메뉴 건너뛰기




Volumn 174, Issue , 2012, Pages 237-244

New Schiff base-carbon nanotube-nanosilica-ionic liquid as a high performance sensing material of a potentiometric sensor for nanomolar determination of cerium(III) ions

Author keywords

Carbon paste electrode; Ce(III); Ionic liquids; Multi walled carbon nanotubes; Nanosilica; Potentiometric sensor

Indexed keywords

ALKALINE EARTH; CARBON COMPOSITES; CARBON PASTE ELECTRODE; DETECTION LIMITS; ELECTROCHEMICAL RESPONSE; ELECTROCHEMICAL SENSING; FAST RESPONSE; GRAPHITE POWDER; NANO-SILICA; NANOMOLAR; PH RANGE; REAL SAMPLES; SCHIFF-BASE; SENSING MATERIAL; SILICA NANOPARTICLES; SYNTHESIZED SCHIFF; WIDE-LINEAR RANGE;

EID: 84868125796     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.07.116     Document Type: Article
Times cited : (86)

References (43)
  • 1
    • 84950218991 scopus 로고    scopus 로고
    • Environmental analysis of cerium using N-p-chlorophenyl-2- furylacrylohydroxamic acid with or without 1-(2-pyridylazo)-2-naphthol
    • S.A. Abbasi Environmental analysis of cerium using N-p-chlorophenyl-2- furylacrylohydroxamic acid with or without 1-(2-pyridylazo)-2-naphthol International Journal of Environment Analytical Chemistry 34 1998 181 190
    • (1998) International Journal of Environment Analytical Chemistry , vol.34 , pp. 181-190
    • Abbasi, S.A.1
  • 3
    • 0000995443 scopus 로고
    • Preconcentration and determination of Ce, la and Pr by X-ray fluorescence analysis, using Amberlite XAD resins loaded with 8-quinolinol and 2-(2-(5-chloropyridylazo)-5-dimethylamino)-phenol
    • A.N. Masi, and R.A. Olsina Preconcentration and determination of Ce, La and Pr by X-ray fluorescence analysis, using Amberlite XAD resins loaded with 8-quinolinol and 2-(2-(5-chloropyridylazo)-5-dimethylamino)-phenol Talanta 40 1993 931 934
    • (1993) Talanta , vol.40 , pp. 931-934
    • Masi, A.N.1    Olsina, R.A.2
  • 4
    • 0000721179 scopus 로고
    • Determination of cerium, yttrium and thorium in environmental samples
    • M. Achilli, G. Ciceri, R. Ferraroli, D. Helati, and W. Martinotti Determination of cerium, yttrium and thorium in environmental samples Analyst 114 1989 319 323
    • (1989) Analyst , vol.114 , pp. 319-323
    • Achilli, M.1    Ciceri, G.2    Ferraroli, R.3    Helati, D.4    Martinotti, W.5
  • 5
    • 0030992997 scopus 로고    scopus 로고
    • A rapid, selective and sensitive spectrophotometric method for the determination of Ce(III) using some bisazophenyl-β-diketone derivatives
    • DOI 10.1016/S0039-9140(96)02011-5, PII S0039914096020115
    • A.S. Amin, M.M. Monstafa, and R.M. Issa A rapid, selective and sensitive spectrophotometric method for the determination of Ce(III) using some bisazophenyl-β-diketone derivatives Talanta 44 1997 311 317 (Pubitemid 27176767)
    • (1997) Talanta , vol.44 , Issue.3 , pp. 311-317
    • Amin, A.S.1    Moustafa, M.M.2    Issa, R.M.3
  • 6
  • 7
    • 70349865318 scopus 로고    scopus 로고
    • Room temperature ionic liquids (RTILs) and multiwalled carbon nanotubes (MWCNTs) as modifiers for improvement of carbon paste ion selective electrode response: A comparison study with PVC membrane
    • M.R. Ganjali, H. Khoshsafar, F. Faridbod, A. Shirzadmehr, M. Javanbakht, and P. Norouzi Room temperature ionic liquids (RTILs) and multiwalled carbon nanotubes (MWCNTs) as modifiers for improvement of carbon paste ion selective electrode response: a comparison study with PVC membrane Electroanalysis 21 2009 2175 2178
    • (2009) Electroanalysis , vol.21 , pp. 2175-2178
    • Ganjali, M.R.1    Khoshsafar, H.2    Faridbod, F.3    Shirzadmehr, A.4    Javanbakht, M.5    Norouzi, P.6
