메뉴 건너뛰기




Volumn 25, Issue 12, 2012, Pages 1392-1400

The role of gray and white matter segmentation in quantitative proton MR spectroscopic imaging

Author keywords

Gray matter; Segmentation; Spectroscopic quantification MRS; White matter

Indexed keywords

ABSOLUTE QUANTIFICATION; GRAY MATTER; MEASUREMENT TIME; METABOLITE CONCENTRATIONS; MR SPECTROSCOPY; MYO-INOSITOL; N-ACETYLASPARTATE; ONE-EQUATION; PARTIAL VOLUME CORRECTION; PARTIAL VOLUME EFFECT; PARTIAL VOLUMES; SAMPLE SIZES; SPECTROSCOPIC IMAGING; SPECTROSCOPIC QUANTIFICATION MRS; STATISTICAL SIGNIFICANCE; SYSTEM OF EQUATIONS; WHITE MATTER;

EID: 84868125887     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.2812     Document Type: Article
Times cited : (64)

References (42)
  • 2
    • 56849086068 scopus 로고    scopus 로고
    • Magnetic resonance spectroscopy in neurological diagnosis
    • Tran T, Ross B, Lin A. Magnetic resonance spectroscopy in neurological diagnosis. Neurol. Clin. 2009; 27(1): 21-60.
    • (2009) Neurol. Clin. , vol.27 , Issue.1 , pp. 21-60
    • Tran, T.1    Ross, B.2    Lin, A.3
  • 3
    • 84355163075 scopus 로고    scopus 로고
    • Longitudinal inter- and intra-individual human brain metabolic quantification over 3 years with proton MR spectroscopy at 3 T
    • Kirov II, George IC, Jayawickrama N, Babb JS, Perry NN, Gonen O. Longitudinal inter- and intra-individual human brain metabolic quantification over 3 years with proton MR spectroscopy at 3 T. Magn. Reson. Med. 2011; 67(1): 27-33.
    • (2011) Magn. Reson. Med. , vol.67 , Issue.1 , pp. 27-33
    • Kirov, I.I.1    George, I.C.2    Jayawickrama, N.3    Babb, J.S.4    Perry, N.N.5    Gonen, O.6
  • 4
    • 26844563950 scopus 로고    scopus 로고
    • Integrated data acquisition and processing to determine metabolite contents, relaxation times, and macromolecule baseline in single examinations of individual subjects
    • Kreis R, Slotboom J, Hofmann L, Boesch C. Integrated data acquisition and processing to determine metabolite contents, relaxation times, and macromolecule baseline in single examinations of individual subjects. Magn. Reson. Med. 2005; 54(4): 761-768.
    • (2005) Magn. Reson. Med. , vol.54 , Issue.4 , pp. 761-768
    • Kreis, R.1    Slotboom, J.2    Hofmann, L.3    Boesch, C.4
  • 5
    • 0000927648 scopus 로고    scopus 로고
    • Quantitative localized 1H MR spectroscopy for clinical use
    • Kreis R. Quantitative localized 1H MR spectroscopy for clinical use. Prog. NMR Spectrosc. 1997; 31(2-3): 155-195.
    • (1997) Prog. NMR Spectrosc. , vol.31 , Issue.2-3 , pp. 155-195
    • Kreis, R.1
  • 7
    • 27644594658 scopus 로고    scopus 로고
    • 1H-MRS quantification of tNA and tCr in patients with multiple sclerosis: a meta-analytic review
    • Caramanos Z, Narayanan S, Arnold DL. 1H-MRS quantification of tNA and tCr in patients with multiple sclerosis: a meta-analytic review. Brain 2005; 128(11): 2483-2506.
    • (2005) Brain , vol.128 , Issue.11 , pp. 2483-2506
    • Caramanos, Z.1    Narayanan, S.2    Arnold, D.L.3
  • 8
    • 33746220435 scopus 로고    scopus 로고
    • 1H MR spectroscopy of the brain: absolute quantification of metabolites
    • Jansen JF, Backes WH, Nicolay K, Kooi ME. 1H MR spectroscopy of the brain: absolute quantification of metabolites. Radiology 2006; 240(2): 318-332.
