head Neck
    • Mhallem Gziri, M.1    Han, S.N.2    Van Calsteren, K.3    Heyns, L.4    Delaere, P.5    Nuyts, S.6
  • 11
    • 0035252099 scopus 로고    scopus 로고
    • Peridose a software program to calculate the dose outside the primary beam in radiation therapy
    • P. van der Giessen Peridose a software program to calculate the dose outside the primary beam in radiation therapy Radiother Oncol 58 2001 209 213
    • (2001) Radiother Oncol , vol.58 , pp. 209-213
    • Van Der Giessen, P.1
  • 15
    • 82755163870 scopus 로고    scopus 로고
    • Companding technique for high dynamic range measurements using Gafchromic films
    • F. Van den Heuvel, W. Crijns, and G. Defraene Companding technique for high dynamic range measurements using Gafchromic films Med Phys 38 2011 6443 6448
    • (2011) Med Phys , vol.38 , pp. 6443-6448
    • Van Den Heuvel, F.1    Crijns, W.2    Defraene, G.3
  • 16
    • 0032183837 scopus 로고    scopus 로고
    • A combined use of the BD-PND and BDT bubble detectors in neutron dosimetery
    • F. Vanhavere, M. Loos, A. Plompen, E. Wattecamps, and H. Thierens A combined use of the BD-PND and BDT bubble detectors in neutron dosimetery Radiat Meas 29 1998 573 577
    • (1998) Radiat Meas , vol.29 , pp. 573-577
    • Vanhavere, F.1    Loos, M.2    Plompen, A.3    Wattecamps, E.4    Thierens, H.5
  • 19
    • 78651378610 scopus 로고    scopus 로고
    • Comparison of second cancer risk due to out-of-field doses from 6-MV IMRT and proton therapy based on 6 pediatric patient treatment plans
    • B.S. Athar, and H. Paganetti Comparison of second cancer risk due to out-of-field doses from 6-MV IMRT and proton therapy based on 6 pediatric patient treatment plans Radiother Oncol 98 2011 87 92
    • (2011) Radiother Oncol , vol.98 , pp. 87-92
    • Athar, B.S.1    Paganetti, H.2
  • 20
    • 62549083410 scopus 로고    scopus 로고
    • Monte Carlo study shows no significant difference in second cancer risk between 6- and 18-MV intensity-modulated radiation therapy
    • S.F. Kry, M. Salehpour, U. Titt, R.A. White, M. Stovall, and D. Followill Monte Carlo study shows no significant difference in second cancer risk between 6- and 18-MV intensity-modulated radiation therapy Radiother Oncol 91 2009 132 137
    • (2009) Radiother Oncol , vol.91 , pp. 132-137
    • Kry, S.F.1    Salehpour, M.2    Titt, U.3    White, R.A.4    Stovall, M.5    Followill, D.6
  • 21
    • 42449124765 scopus 로고    scopus 로고
    • Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac
    • A. Ma, J. Awotwi-Pratt, and A. Alghamdi Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac J Radioanal Nucl Chem 276 2008 119 123
    • (2008) J Radioanal Nucl Chem , vol.276 , pp. 119-123
    • Ma, A.1    Awotwi-Pratt, J.2    Alghamdi, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.