  • 8
    • 70149095973 scopus 로고    scopus 로고
    • Improvement of carbon paste ion selective electrode response by using room temperature ionic liquids (RTILs) and multi-walled carbon nanotubes (MWCNTs)
    • M.R. Ganjali, H. Khoshsafar, A. Shirzadmehr, M. Javanbakht, and F. Faridbod Improvement of carbon paste ion selective electrode response by using room temperature ionic liquids (RTILs) and multi-walled carbon nanotubes (MWCNTs) International Journal of Electrochemical Science 4 2009 435 443
    • (2009) International Journal of Electrochemical Science , vol.4 , pp. 435-443
    • Ganjali, M.R.1    Khoshsafar, H.2    Shirzadmehr, A.3    Javanbakht, M.4    Faridbod, F.5
  • 10
    • 84867979873 scopus 로고    scopus 로고
    • A selective sensor for nano level detection of lead(II) in hazardous wastes using ionic-liquid/Schiff base/MWCNTs/nanosilica as a highly sensitive composite
    • doi:10.1007/s11581-012-0689-9
    • A. Afkhami, T. Madrakian, A. Shirzadmehr, H. Bagheri, M. Tabatabaee, A selective sensor for nano level detection of lead(II) in hazardous wastes using ionic-liquid/Schiff base/MWCNTs/nanosilica as a highly sensitive composite, Ionics, http://dx.doi.org/10.1007/s11581-012-0689-9.
    • Ionics
    • Afkhami, A.1    Madrakian, T.2    Shirzadmehr, A.3    Bagheri, H.4    Tabatabaee, M.5
  • 11
    • 84860714040 scopus 로고    scopus 로고
    • Multiwalled carbon nanotube paste electrode as an easy, inexpensive and highly selective sensor for voltammetric determination of Risperidone
    • A. Afkhami, and H. Ghaedi Multiwalled carbon nanotube paste electrode as an easy, inexpensive and highly selective sensor for voltammetric determination of Risperidone Analytical Methods 4 2012 1415 1420
    • (2012) Analytical Methods , vol.4 , pp. 1415-1420
    • Afkhami, A.1    Ghaedi, H.2
  • 13
    • 84857995062 scopus 로고    scopus 로고
    • Construction of a chemically modified electrode for the selective determination of nitrite and nitrate ions based on a new nanocomposite
    • A. Afkhami, T. Madrakian, H. Ghaedi, and H. Khanmohammadi Construction of a chemically modified electrode for the selective determination of nitrite and nitrate ions based on a new nanocomposite Electrochimica Acta 66 2012 255 264
    • (2012) Electrochimica Acta , vol.66 , pp. 255-264
    • Afkhami, A.1    Madrakian, T.2    Ghaedi, H.3    Khanmohammadi, H.4
  • 14
    • 51649100721 scopus 로고    scopus 로고
    • Sensors for 5-hydroxytryptamine and 5-hydroxyindole acetic acid based on nanomaterial modified electrodes
    • R.N. Goyal, M. Oyama, V.K. Gupta, S.P. Singh, and R.A. Sharma Sensors for 5-hydroxytryptamine and 5-hydroxyindole acetic acid based on nanomaterial modified electrodes Sensors and Actuators B 134 2008 816 821
    • (2008) Sensors and Actuators B , vol.134 , pp. 816-821
    • Goyal, R.N.1    Oyama, M.2    Gupta, V.K.3    Singh, S.P.4    Sharma, R.A.5
  • 15
    • 58149382234 scopus 로고    scopus 로고
    • Carbon paste electrodes in facts, numbers, and notes: A review on the occasion of the 50-years jubilee of carbon paste in electrochemistry and electroanalysis
    • I. Svancara, K. Vytras, K. Kalcher, A. Walcarius, and J. Wang Carbon paste electrodes in facts, numbers, and notes: a review on the occasion of the 50-years jubilee of carbon paste in electrochemistry and electroanalysis Electroanalysis 21 2009 7 28
    • (2009) Electroanalysis , vol.21 , pp. 7-28
    • Svancara, I.1    Vytras, K.2    Kalcher, K.3    Walcarius, A.4    Wang, J.5
  • 17
    • 84856223765 scopus 로고    scopus 로고