    • (2006) Radiology , vol.240 , Issue.2 , pp. 318-332
    • Jansen, J.F.1    Backes, W.H.2    Nicolay, K.3    Kooi, M.E.4
  • 10
    • 0030229278 scopus 로고    scopus 로고
    • Noise in MRI
    • Macovski A. Noise in MRI. Magn. Reson. Med. 1996; 36(3): 494-497.
    • (1996) Magn. Reson. Med. , vol.36 , Issue.3 , pp. 494-497
    • Macovski, A.1
  • 11
    • 0034718613 scopus 로고    scopus 로고
    • Measuring the thickness of the human cerebral cortex from magnetic resonance images
    • Fischl B, Dale AM. Measuring the thickness of the human cerebral cortex from magnetic resonance images. Proc. Natl. Acad. Sci. 2000; 97(20): 11050-11055.
    • (2000) Proc. Natl. Acad. Sci. , vol.97 , Issue.20 , pp. 11050-11055
    • Fischl, B.1    Dale, A.M.2
  • 12
    • 77949663361 scopus 로고    scopus 로고
    • Reproducibility of serial whole-brain MR spectroscopic imaging
    • Maudsley AA, Domenig C, Sheriff S. Reproducibility of serial whole-brain MR spectroscopic imaging. NMR Biomed. 2010; 23: 251-256.
    • (2010) NMR Biomed. , vol.23 , pp. 251-256
    • Maudsley, A.A.1    Domenig, C.2    Sheriff, S.3
  • 13
    • 27644598162 scopus 로고    scopus 로고
    • Fast method for brain image segmentation: application to proton magnetic resonance spectroscopic imaging
    • Bonekamp D, Horska A, Jacobs MA, Arslanoglu A, Barker PB. Fast method for brain image segmentation: application to proton magnetic resonance spectroscopic imaging. Magn. Reson. Med. 2005; 54: 1268-1272.
    • (2005) Magn. Reson. Med. , vol.54 , pp. 1268-1272
    • Bonekamp, D.1    Horska, A.2    Jacobs, M.A.3    Arslanoglu, A.4    Barker, P.B.5
  • 15
    • 22944467236 scopus 로고    scopus 로고
    • Quantitative proton magnetic resonance spectroscopic imaging: regional variations in the corpus callosum and cortical gray matter
    • Degaonkar MN, Pomper MG, Barker PB. Quantitative proton magnetic resonance spectroscopic imaging: regional variations in the corpus callosum and cortical gray matter. J. Magn. Reson. Imaging 2005; 22(2): 175-179.
    • (2005) J. Magn. Reson. Imaging , vol.22 , Issue.2 , pp. 175-179
    • Degaonkar, M.N.1    Pomper, M.G.2    Barker, P.B.3
  • 16
    • 0029376733 scopus 로고
    • A fast, reliable, automatic shimming procedure using 1H chemical-shift-imaging spectroscopy
    • Hu J, Javaid T, Arias-Mendoza F, Liu Z, McNamara R, Brown TR. A fast, reliable, automatic shimming procedure using 1H chemical-shift-imaging spectroscopy. J. Magn. Res. B. 1995; 108: 213-219.
    • (1995) J. Magn. Res. B. , vol.108 , pp. 213-219
    • Hu, J.1    Javaid, T.2    Arias-Mendoza, F.3    Liu, Z.4    McNamara, R.5    Brown, T.R.6
  • 17
    • 33745685627 scopus 로고    scopus 로고
    • Optimizing the efficiency of high-field multivoxel spectroscopic imaging by multiplexing in space and time
    • Goelman G, Liu S, Hess D, Gonen O. Optimizing the efficiency of high-field multivoxel spectroscopic imaging by multiplexing in space and time. Magn. Reson. Med. 2006; 56: 34-40.
