메뉴 건너뛰기




Volumn 123, Issue 3, 2012, Pages 168-171

Radiation-induced eye lens changes and risk for cataract in interventional cardiology

Author keywords

Cataract risk; Cataract risk to nurse; Interventional cardiology; Lens opacity cath lab staff; Posterior subcapsular cataract (psc)

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOLOGIST; CLINICAL PRACTICE; CONTROLLED STUDY; DISEASE PREDISPOSITION; FEMALE; HUMAN; INTERVENTIONAL RADIOLOGY; MALE; NURSE; OCCUPATIONAL DISEASE; POSTERIOR LENS CAPSULE; PRIORITY JOURNAL; QUESTIONNAIRE; RADIATION CATARACT; RADIOLOGIST; SLIT LAMP; WORKLOAD;

EID: 84868232968     PISSN: 00086312     EISSN: 14219751     Source Type: Journal    
DOI: 10.1159/000342458     Document Type: Article
Times cited : (102)

References (15)
  • 1
    • 77957227354 scopus 로고    scopus 로고
    • Radiation cataract risk in interventional cardiology personnel
    • Vano E, Kleiman NJ, Duran A, et al: Radiation cataract risk in interventional cardiology personnel. Radiat Res 2010; 174: 490-495.
    • (2010) Radiat Res , vol.174 , pp. 490-495
    • Vano, E.1    Kleiman, N.J.2    Duran, A.3
  • 2
    • 77957078918 scopus 로고    scopus 로고
    • Risk for radiation induced cataract for staff in interventional cardiology: Is there reason for concern?
    • Ciraj-Bjelac O, Rehani MM, Sim KH, et al: Risk for radiation induced cataract for staff in interventional cardiology: is there reason for concern? Catheter Cardiovasc Interv 2010; 76: 826-834.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 826-834
    • Ciraj-Bjelac, O.1    Rehani, M.M.2    Sim, K.H.3
  • 3
    • 29244490039 scopus 로고    scopus 로고
    • External factors in the development of cataract
    • DOI 10.1038/sj.eye.6701964, PII 6701964
    • Robman L, Taylor H: External factors in the development of cataract. Eye 2005; 19: 1074-1082. (Pubitemid 41823766)
    • (2005) Eye , vol.19 , Issue.10 , pp. 1074-1082
    • Robman, L.1    Taylor, H.2
  • 5
    • 84870659286 scopus 로고    scopus 로고
    • International Commission on Radiological Protection Avoidance of Radiation Injuries from Medical Interventional Procedures: ICRP Publication 85 Oxford and New York, Pergamon Press, 2001
    • International Commission on Radiological Protection Avoidance of Radiation Injuries from Medical Interventional Procedures: ICRP Publication 85. Oxford and New York, Pergamon Press, 2001.
  • 6
    • 0038693131 scopus 로고    scopus 로고
    • Radiation doses to the legs of radiologists performing interventional procedures: Are they a cause for concern?
    • DOI 10.1259/bjr/65778215
    • Whitby M, Martin CJ: Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern? Br J Radiol 2003; 76: 321-327. (Pubitemid 36826740)
    • (2003) British Journal of Radiology , vol.76 , Issue.905 , pp. 321-327
    • Whitby, M.1    Martin, C.J.2
  • 7
    • 51549103141 scopus 로고    scopus 로고
    • Eye lens exposure to radiation in interventional suites: Caution is warranted
    • Vano E, Gonzalez L, Fernández JM, et al: Eye lens exposure to radiation in interventional suites: caution is warranted. Radiology 2008; 248: 945-953.
    • (2008) Radiology , vol.248 , pp. 945-953
    • Vano, E.1    Gonzalez, L.2    Fernández, J.M.3
  • 10
    • 77954195450 scopus 로고    scopus 로고
    • Scattered and staff dose levels in paediatric interventional cardiology: A multicentre study
    • Ubeda C, Vano E, Gonzalez L, et al: Scattered and staff dose levels in paediatric interventional cardiology: a multicentre study. Radiat Prot Dosim 2010; 140: 67-74.
    • (2010) Radiat Prot Dosim , vol.140 , pp. 67-74
    • Ubeda, C.1    Vano, E.2    Gonzalez, L.3
  • 11
    • 84883306271 scopus 로고    scopus 로고
    • Interventional cardiologists and risk of radiation-induced cataract: Results of a French multicenter observational study
    • E-pub ahead of print
    • Jacob S, Boveda S, Bar O, et al: Interventional cardiologists and risk of radiation-induced cataract: results of a French multicenter observational study. Int J Cardiol 2012, E-pub ahead of print.
    • (2012) Int J Cardiol
    • Jacob, S.1    Boveda, S.2    Bar, O.3
  • 12
    • 79959595834 scopus 로고    scopus 로고
    • Personal dosimetry for interventional operators: When and how should monitoring be done?
    • Martin CJ: Personal dosimetry for interventional operators: when and how should monitoring be done? Br J Radiol 2011; 84: 639-648.
    • (2011) Br J Radiol , vol.84 , pp. 639-648
    • Martin, C.J.1
  • 13
    • 0003487059 scopus 로고
    • International Commission on Radiation Units and Measurements Rep. 51, Bethesda, ICRU
    • International Commission on Radiation Units and Measurements, Quantities and Units in Radiation Protection Dosimetry, Rep. 51, Bethesda, ICRU, 1993.
    • (1993) Quantities and Units in Radiation Protection Dosimetry
  • 14
    • 65549153330 scopus 로고    scopus 로고
    • Minimizing radiation exposure to physicians performing fluoroscopically guided cardiac catheterization procedures: A review
    • Kim KP, Miller D: Minimizing radiation exposure to physicians performing fluoroscopically guided cardiac catheterization procedures: a review. Radiat Prot Dosim 2009; 133: 227-233.
    • (2009) Radiat Prot Dosim , vol.133 , pp. 227-233
    • Kim, K.P.1    Miller, D.2
  • 15
    • 78049311290 scopus 로고    scopus 로고
    • Comparing strategies for operator eye protection in the interventional radiology suite
    • Thornton RH, Dauer LT, Altamirano JP, et al: Comparing strategies for operator eye protection in the interventional radiology suite. J VascInterv Radiol 2010; 21: 1703-1707.
    • (2010) J VascInterv Radiol , vol.21 , pp. 1703-1707
    • Thornton, R.H.1    Dauer, L.T.2    Altamirano, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.