    • Construction of a modified carbon paste electrode for the highly selective simultaneous electrochemical determination of trace amounts of mercury(II) and cadmium(II)
    • A. Afkhami, T. Madrakian, S.J. Sabounchei, M. Rezaei, S. Samiee, and M. Pourshahbaz Construction of a modified carbon paste electrode for the highly selective simultaneous electrochemical determination of trace amounts of mercury(II) and cadmium(II) Sensors and Actuators B 161 2012 542 548
    • (2012) Sensors and Actuators B , vol.161 , pp. 542-548
    • Afkhami, A.1    Madrakian, T.2    Sabounchei, S.J.3    Rezaei, M.4    Samiee, S.5    Pourshahbaz, M.6
  • 18
    • 33744902611 scopus 로고    scopus 로고
    • High-performance carbon composite electrode based on an ionic liquid as a binder
    • DOI 10.1021/ac060070+
    • N. Maleki, A. Safavi, and F. Tajabadi High-performance carbon composite electrode based on an ionic liquid as a binder Analytical Chemistry 78 2006 3820 3826 (Pubitemid 43848978)
    • (2006) Analytical Chemistry , vol.78 , Issue.11 , pp. 3820-3826
    • Maleki, N.1    Safavi, A.2    Tajabadi, F.3
  • 19
    • 84861344967 scopus 로고    scopus 로고
    • Nernst-Planck/Poisson model for the potential response of permselective gold nanopores
    • I. Makra, G. Jagerszki, I. Bitter, and R.E. Gyurcsanyi Nernst-Planck/Poisson model for the potential response of permselective gold nanopores Electrochimica Acta 73 2012 70 77
    • (2012) Electrochimica Acta , vol.73 , pp. 70-77
    • Makra, I.1    Jagerszki, G.2    Bitter, I.3    Gyurcsanyi, R.E.4
  • 20
    • 66149085264 scopus 로고    scopus 로고
    • Limitations of current polarization for lowering the detection limit of potentiometric polymeric membrane sensors
    • L. Höfler, I. Bedlechowicz, T. Vigassy, R.E. Gyurcsanyi, E. Bakker, and E. Pretsch Limitations of current polarization for lowering the detection limit of potentiometric polymeric membrane sensors Analytical Chemistry 81 2009 3592 3599
    • (2009) Analytical Chemistry , vol.81 , pp. 3592-3599
    • Höfler, L.1    Bedlechowicz, I.2    Vigassy, T.3    Gyurcsanyi, R.E.4    Bakker, E.5    Pretsch, E.6
  • 22
    • 84861907751 scopus 로고    scopus 로고
    • Potentiometric determination of nanomolar concentration of Cu(II) using a carbon paste electrode modified by a self-assembled mercapto compound on gold nanoparticles
    • M.H. Mashhadizadeh, S. Ramezani, and S. Ebrahimi Potentiometric determination of nanomolar concentration of Cu(II) using a carbon paste electrode modified by a self-assembled mercapto compound on gold nanoparticles Sensors and Actuators B 169 2012 305 311
    • (2012) Sensors and Actuators B , vol.169 , pp. 305-311
    • Mashhadizadeh, M.H.1    Ramezani, S.2    Ebrahimi, S.3
  • 23
    • 39449110385 scopus 로고    scopus 로고
    • Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers
    • DOI 10.1021/ac071156l
    • G.A. Crespo, S. Macho, and F.X. Rius Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers Analytical Chemistry 80 2008 1316 1322 (Pubitemid 351272370)
    • (2008) Analytical Chemistry , vol.80 , Issue.4 , pp. 1316-1322
    • Crespo, G.A.1    Macho, S.2    Rius, F.X.3
  • 24
    • 0035957717 scopus 로고    scopus 로고
    • Engineering carbon nanotubes and nanotube circuits using electrical breakdown
    • DOI 10.1126/science.1058782
    • P.G. Collins, M.S. Arnold, and P. Avouris Engineering carbon nanotubes and nanotube circuits using electrical breakdown Science 292 2001 706 709 (Pubitemid 32385537)
    • (2001) Science , vol.292 , Issue.5517 , pp. 706-709
    • Collins, P.G.1    Arnold, M.S.2    Avouris, P.3
  • 25
    • 64349107262 scopus 로고    scopus 로고
    • Transduction mechanism of carbon nanotubes in solid-contact ion-selective electrodes