    • (2006) Magn. Reson. Med. , vol.56 , pp. 34-40
    • Goelman, G.1    Liu, S.2    Hess, D.3    Gonen, O.4
  • 18
    • 34547818284 scopus 로고    scopus 로고
    • Chemical-Shift Artifact Reduction in Hadamard-Encoded MR Spectroscopic Imaging at High (3T and 7T) Magnetic Fields
    • Goelman G, Liu S, Fleysher R, Fleysher L, Grossman RI, Gonen O. Chemical-Shift Artifact Reduction in Hadamard-Encoded MR Spectroscopic Imaging at High (3T and 7T) Magnetic Fields. Magn. Reson. Med. 2007; 58: 167-173.
    • (2007) Magn. Reson. Med. , vol.58 , pp. 167-173
    • Goelman, G.1    Liu, S.2    Fleysher, R.3    Fleysher, L.4    Grossman, R.I.5    Gonen, O.6
  • 19
  • 20
    • 0001454349 scopus 로고
    • Essential Considerations for Spectral Localization Using Indirect Gradient Encoding of Spatial Information
    • Mareci TH, Brooker HR. Essential Considerations for Spectral Localization Using Indirect Gradient Encoding of Spatial Information. J. Magn. Res. 1991; 92: 229-246.
    • (1991) J. Magn. Res. , vol.92 , pp. 229-246
    • Mareci, T.H.1    Brooker, H.R.2
  • 21
    • 33744965847 scopus 로고    scopus 로고
    • Reducing Voxel Bleed in Hadamard Encoded MRI and MRS
    • Goelman G, Liu S, Gonen O. Reducing Voxel Bleed in Hadamard Encoded MRI and MRS. Magn. Reson. Med. 2006; 55: 1460-1465.
    • (2006) Magn. Reson. Med. , vol.55 , pp. 1460-1465
    • Goelman, G.1    Liu, S.2    Gonen, O.3
  • 22
    • 0030668370 scopus 로고    scopus 로고
    • Multimodal image coregistration and partitioning--a unified framework
    • Ashburner JT, Friston KJ. Multimodal image coregistration and partitioning--a unified framework. Neuroimage 1997; 6(3): 209-217.
    • (1997) Neuroimage , vol.6 , Issue.3 , pp. 209-217
    • Ashburner, J.T.1    Friston, K.J.2
  • 23
    • 0033933649 scopus 로고    scopus 로고
    • Voxel-based morphometry--the methods
    • Ashburner JT, Friston KJ. Voxel-based morphometry--the methods. Neuroimage 2000; 11(6): 805-821.
    • (2000) Neuroimage , vol.11 , Issue.6 , pp. 805-821
    • Ashburner, J.T.1    Friston, K.J.2
  • 24
    • 0031756714 scopus 로고    scopus 로고
    • Automated spectral analysis III: application to in vivo proton MR spectroscopy and spectroscopic imaging
    • Soher BJ, Young K, Govindaraju V, Maudsley AA. Automated spectral analysis III: application to in vivo proton MR spectroscopy and spectroscopic imaging. Magn. Reson. Med. 1998; 40(6): 822-831.
    • (1998) Magn. Reson. Med. , vol.40 , Issue.6 , pp. 822-831
    • Soher, B.J.1    Young, K.2    Govindaraju, V.3    Maudsley, A.A.4
  • 26
    • 0035024163 scopus 로고    scopus 로고
    • Representation of strong baseline contributions in 1H MR spectra
    • Soher BJ, Young K, Maudsley AA. Representation of strong baseline contributions in 1H MR spectra. Magn. Reson. Med. 2001; 45(6): 966-972.
    • (2001) Magn. Reson. Med. , vol.45 , Issue.6 , pp. 966-972
    • Soher, B.J.1    Young, K.2    Maudsley, A.A.3
  • 27
    • 0037925129 scopus 로고    scopus 로고
    • Diffusely elevated cerebral choline and creatine in relapsing-remitting multiple sclerosis
    • Inglese M, Li BS, Rusinek H, Babb JS, Grossman RI, Gonen O. Diffusely elevated cerebral choline and creatine in relapsing-remitting multiple sclerosis. Magn. Reson. Med. 2003; 50(1): 190-195.
