메뉴 건너뛰기




Volumn 14, Issue 11, 2012, Pages 1013-1017

Comparison of insulin infusion protocols targeting 110-140mg/dL in patients after cardiac surgery

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; INSULIN;

EID: 84868025087     PISSN: 15209156     EISSN: 15578593     Source Type: Journal    
DOI: 10.1089/dia.2012.0114     Document Type: Article
Times cited : (8)

References (16)
  • 4
    • 3442899889 scopus 로고    scopus 로고
    • Effect of an intensive glucose management protocol on the mortality of critically Ill adult patients
    • Krinsley JS: Effect of an intensive glucose management protocol on the mortality of critically ill adult patients. Mayo Clin Proc 2004;79:992-1000. (Pubitemid 39007018)
    • (2004) Mayo Clinic Proceedings , vol.79 , Issue.8 , pp. 992-1000
    • Krinsley, J.S.1
  • 6
    • 50449103607 scopus 로고    scopus 로고
    • Benefits and risks of tight glucose control in critically ill adults: A meta-analysis
    • Wiener RS, Wiener DC, Larson RJ: Benefits and risks of tight glucose control in critically ill adults: a meta-analysis. JAMA 2008;300:933-944.
    • (2008) JAMA , vol.300 , pp. 933-944
    • Wiener, R.S.1    Wiener, D.C.2    Larson, R.J.3
  • 9
    • 66549097705 scopus 로고    scopus 로고
    • American association of clinical endocrinologists; American diabetes association: American association of clinical endocrinologists and american diabetes association consensus statement on inpatient glycemic control
    • Moghissi ES, Korytkowski MT, DiNardo M, Einhorn D, Hellman R, Hirsch IB, Inzucchi SE, Ismail-Beigi F, Kirkman MS, Umpierrez GE; American Association of Clinical Endocrinologists; American Diabetes Association: American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control. Diabetes Care 2009;32:1119-1131.
    • (2009) Diabetes Care , vol.32 , pp. 1119-1131
    • Moghissi, E.S.1    Korytkowski, M.T.2    Dinardo, M.3    Einhorn, D.4    Hellman, R.5    Hirsch, I.B.6    Inzucchi, S.E.7    Ismail-Beigi, F.8    Kirkman, M.S.9    Umpierrez, G.E.10
  • 10
    • 78651338445 scopus 로고    scopus 로고
    • Standards of medical care for patients with diabetes mellitus - 2011
    • American Diabetes Association
    • American Diabetes Association: Standards of medical care for patients with diabetes mellitus - 2011. Diabetes Care 2011;34(Suppl 1):S11-S61.
    • (2011) Diabetes Care , vol.34 , Issue.SUPPL. 1
  • 11
    • 84861076097 scopus 로고    scopus 로고
    • Adapting to the new consensus guidelines for managing hyperglycemia during critical illness: The updated Yale insulin infusion protocol
    • Shetty S, Inzucchi SE, Goldberg PA, Cooper DA, Siegel MD, Honiden S: Adapting to the new consensus guidelines for managing hyperglycemia during critical illness: the updated Yale insulin infusion protocol. Endcocr Pract 2012;18: 363-370.
    • (2012) Endcocr Pract , vol.18 , pp. 363-370
    • Shetty, S.1    Inzucchi, S.E.2    Goldberg, P.A.3    Cooper, D.A.4    Siegel, M.D.5    Honiden, S.6
  • 12
    • 76749112027 scopus 로고    scopus 로고
    • Comparisons of different insulin infusion protocols: A review of recent literature
    • Krikorian A, Ismail-Beigi F, Moghissi ES: Comparisons of different insulin infusion protocols: a review of recent literature. Curr Opin Clin Nutr Metab Care 2010;13:198-204.
    • (2010) Curr Opin Clin Nutr Metab Care , vol.13 , pp. 198-204
    • Krikorian, A.1    Ismail-Beigi, F.2    Moghissi, E.S.3
  • 15
    • 33846681947 scopus 로고    scopus 로고
    • Glucose measurement: Confounding issues in setting targets for inpatient management
    • DOI 10.2337/dc06-1679
    • Dungan K, Chapman J, Braithwaite SS, Buse J: Glucose measurement: confounding issues in setting targets for inpatient management. Diabetes Care 2007;30:403-409. (Pubitemid 46198356)
    • (2007) Diabetes Care , vol.30 , Issue.2 , pp. 403-409
    • Dungan, K.1    Chapman, J.2    Braithwaite, S.S.3    Buse, J.4
  • 16
    • 0033574249 scopus 로고    scopus 로고
    • A more accurate method to estimate glomerular filtration rate from serum creatinine: A new prediction equation
    • Levey AS, Bosch JP, Lewis JB, Greene T, Rogers N, Roth D: A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Ann Intern Med 1999;130:461-470. (Pubitemid 29135798)
    • (1999) Annals of Internal Medicine , vol.130 , Issue.6 , pp. 461-470
    • Levey, A.S.1    Bosch, J.P.2    Lewis, J.B.3    Greene, T.4    Rogers, N.5    Roth, D.6