    • G.A. Crespo, S. Macho, J. Bobacka, and F.X. Rius Transduction mechanism of carbon nanotubes in solid-contact ion-selective electrodes Analytical Chemistry 81 2009 676 681
    • (2009) Analytical Chemistry , vol.81 , pp. 676-681
    • Crespo, G.A.1    MacHo, S.2    Bobacka, J.3    Rius, F.X.4
  • 26
    • 0036924402 scopus 로고    scopus 로고
    • Carbon nanotubes: Synthesis, integration, and properties
    • H. Dai Carbon nanotubes: synthesis, integration, and properties Accounts of Chemical Research 35 2002 1035 1044
    • (2002) Accounts of Chemical Research , vol.35 , pp. 1035-1044
    • Dai, H.1
  • 27
    • 70349328448 scopus 로고    scopus 로고
    • Ion-selective electrodes using multi walled carbon nanotubes as ion-to-electron transducers for the detection of perchlorate
    • E.J. Parra, G.A. Crespo, J. Riu, A. Ruizb, and F.X. Rius Ion-selective electrodes using multi walled carbon nanotubes as ion-to-electron transducers for the detection of perchlorate Analyst 134 2009 1905 1910
    • (2009) Analyst , vol.134 , pp. 1905-1910
    • Parra, E.J.1    Crespo, G.A.2    Riu, J.3    Ruizb, A.4    Rius, F.X.5
  • 28
    • 0000395921 scopus 로고
    • Complexes of zinc, cadmium and mercury(II) with the zwitter-ionic form of NN′-ethylenebis (salicylideneimine)
    • H.A.T. Rihai Complexes of zinc, cadmium and mercury(II) with the zwitter-ionic form of NN′-ethylenebis (salicylideneimine) Polyhedron 2 1983 723 726
    • (1983) Polyhedron , vol.2 , pp. 723-726
    • Rihai, H.A.T.1
  • 29
    • 0032153938 scopus 로고    scopus 로고
    • Cationic group 13 complexes
    • PII S0010854598001271
    • D.A. Atwood Cationic group 13 complexes Coordination Chemistry Reviews 176 1998 407 430 (Pubitemid 128452186)
    • (1998) Coordination Chemistry Reviews , vol.176 , Issue.1 , pp. 407-430
    • Atwood, D.A.1
  • 31
    • 33847119398 scopus 로고    scopus 로고
    • Solvent-free microwave synthesis of (aryland heteroaryl-methylene)-amino derivatives of 4-amino-6-methyl-5-oxo-3-thioxo-2H-1,2,4-triazine and 4-amino-5-methyl-3-thioxo-2H-1,2,4-triazole: Crystal structure of 6-methyl-4-(3-nitrobenzylideneamino)-5-oxo-3-thioxo-2H-1,2,4-triazine
    • M. Tabatabaee, M. Ghassemzadeh, B. Zarabi, M.M. Heravi, M. Anary-Abbasinejad, and B. Neumüller Solvent-free microwave synthesis of (aryland heteroaryl-methylene)-amino derivatives of 4-amino-6-methyl-5-oxo-3- thioxo-2H-1,2,4-triazine and 4-amino-5-methyl-3-thioxo-2H-1,2,4-triazole: crystal structure of 6-methyl-4-(3-nitrobenzylideneamino)-5-oxo-3-thioxo-2H-1,2, 4-triazine Phosphorus, Sulfur, and Silicon and the Related Elements 182 2007 677 686
    • (2007) Phosphorus, Sulfur, and Silicon and the Related Elements , vol.182 , pp. 677-686
    • Tabatabaee, M.1    Ghassemzadeh, M.2    Zarabi, B.3    Heravi, M.M.4    Anary-Abbasinejad, M.5    Neumüller, B.6
  • 32
    • 79954555426 scopus 로고    scopus 로고
    • Fast and efficient method for imination of N-aminorhodanine using inorganic solid support under microwave irradiation and classical heating
    • M. Tabatabaee, M.M. Heravi, M. Sharif, and F. Esfandiyari Fast and efficient method for imination of N-aminorhodanine using inorganic solid support under microwave irradiation and classical heating European Journal of Chemistry 8 2011 535 540
    • (2011) European Journal of Chemistry , vol.8 , pp. 535-540
    • Tabatabaee, M.1    Heravi, M.M.2    Sharif, M.3    Esfandiyari, F.4
  • 34
    • 84858698734 scopus 로고    scopus 로고
    • Sensitive voltammetric determination of epinephrine in the presence of acetaminophen at a novel ionic liquid modified carbon nanotubes paste electrode