    • (2003) Magn. Reson. Med. , vol.50 , Issue.1 , pp. 190-195
    • Inglese, M.1    Li, B.S.2    Rusinek, H.3    Babb, J.S.4    Grossman, R.I.5    Gonen, O.6
  • 28
    • 53549115374 scopus 로고    scopus 로고
    • Age dependence of regional proton metabolites T2 relaxation times in the human brain at 3T
    • Kirov II, Fleysher L, Fleysher R, Patil V, Liu S, Gonen O. Age dependence of regional proton metabolites T2 relaxation times in the human brain at 3T. Magn. Reson. Med. 2008; 60(4): 790-795.
    • (2008) Magn. Reson. Med. , vol.60 , Issue.4 , pp. 790-795
    • Kirov, I.I.1    Fleysher, L.2    Fleysher, R.3    Patil, V.4    Liu, S.5    Gonen, O.6
  • 30
    • 3342939268 scopus 로고    scopus 로고
    • 1H metabolite relaxation times at 3.0 tesla: Measurements of T1 and T2 values in normal brain and determination of regional differences in transverse relaxation
    • Traber F, Block W, Lamerichs R, Gieseke J, Schild HH. 1H metabolite relaxation times at 3.0 tesla: Measurements of T1 and T2 values in normal brain and determination of regional differences in transverse relaxation. J. Magn. Reson. Imag. 2004; 19(5): 537-545.
    • (2004) J. Magn. Reson. Imag. , vol.19 , Issue.5 , pp. 537-545
    • Traber, F.1    Block, W.2    Lamerichs, R.3    Gieseke, J.4    Schild, H.H.5
  • 31
    • 73349093090 scopus 로고    scopus 로고
    • Pitfalls and advantages of different strategies for the absolute quantification of N-acetyl aspartate, creatine and choline in white and grey matter by 1H-MRS
    • Malucelli E, Manners DN, Testa C, Tonon C, Lodi R, Barbiroli B, Lotti S. Pitfalls and advantages of different strategies for the absolute quantification of N-acetyl aspartate, creatine and choline in white and grey matter by 1H-MRS. NMR Biomed. 2009; 22: 1003-1013.
    • (2009) NMR Biomed. , vol.22 , pp. 1003-1013
    • Malucelli, E.1    Manners, D.N.2    Testa, C.3    Tonon, C.4    Lodi, R.5    Barbiroli, B.6    Lotti, S.7
  • 32
    • 0029004591 scopus 로고
    • Relative concentrations of proton mr visible neurochemicals in gray and white matter in human brain
    • Doyle TJ, Bedell BJ, Narayana PA. Relative concentrations of proton mr visible neurochemicals in gray and white matter in human brain. Magn. Reson. Med. 1995; 33: 755-759.
    • (1995) Magn. Reson. Med. , vol.33 , pp. 755-759
    • Doyle, T.J.1    Bedell, B.J.2    Narayana, P.A.3
  • 33
    • 77950617072 scopus 로고    scopus 로고
    • Whole-brain proton mr spectroscopic imaging of mild-to-moderate traumatic brain injury and correlation with neuropsychological deficits
    • Govind V, Gold S, Kaliannan K, Saigal G, Falcone S, Arheart KL, Harris L, Jagid J, Maudsley AA. Whole-brain proton mr spectroscopic imaging of mild-to-moderate traumatic brain injury and correlation with neuropsychological deficits. J. Neurotrauma 2010; 27: 483-496.
    • (2010) J. Neurotrauma , vol.27 , pp. 483-496
    • Govind, V.1    Gold, S.2    Kaliannan, K.3    Saigal, G.4    Falcone, S.5    Arheart, K.L.6    Harris, L.7    Jagid, J.8    Maudsley, A.A.9
  • 34
    • 78651354281 scopus 로고    scopus 로고
    • A longitudinal proton magnetic resonance spectroscopy study of mild traumatic brain injury
    • Yeo RA, Gasparovic C, Merideth F, Ruhl D, Doezema D, Mayer AR. A longitudinal proton magnetic resonance spectroscopy study of mild traumatic brain injury. J. Neurotrauma 2011; 28: 1-11.
