메뉴 건너뛰기




Volumn 27, Issue 4, 2012, Pages 1969-1977

Assessment and choice of input signals for multiple HVDC and FACTS wide-area damping controllers

Author keywords

Flexible ac transmission system (FACTS); high voltage direct current (HVDC) transmission; inter area oscillations; relative gain array (RGA); residue analysis; wide area damping controllers (WADCs)

Indexed keywords

DAMPING CONTROLLERS; FLEXIBLE AC TRANSMISSION SYSTEM; HIGH VOLTAGE DIRECT CURRENT; INTER-AREA OSCILLATIONS; RELATIVE GAIN ARRAY; RESIDUE ANALYSIS;

EID: 84867995104     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2012.2189865     Document Type: Article
Times cited : (76)

References (14)
  • 3
    • 79951523801 scopus 로고    scopus 로고
    • Robust high-voltage direct current stabilising control using wide-area measurement and taking transmission time delay into consideration
    • Mar
    • Y. Li, C. Rehtanz, D. C. Yang, S. Rüberg, and U. Häger, "Robust high-voltage direct current stabilising control using wide-area measurement and taking transmission time delay into consideration," IET Gen., Transm., Distrib., vol. 5, no. 3, pp. 289-297, Mar. 2011.
    • (2011) IET Gen., Transm., Distrib , vol.5 , Issue.3 , pp. 289-297
    • Li, Y.1    Rehtanz, C.2    Yang, D.C.3    Rüberg, S.4    Häger, U.5
  • 4
    • 34248512639 scopus 로고    scopus 로고
    • Optimal wide area controller and state predictor for a power system
    • DOI 10.1109/TPWRS.2007.895158
    • S. Mohagheghi, G. K. Venayagamoorthy, and R. G. Harley, "Optimal wide area controller and state predictor for a power sytsem," IEEE Trans. Power Syst., vol. 22, no. 2, pp. 693-705, May 2007. (Pubitemid 46746232)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.2 , pp. 693-705
    • Mohagheghi, S.1    Venayagamoorthy, G.K.2    Harley, R.G.3
  • 5
    • 84894028881 scopus 로고    scopus 로고
    • Design and experiment of wide area HVDC supplementary damping controller considering time delay in China southern power grid
    • Jan
    • J. He, C. Lu, X.Wu, P. Li, and J.Wu, "Design and experiment of wide area HVDC supplementary damping controller considering time delay in China southern power grid," IET Gen., Transm., Distrib., vol. 3, no. 1, pp. 17-25, Jan. 2009.
    • (2009) IET Gen., Transm., Distrib , vol.3 , Issue.1 , pp. 17-25
    • He, J.1    Lu, C.2    Wu, X.3    Li, P.4    Wu, J.5
  • 7
    • 43849095926 scopus 로고    scopus 로고
    • Assessment of two methods to select wide-area signals for power system damping control
    • DOI 10.1109/TPWRS.2008.919240
    • A. Heniche and I.Kamwa, "Assessment of twomethods to selectwidearea signals for power system damping control," IEEE Trans. Power Syst., vol. 23, no. 2, pp. 572-581, May 2008. (Pubitemid 351695836)
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.2 , pp. 572-581
    • Heniche, A.1    Kamwa, I.2
  • 8
    • 2542564990 scopus 로고    scopus 로고
    • Choice of FACTS device control inputs for damping interarea oscillations
    • May
    • M. M. Farsangi, Y. H. Song, andK.Y. Lee, "Choice of FACTS device control inputs for damping interarea oscillations," IEEE Trans. Power Syst., vol. 19, no. 2, pp. 1135-1143, May 2004.
    • (2004) IEEE Trans. Power Syst , vol.19 , Issue.2 , pp. 1135-1143
    • Farsangi, M.M.1    Song, Y.H.2    Lee, K.Y.3
  • 9
    • 34548015465 scopus 로고    scopus 로고
    • Placement of SVCs and selection of stabilizing signals in power systems
    • DOI 10.1109/TPWRS.2007.901285
    • M. M. Farsangi, H. Nezamabadi-pour, Y. H. Song, and K. Y. Lee, "Placement of SVCs and selection of stabilizing signals in power systems," IEEE Trans. Power Syst., vol. 22, no. 3, pp. 1061-1071, Aug. 2007. (Pubitemid 47278365)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.3 , pp. 1061-1071
    • Farsangi, M.M.1    Nezamabadi-Pour, H.2    Song, Y.-H.3    Lee, K.Y.4
  • 11
    • 1442314508 scopus 로고    scopus 로고
    • Identification of electromechanical modes and placement of PSSs using relative gain array
    • Feb
    • J. V. Milanovic and A. C. S. Duque, "Identification of electromechanical modes and placement of PSSs using relative gain array," IEEE Trans. Power Syst., vol. 19, no. 1, pp. 410-417, Feb. 2004.
    • (2004) IEEE Trans. Power Syst , vol.19 , Issue.1 , pp. 410-417
    • Milanovic, J.V.1    Duque, A.C.S.2
  • 13
    • 77958475298 scopus 로고    scopus 로고
    • A power oscillation damping control scheme based on Bang-Bang modulation of FACTs signals
    • Nov
    • H. Nguyen-Duc, L. Dessaint, A. F. Okou, and I. Kamwa, "A power oscillation damping control scheme based on Bang-Bang modulation of FACTs signals," IEEE Trans. Power Syst., vol. 25, no. 4, pp. 1918-1927, Nov. 2010.
    • (2010) IEEE Trans. Power Syst , vol.25 , Issue.4 , pp. 1918-1927
    • Nguyen-Duc, H.1    Dessaint, L.2    Okou, A.F.3    Kamwa, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.