    • T. Tavana, M.A. Khalilzadeh, H. Karimi-Maleh, A.A. Ensafi, H. Beitollahi, and D. Zareyee Sensitive voltammetric determination of epinephrine in the presence of acetaminophen at a novel ionic liquid modified carbon nanotubes paste electrode Journal of Molecular Liquids 168 2012 69 74
    • (2012) Journal of Molecular Liquids , vol.168 , pp. 69-74
    • Tavana, T.1    Khalilzadeh, M.A.2    Karimi-Maleh, H.3    Ensafi, A.A.4    Beitollahi, H.5    Zareyee, D.6
  • 35
    • 84876596105 scopus 로고
    • Selectivity coefficients for methods for reporting KCd, Mpot values ion-selective electrodes: Recommended
    • Y. Umezawa, K. Umezawa, and H. Sato Selectivity coefficients for methods for reporting KCd, Mpot values ion-selective electrodes: recommended Pure and Applied Chemistry 67 1995 507 518
    • (1995) Pure and Applied Chemistry , vol.67 , pp. 507-518
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3
  • 36
    • 34047129318 scopus 로고    scopus 로고
    • Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II)
    • DOI 10.1016/j.aca.2007.03.014, PII S0003267007004965
    • V.K. Gupta, A.K. Singh, M. Al Khayat, and B. Gupta Neutral carriers based polymeric membrane electrodes for selective determination of mercury(II) Analytica Chimica Acta 590 2007 81 90 (Pubitemid 46528388)
    • (2007) Analytica Chimica Acta , vol.590 , Issue.1 , pp. 81-90
    • Gupta, V.K.1    Singh, A.K.2    Al Khayat, M.3    Gupta, B.4
  • 37
    • 58149505714 scopus 로고    scopus 로고
    • Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases
    • V.K. Gupta, M. Al Khayat, A.K. Singha, and M.K. Pal Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases Analytica Chimica Acta 634 2009 36 43
    • (2009) Analytica Chimica Acta , vol.634 , pp. 36-43
    • Gupta, V.K.1    Al Khayat, M.2    Singha, A.K.3    Pal, M.K.4
  • 38
    • 0001498689 scopus 로고    scopus 로고
    • A PVC-Based Benzo-15-Crown-5 Membrane Sensor for Cadmium
    • S.K. Srivastava, V.K. Gupta, and S. Juin A PVC-based benzo-15-crown-5 membrane sensor for cadmium Electroanalysis 8 1996 938 940 (Pubitemid 126419469)
    • (1996) Electroanalysis , vol.8 , Issue.10 , pp. 938-940
    • Srivastava, S.K.1    Gupta, V.K.2    Jain, S.3
  • 41
    • 33746364818 scopus 로고    scopus 로고
    • A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of NN-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine
    • V.K. Gupta, A.K. Singh, and B. Gupta A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of NN-bis[2- (salicylideneamino)ethyl]ethane-1,2-diamine Analytica Chimica Acta 575 2006 198 204
    • (2006) Analytica Chimica Acta , vol.575 , pp. 198-204
    • Gupta, V.K.1    Singh, A.K.2    Gupta, B.3
  • 42
    • 77957334330 scopus 로고    scopus 로고
    • Cerium(III)-selective membrane electrode based on dibenzo-24-crown-8 as a neutral carrier
    • S.K. Mittal, S.K. Ashok Kumar, and H.K. Sharma Cerium(III)-selective membrane electrode based on dibenzo-24-crown-8 as a neutral carrier European Journal of Chemistry 7 2010 849 855
    • (2010) European Journal of Chemistry , vol.7 , pp. 849-855
    • Mittal, S.K.1    Ashok Kumar, S.K.2    Sharma, H.K.3
  • 43
    • 0034213926 scopus 로고    scopus 로고
    • PVC-based 1,3,5-trithiane sensor for cerium(III) ions
    • DOI 10.1021/ac991155w
    • M. Shamsipur, M. Yousefi, and M.R. Ganjali PVC-based 1,3,5-trithiane sensor for cerium(III) ions Analytical Chemistry 72 2000 2391 2394 (Pubitemid 30395637)
    • (2000) Analytical Chemistry , vol.72 , Issue.11 , pp. 2391-2394
    • Shamsipur, M.1    Yousefi, M.2    Ganjali, M.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.