    • (2011) J. Neurotrauma , vol.28 , pp. 1-11
    • Yeo, R.A.1    Gasparovic, C.2    Merideth, F.3    Ruhl, D.4    Doezema, D.5    Mayer, A.R.6
  • 36
    • 33845268276 scopus 로고    scopus 로고
    • Concentrations and magnetization transfer ratios of metabolites in gray and white matter
    • McLean MA, Barker GJ. Concentrations and magnetization transfer ratios of metabolites in gray and white matter. Magn. Reson. Med. 2006; 56: 1365-1370.
    • (2006) Magn. Reson. Med. , vol.56 , pp. 1365-1370
    • McLean, M.A.1    Barker, G.J.2
  • 37
    • 0031821719 scopus 로고    scopus 로고
    • Quantitative spectroscopic imaging of the human brain
    • Pan JW, Twieg DB, Hetherington HP. Quantitative spectroscopic imaging of the human brain. Magn. Reson. Med. 1998; 40: 363-369.
    • (1998) Magn. Reson. Med. , vol.40 , pp. 363-369
    • Pan, J.W.1    Twieg, D.B.2    Hetherington, H.P.3
  • 39
    • 0242580198 scopus 로고    scopus 로고
    • Metabolite ratios to assumed stable creatine level may confound the quantification of proton brain MR spectroscopy
    • Li BS, Wang H, Gonen O. Metabolite ratios to assumed stable creatine level may confound the quantification of proton brain MR spectroscopy. Magn. Reson. Imag. 2003; 21(8): 923-928.
    • (2003) Magn. Reson. Imag. , vol.21 , Issue.8 , pp. 923-928
    • Li, B.S.1    Wang, H.2    Gonen, O.3
  • 40
    • 0031726335 scopus 로고    scopus 로고
    • Quantification of white matter and gray matter volumes from three dimensional magnetic resonance volume studies using fuzzy classifiers
    • Herndon RC, Lancaster JL, Giedd JN, Fox PT. Quantification of white matter and gray matter volumes from three dimensional magnetic resonance volume studies using fuzzy classifiers. J. Magn. Reson. Imag. 1998; 8(5): 1097-1105.
    • (1998) J. Magn. Reson. Imag. , vol.8 , Issue.5 , pp. 1097-1105
    • Herndon, R.C.1    Lancaster, J.L.2    Giedd, J.N.3    Fox, P.T.4
  • 41
    • 0036735848 scopus 로고    scopus 로고
    • Age-related total gray matter and white matter changes in normal adult brain. Part II: quantitative magnetization transfer ratio histogram analysis
    • Ge Y, Grossman RI, Babb JS, Rabin ML, Mannon LJ, Kolson DL. Age-related total gray matter and white matter changes in normal adult brain. Part II: quantitative magnetization transfer ratio histogram analysis. Am. J. Neuroradiol. 2002; 23(8): 1334-1341.
    • (2002) Am. J. Neuroradiol. , vol.23 , Issue.8 , pp. 1334-1341
    • Ge, Y.1    Grossman, R.I.2    Babb, J.S.3    Rabin, M.L.4    Mannon, L.J.5    Kolson, D.L.6
  • 42
    • 0031985750 scopus 로고    scopus 로고
    • Regional metabolite concentrations in human brain as determined by quantitative localized proton MRS
    • Pouwels PJW, Frahm J. Regional metabolite concentrations in human brain as determined by quantitative localized proton MRS. Magn. Reson. Med. 1998; 39(1): 53-60.
    • (1998) Magn. Reson. Med. , vol.39 , Issue.1 , pp. 53-60
    • Pouwels, P.J.W.1    Frahm, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.